IOVS Stroke
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2008;49:2134-2142.)
© 2008 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.07-0933

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nolan, J. M.
Right arrow Articles by Snodderly, D. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nolan, J. M.
Right arrow Articles by Snodderly, D. M.

Spatial Profile of Macular Pigment and Its Relationship to Foveal Architecture

John M. Nolan,1 James M. Stringham,1,2,3 Stephen Beatty,4,5 and D. Max Snodderly1,6

1From the Department of Ophthalmology, Medical College of Georgia, Augusta, Georgia; 2UGA Vision Laboratory, Department of Psychology, University of Georgia, Athens, Georgia; and 4Macular Pigment Research Group, Department of Chemical and Life Sciences, Waterford Institute of Technology, Waterford, Ireland.

PURPOSE. Macular pigment (MP) is composed of two dietary carotenoids, lutein and zeaxanthin, and a carotenoid generated by the retina, meso-zeaxanthin. There is large intersubject variability in peak optical density, spatial profile, and lateral extent of macular pigment, and it has been suggested that foveal architecture may play a role in this variability. This study is an initial investigation of the relationship between the spatial profile of macular pigment and foveal architecture.

METHODS. Sixty normal subjects were enrolled (one was eventually excluded). The spatial profile of macular pigment optical density (MPOD) was measured by customized heterochromatic flicker photometry (cHFP). High-resolution macular thickness maps were obtained by optical coherence tomography. Four parameters were analyzed: (1) minimum foveal thickness (MFT) at the intersection of six radial scans; (2) central foveal thickness (CFT) averaged over the central 1 mm of the fovea; (3) foveal width identified as the region lacking a nerve fiber layer; and (4) foveal width measured from crest to crest. Lifestyle and vision information were obtained by questionnaire.

RESULTS. The mean ± SD MPOD at 0.25° eccentricity was 0.49 ± 0.23 and at 0.5° eccentricity, 0.41 ± 0.21. A first-order decreasing exponential function accounted for most of the variance of the MP profile averaged across subjects (r2 = 0.99). MPOD measured at 0.25° was unrelated to both measures of foveal thickness for the entire study group (r = 0.03, P = 0.81, and r = –0.08, P = 0.57, respectively). Similarly, MPOD measured at 0.5° was unrelated to foveal thickness in the entire study group (r = 0.12, P = 0.36 and r = –0.05, P = 0.71, respectively). However, when analyzed separately in the nonwhite subjects, the relationship between MPOD at 0.25° and MFT was positive and significant (r = 0.59, P = 0.01), but remained unrelated to CFT (r = 0.20, P = 0.41). Similarly, in the nonwhite subjects, the relationship between MPOD at 0.5° and MFT was positive and significant (r = 0.68, P < 0.01), but again was unrelated to CFT (r = 0.23, P = 0.32). There was no significant relationship between MPOD and either measure of foveal thickness in the white subjects. In the entire study group, there was a positive and significant relationship between foveal width and MPOD averaged across the fovea (r = 0.41, P < 0.01) and between foveal width and MP integrated across the fovea (r = 0.41, P < 0.01).

CONCLUSIONS. Foveal MP was positively and significantly related to foveal width in the entire study group. This relationship may be determined by the greater length of the cone axons (Henle fibers) in wider foveas. MPOD was unrelated to foveal thickness in the white subjects. However, in the nonwhite subjects there was a positive association between MFT and MPOD at the 0.25° and 0.5° eccentricities, suggesting that other personal characteristics modulate the MPOD–retinal thickness relationship.





This article has been cited by other articles:


Home page
IOVSHome page
M. L. Kirby, M. Galea, E. Loane, J. Stack, S. Beatty, and J. M. Nolan
Foveal Anatomic Associations with the Secondary Peak and the Slope of the Macular Pigment Spatial Profile
Invest. Ophthalmol. Vis. Sci., March 1, 2009; 50(3): 1383 - 1391.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the Association for Research in Vision and Ophthalmology