IOVS Biophysical Journal
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2008;49:945-953.)
© 2008 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.07-1083

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bowd, C.
Right arrow Articles by Goldbaum, M. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bowd, C.
Right arrow Articles by Goldbaum, M. H.

Bayesian Machine Learning Classifiers for Combining Structural and Functional Measurements to Classify Healthy and Glaucomatous Eyes

Christopher Bowd,1 Jiucang Hao,2 Ivan M. Tavares,1 Felipe A. Medeiros,1 Linda M. Zangwill,1 Te-Won Lee,2,3 Pamela A. Sample,1 Robert N. Weinreb,1 and Michael H. Goldbaum1,4

1From the Hamilton Glaucoma Center and the 2Institute for Neural Computation, University of California, San Diego, La Jolla, California; the 3Computational Neurobiology Laboratories, The Salk Institute, La Jolla, California; and 4VA San Diego Health Services, San Diego, California.

PURPOSE. To determine whether combining structural (optical coherence tomography, OCT) and functional (standard automated perimetry, SAP) measurements as input for machine learning classifiers (MLCs; relevance vector machine, RVM; and subspace mixture of Gaussians, SSMoG) improves diagnostic accuracy for detecting glaucomatous eyes compared with using each measurement method alone.

METHODS. Sixty-nine eyes of 69 healthy control subjects (average age, 62.0, SD 9.7 years; visual field mean deviation [MD], –0.70, SD 1.41 dB) and 156 eyes of 156 patients with glaucoma (average age, 66.4, SD 10.2 years; visual field MD, –3.12, SD 3.43 dB) were imaged with OCT (Stratus OCT, Carl Zeiss Meditec, Inc., Dublin, CA) and tested with SAP (Humphrey Field Analyzer II with Swedish Interactive Thresholding Algorithm, SITA; Carl Zeiss Meditec, Inc.) within 3 months of each other. RVM and SSMoG MLCs were trained and tested on OCT-determined RNFL thickness measurements from 32 sectors (~11.25° each) obtained in the circumpapillary area under the instrument-defined measurement ellipse and SAP pattern deviation values from 52 points from the 24-2 grid, independently and in combination. Tenfold cross-validation was used to train and test classifiers on unique subsets of the full 225-eye data set, and areas under the receiver operating characteristic curve (AUROC) for the classification of eyes in the test set were generated. AUROC results from classifiers trained on OCT and SAP alone and those trained on OCT and SAP in combination were compared. In addition, these results were compared to currently available OCT measurements (mean retinal nerve fiber layer [RNFL] thickness, inferior RNFL thickness, and superior RNFL thickness) and SAP indices (MD and pattern standard deviation [PSD]).

RESULTS. The AUROCs for RVM trained on OCT parameters alone, SAP parameters alone and OCT and SAP parameters combined were 0.809, 0.815, and 0.845, respectively. The AUROCs for SSMoG trained on OCT parameters alone, SAP parameters alone, and OCT and SAP parameters combined were 0.817, 0.841, and 0.869, respectively. Combining techniques using both RVM and SSMoG significantly improved on MLC analysis of OCT, but not SAP, measurements alone. Classification performance using RVM and SSMoG was statistically similar.

CONCLUSIONS. RVM and SSMoG Bayesian MLCs trained on OCT and SAP data can successfully discriminate between healthy and early glaucomatous eyes. Combining OCT and SAP measurements using RVM and SSMoG increased diagnostic performance marginally compared with MLC analysis of data obtained using each technology alone.








HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the Association for Research in Vision and Ophthalmology