IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Originally published In Press as doi:10.1167/iovs.08-1921 on July 18, 2008
(Investigative Ophthalmology and Visual Science. 2008;49:5332-5339.)
© 2008 by The Association for Research in Vision and Ophthalmology, Inc.
doi:10.1167/iovs.08-1921

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
iovs.08-1921v1
49/12/5332    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ding, L.
Right arrow Articles by Huxlin, K. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ding, L.
Right arrow Articles by Huxlin, K. R.

Intratissue Refractive Index Shaping (IRIS) of the Cornea and Lens Using a Low-Pulse-Energy Femtosecond Laser Oscillator

Li Ding,1 Wayne H. Knox,1 Jens Bühren,2,3 Lana J. Nagy,2,3 and Krystel R. Huxlin2,3

1From The Institute of Optics, the 2Department of Ophthalmology, and the 3Center for Visual Science, University of Rochester, Rochester, New York.

PURPOSE. To assess the optical effect of high-repetition-rate, low-energy femtosecond laser pulses on lightly fixed corneas and lenses.

METHODS. Eight corneas and eight lenses were extracted postmortem from normal, adult cats. They were lightly fixed and stored in a solution that minimized swelling and opacification. An 800-nm Ti:Sapphire femtosecond laser oscillator with a 27-fs pulse duration and 93-MHz repetition rate was used to inscribe gratings consisting of 20 to 40 lines, each 1-µm wide, 100-µm long, and 5-µm apart, 100 µm below the tissue surface. Refractive index changes in the micromachined regions were calculated immediately and after 1 month of storage by measuring the intensity distribution of diffracted light when the gratings were irradiated with a 632.8-nm He-Ne laser.

RESULTS. Periodic gratings were created in the stromal layer of the corneas and the cortex of the lenses by adjusting the laser pulse energy until visible plasma luminescence and bubbles were no longer generated. The gratings had low scattering loss and could only be visualized using phase microscopy. Refractive index changes measured 0.005 ± 0.001 to 0.01 ± 0.001 in corneal tissue and 0.015 ± 0.001 to 0.021 ± 0.001 in the lenses. The gratings and refractive index changes were preserved after storing the micromachined corneas and lenses for 1 month.

CONCLUSIONS. These pilot experiments demonstrate a novel application of low-pulse-energy, MHz femtosecond lasers in modifying the refractive index of transparent ocular tissues without apparent tissue destruction. Although it remains to be verified in living tissues, the stability of this effect suggests that the observed modifications are due to long-term molecular and/or structural changes.





This article has been cited by other articles:


Home page
IOVSHome page
L. J. Nagy, L. Ding, L. Xu, W. H. Knox, and K. R. Huxlin
Potentiation of Femtosecond Laser Intratissue Refractive Index Shaping (IRIS) in the Living Cornea with Sodium Fluorescein
Invest. Ophthalmol. Vis. Sci., February 1, 2010; 51(2): 850 - 856.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the Association for Research in Vision and Ophthalmology