IOVS Microbiology and Molecular Biology Reviews
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Originally published In Press as doi:10.1167/iovs.07-1127 on February 8, 2008
(Investigative Ophthalmology and Visual Science. 2008;49:1879-1885.)
© 2008 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.07-1127

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
iovs.07-1127v1
49/5/1879    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Danesh-Meyer, H. V.
Right arrow Articles by Gamble, G. D.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Danesh-Meyer, H. V.
Right arrow Articles by Gamble, G. D.

In Vivo Retinal Nerve Fiber Layer Thickness Measured by Optical Coherence Tomography Predicts Visual Recovery after Surgery for Parachiasmal Tumors

Helen V. Danesh-Meyer,1 Taras Papchenko,1 Peter J. Savino,2 Andrew Law,3 James Evans,4 and Greg D. Gamble5

1From the Departments of Ophthalmology and 5Medicine, University of Auckland, Auckland, New Zealand; 2Neuro-ophthalmology Service, Wills Eye Institute, Philadelphia, Pennsylvania; the 3Department of Neurosurgery, Auckland Hospital, Auckland, New Zealand; and the 4Department of Neurosurgery, Thomas Jefferson University, Philadelphia, Pennsylvania.

PURPOSE. Restoration of visual function after neurosurgery for parachiasmal tumors is variable and unpredictable. The current study was conducted to determine whether in vivo retinal nerve fiber layer (RNFL) thickness measurements predict the visual recovery of such patients.

METHODS. Forty patients undergoing surgical resection of parachiasmal lesions were prospectively assessed before surgery with a neuro-ophthalmic examination, involving standard automated visual field (VF) testing and optical coherence tomography (OCT) measurements of RNFL thickness, which was the prespecified marker for axonal loss. Tests were repeated within 6 weeks after surgery.

RESULTS. Thinner preoperative RNFL thickness was associated with worse visual acuity (VA) and VF mean deviation (MD). Patients with normal preoperative RNFL had significant improvement in mean VA after surgery, from 20/40 to 20/25 (P = 0.028), whereas patients with thin RNFL did not improve (20/80 to 20/60, P = 0.177). Eyes with normal RNFL showed improvement in MD (–7.0 dB before surgery, –3.5 dB after surgery, P = 0.0007) unlike eyes with thin RNFLs, which had no significant improvement after surgery (–15.3 dB before and –13.3 dB after surgery, P = 0.191). RNFL thickness increased by 1% after surgery among all eyes (P = 0.04). Eyes with severe VF defects (MD ≤ –10 dB) but normal preoperative RNFL thickness showed a postoperative improvement in MD of 14.6 dB compared with 1.6 dB (P < 0.0001) in eyes with thin RNFL before surgery, despite no difference in MD before surgery (normal RNFL MD, –22.3 dB; thin RNFL MD, –20.8 dB; P = 0.7).

CONCLUSIONS. Patients who have objectively measurable RNFL loss at the time of surgery for chiasmal compressive lesions are less likely to have return of VA or VF after surgery.








HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS