IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Originally published In Press as doi:10.1167/iovs.07-1103 on February 8, 2008
(Investigative Ophthalmology and Visual Science. 2008;49:2563-2567.)
© 2008 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.07-1103

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
iovs.07-1103v1
49/6/2563    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Beden, U.
Right arrow Articles by Erkan, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Beden, U.
Right arrow Articles by Erkan, D.

Orbital Drainage of Different Sizes of Colloids in Rabbits: A Dynamic Scintigraphic Study

Umit Beden,1 Oktay Yapici,2 Yuksel Sullu,1 Baris Sonmez,1 and Dilek Erkan1

1From the Departments of Ophthalmology and 2Nuclear Medicine, Ondokuz Mayis University, Kurupelit, Samsun, Turkey.

PURPOSE. To investigate the drainage patterns of radiolabeled colloids of different sizes injected into the orbital cavity in an animal model.

METHODS. Twenty-one orbits of 11 rabbits were included in the study. In group 1, human serum macroaggregates with particle sizes of 10 to 100 µm, labeled with 10 mL of 1480 MBq (40 mCi) technetium pertechnetate Tc 99m (99mTc), were used. In group 2, human serum albumin colloidal particles with particle sizes of 50 to 80 nm, labeled with 5 mL of 740 MBq (20 mCi) 99mTc, were used. In group 3, colloidal tin with particle sizes of 300 to 600 nm, labeled with 9 mL of 1665 MBq (45 mCi) 99mTc, were used. The dynamic acquisition of liver for 10 minutes (120 frames for 5 seconds) in a 128 x 128 matrix was acquired immediately after intraorbital injection and at the end of the second hour.

RESULTS. The liver in groups 2 and 3 and the lung in group 1 were visualized in 10 seconds or less in six, five, and four rabbits, respectively. The injected activity persisted in the orbits in varying percentages in all rabbits at the end of acquisition.

CONCLUSIONS. Intraorbital injections have a great potential for systemic absorption and should not be considered as local pharmaceutical administration.








HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the Association for Research in Vision and Ophthalmology