IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2008;49:2004-2008.)
© 2008 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.07-1056

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Grewal, D.
Right arrow Articles by Grewal, S. P. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Grewal, D.
Right arrow Articles by Grewal, S. P. S.

Pentacam Tomograms: A Novel Method for Quantification of Posterior Capsule Opacification

Dilraj Grewal,1,2 Rajeev Jain,1 Gagandeep Singh Brar,1 and Satinder Pal Singh Grewal1

1From the Grewal Eye Institute, Chandigarh, India; and 2Department of Ophthalmology, University of Miami Miller School of Medicine, Palm Beach Gardens, Florida.

PURPOSE. To develop and validate a method to quantify posterior capsule opacification (PCO) in eyes after cataract surgery and intraocular lens implantation using Scheimpflug Pentacam tomograms and compare its validity with slit lamp retroillumination image analysis.

METHODS. One hundred twenty-four pseudophakic eyes of 124 patients were divided into two groups. Group 1 consisted of 40 eyes with visually significant PCO, and group 2 consisted of 84 eyes without visually significant PCO. Pentacam Imaging was performed after full mydriasis using the 50-scan acquisition protocol, and high-resolution tomograms were reconstructed and analyzed using ImageJ freeware. Retroillumination photographs were captured for group 1 eyes using the Topcon digital slit lamp, and these were analyzed using POCOman software to calculate an aggregate severity grade and percentage PCO value. Correlation coefficients were calculated for PCO values obtained using POCOman and ImageJ.

RESULTS. Mean PCO percentage value obtained using POCOman software was 23.34 ± 6.25 U, mean aggregate PCO severity grade was 0.46 ± 0.28 U, and mean pixel-intensity value using ImageJ was 31.071 ± 8.26 U. There was a significant positive correlation between the percentage PCO (P = 0.000; r = 0.864) and PCO severity grade (P = 0.001; r = 0.490) obtained for group 1 eyes using slit lamp retroillumination images and PCO pixel intensity obtained using Pentacam tomograms.

CONCLUSIONS. Retroillumination photographs are the standard for quantifying PCO. Pentacam tomograms are easier to obtain and are free of flash reflections, and they allow for a more objective analysis. The correlation between the two methods demonstrates that ImageJ analysis of Pentacam tomograms is a viable tool for PCO analysis.








HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the Association for Research in Vision and Ophthalmology