IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2008;49:1398-1406.)
© 2008 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.07-1306

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schulze, M. M.
Right arrow Articles by Simpson, T. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schulze, M. M.
Right arrow Articles by Simpson, T. L.

The Use of Fractal Analysis and Photometry to Estimate the Accuracy of Bulbar Redness Grading Scales

Marc M. Schulze,1,2 Natalie Hutchings,2 and Trefford L. Simpson1,2

1From the Centre for Contact Lens Research and the 2School of Optometry, University of Waterloo, Waterloo, Canada.

PURPOSE. To use physical attributes of redness to determine the accuracy of four bulbar redness grading scales, and to cross-calibrate the scales based on these physical measures.

METHODS. Two image-processing metrics, fractal dimension (D) and percentage of pixel coverage (% PC), as well as photometric chromaticity were selected as physical measures, to describe and compare grades of bulbar redness among the McMonnies/Chapman-Davies scale, the Efron Scale, the Institute for Eye Research scale, and a validated scale developed at the Centre for Contact Lens Research. Two sets of images were prepared by using image processing: The first included multiple segments covering the largest possible region of interest (ROI) within the bulbar conjunctiva in the original images; the second contained modified scale images that were matched in size and resolution across scales, and a single, equally-sized ROI. To measure photometric chromaticity, the original scale images were displayed on a computer monitor, and multiple conjunctival segments were analyzed. Pearson correlation coefficients between each set of image metrics and the reference image grades were calculated to determine the accuracy of the scales.

RESULTS. Correlations were high between reference image grades and all sets of objective metrics (all Pearson’s r ≥ 0.88, P ≤ 0.05); each physical attribute pointed to a different scale as being most accurate. Independent of the physical attribute used, there were wide discrepancies between scale grades, with almost no overlap when cross-calibrating and comparing the scales.

CONCLUSIONS. Despite the generally strong linear associations between the physical characteristics of reference images in each scale, the scales themselves are not inherently accurate and are too different to allow for cross-calibration.