IOVS Advertisement
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Originally published In Press as doi:10.1167/iovs.07-1187 on June 6, 2008
(Investigative Ophthalmology and Visual Science. 2008;49:4886-4892.)
© 2008 by The Association for Research in Vision and Ophthalmology, Inc.
doi:10.1167/iovs.07-1187

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
iovs.07-1187v1
49/11/4886    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (7)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Leung, C. K.-s.
Right arrow Articles by Weinreb, R. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Leung, C. K.-s.
Right arrow Articles by Weinreb, R. N.

Longitudinal Variability of Optic Disc and Retinal Nerve Fiber Layer Measurements

Christopher Kai-shun Leung,1,2 Carol Yim-lui Cheung,1 Dusheng Lin,1,3 Chi Pui Pang,1 Dennis S. C. Lam,1 and Robert N. Weinreb2

1From the Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong, Peoples Republic of China; the 2Department of Ophthalmology, Hamilton Glaucoma Center, University of California, San Diego, California; and 3The STU/CUHK Joint Shantou International Eye Centre (JSIEC), Shantou University Medical College, Peoples Republic of China.

PURPOSE. To evaluate the longitudinal variability of optic disc and retinal nerve fiber layer (RNFL) measurements obtained from optical coherence tomography (OCT), scanning laser polarimetry (SLP), and confocal scanning laser ophthalmoscopy (CSLO).

METHODS. Forty-five normal and 43 glaucomatous eyes of 88 subjects were analyzed in this longitudinal study. RNFL thickness was measured by OCT (StatusOCT; Carl Zeiss Meditec, Dublin, CA) and SLP (GDx VCC; Carl Zeiss Meditec). Neuroretinal rim area was measured by CSLO (HRT 3; Heidelberg Engineering, GmbH, Dossenheim, Germany). Three separate measurements taken over an average period of 8.8 ± 1.2 months were used to evaluate measurement variability. Reproducibility coefficient, coefficient of variation, intraclass correlation coefficient (ICC), and sensitivity to change [(97.5 percentile value – 2.5 percentile value)/2 · within-subject standard deviation (Sw)] of the global measures were calculated. The association between RNFL and rim area measurement variability and visual field MD (mean deviation) was evaluated with regression analysis.

RESULTS. Low variability was found for global and sectorial rim area and RNFL measurements. The reproducibility coefficient, ICC, and sensitivity to change for OCT average RNFL thickness, GDx VCC TSNIT average, and HRT global rim area were 11.7 µm (95% confidence interval [CI]: 10.5–12.9 µm), 0.97 (0.96–0.98), 10.2 (9.2–11.4); 4.7 µm (4.2–5.1 µm), 0.98 (0.97–0.99), 11.3 (10.2–12.6); and 0.22 mm2 (0.19–0.24 mm2), 0.97 (0.95–0.98), 9.3 (8.4–10.4), respectively. No association was found between OCT (r = 0.010 [95% CI: –0.200–0.219], P = 0.924) and SLP (r = –0.034 [95% CI: –0.241–0.177], P = 0.756) RNFL thickness variances and visual field MD. The association between CSLO rim area variance and visual field MD became insignificant after adjustment for reference height variance.

CONCLUSIONS. Longitudinal RNFL and neuroretinal rim measurements obtained with OCT, SLP, and CSLO have low variability. As the measurement variability does not change with the severity of glaucoma, these parameters are useful for assessment of glaucoma progression.





This article has been cited by other articles:


Home page
Arch OphthalmolHome page
C. J. Scott, R. H. Kardon, A. G. Lee, L. Frisen, and M. Wall
Diagnosis and Grading of Papilledema in Patients With Raised Intracranial Pressure Using Optical Coherence Tomography vs Clinical Expert Assessment Using a Clinical Staging Scale
Arch Ophthalmol, June 1, 2010; 128(6): 705 - 711.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
C. K.-s. Leung, C. Y. L. Cheung, R. N. Weinreb, K. Qiu, S. Liu, H. Li, G. Xu, N. Fan, C. P. Pang, K. K. Tse, et al.
Evaluation of Retinal Nerve Fiber Layer Progression in Glaucoma: A Study on Optical Coherence Tomography Guided Progression Analysis
Invest. Ophthalmol. Vis. Sci., January 1, 2010; 51(1): 217 - 222.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
F. A. Medeiros, L. M. Zangwill, L. M. Alencar, C. Bowd, P. A. Sample, R. Susanna Jr, and R. N. Weinreb
Detection of Glaucoma Progression with Stratus OCT Retinal Nerve Fiber Layer, Optic Nerve Head, and Macular Thickness Measurements
Invest. Ophthalmol. Vis. Sci., December 1, 2009; 50(12): 5741 - 5748.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
D. C. Hood, S. C. Anderson, M. Wall, A. S. Raza, and R. H. Kardon
A Test of a Linear Model of Glaucomatous Structure-Function Loss Reveals Sources of Variability in Retinal Nerve Fiber and Visual Field Measurements
Invest. Ophthalmol. Vis. Sci., September 1, 2009; 50(9): 4254 - 4266.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
F. A. Medeiros, L. M. Alencar, L. M. Zangwill, C. Bowd, G. Vizzeri, P. A. Sample, and R. N. Weinreb
Detection of Progressive Retinal Nerve Fiber Layer Loss in Glaucoma Using Scanning Laser Polarimetry with Variable Corneal Compensation
Invest. Ophthalmol. Vis. Sci., April 1, 2009; 50(4): 1675 - 1681.
[Abstract] [Full Text] [PDF]


Home page
Br J OphthalmolHome page
K A Townsend, G Wollstein, and J S Schuman
Imaging of the retinal nerve fibre layer for glaucoma
Br J Ophthalmol, February 1, 2009; 93(2): 139 - 143.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the Association for Research in Vision and Ophthalmology