IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2008;49:820-827.)
© 2008 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.07-1004

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Connolly, D. M.
Right arrow Articles by Moorhead, I. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Connolly, D. M.
Right arrow Articles by Moorhead, I. R.

Mild Hypoxia Impairs Chromatic Sensitivity in the Mesopic Range

Desmond M. Connolly,1,2 John L. Barbur,2 Sarah L. Hosking,2 and Ian R. Moorhead1

From 1QinetiQ, Farnborough, United Kingdom; and the 2Applied Vision Research Centre, The Henry Wellcome Laboratories for Vision Sciences, City University, London, United Kingdom.

PURPOSE. The effect of mild hypoxia on chromatic sensitivity in the mesopic range is poorly documented. This study was conducted to examine the effects of mild hypoxia and hyperoxia on red-green (R-G) and yellow-blue (Y-B) chromatic sensitivity thresholds at low photopic (22.3 cd · m–2), borderline upper mesopic (1.67 cd · m–2) and mid-mesopic (0.21 cd · m–2) luminance.

METHODS. The Color Assessment and Diagnosis (CAD) test was used to measure binocular and monocular R-G and Y-B chromatic sensitivity by using dynamic luminance contrast noise to isolate the use of color signals. Mild hypoxia was imposed by breathing 14.1% oxygen and was investigated relative to control exposures breathing air (normoxia) at each light level. Subsequently, hyperoxia, breathing 100% oxygen, was assessed relative to hypoxia under the mesopic conditions. A balanced, repeated-measures design allowed assessment of main effects and interactions of light level, viewing condition, gender, breathing gas, and exposure order by using multivariate analysis of variance (MANOVA), with post hoc analysis employing ANOVA and paired t-tests.

RESULTS. Light level, number of viewing eyes, and oxygenation state were significant determinants of chromatic sensitivity. One man and one woman introduced orthogonal sources of gender bias. The CAD test revealed minimal deuteranomaly (R-G deficiency) in the man and loss of Y-B sensitivity in the only woman using hormonal contraception.

CONCLUSIONS. In the mesopic range, mild hypoxia impairs chromatic sensitivity progressively with reducing luminance. Binocular summation of chromatic signals is consistent and independent of the luminance channel. The CAD test is highly sensitive to mild congenital and acquired color vision deficiencies.








HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the Association for Research in Vision and Ophthalmology