IOVS Hypertension
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Originally published In Press as doi:10.1167/iovs.07-1594 on March 3, 2008
(Investigative Ophthalmology and Visual Science. 2008;49:2673-2678.)
© 2008 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.07-1594

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
iovs.07-1594v1
49/6/2673    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wu, W.-C.
Right arrow Articles by Hsu, W.-C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wu, W.-C.
Right arrow Articles by Hsu, W.-C.

Efficacy and Safety of Biodegradable Collagen-Glycosaminoglycan Polymer as a Material for Scleral Buckling

Wei-Chi Wu,1,2 Chi-Chun Lai,1,2,3 Henry Shen-Lih Chen,1,2 Ming-Hui Sun,1 Lien-Min Lee,1 Chia-Pang Shih,4 Howard Wen-Hao Lee,5 and Wei-Cherng Hsu6,7

1From the Department of Ophthalmology, Chang Gung Memorial Hospital, Taoyuan, Taiwan; the 2College of Medicine, the 3Chang Gung Institute of Technology, and the 4Department of Business Administration, Chang Gung University, Taoyuan, Taiwan; the 5Department of Ophthalmology, Li Shin Hospital, Taoyuan, Taiwan; the 6Department of Ophthalmology, Buddhist Tzu Chi General Hospital, Taipei, Taiwan; and the 7Department of Ophthalmology, Tzu Chi University, Hualien, Taiwan.

PURPOSE. To test the efficacy and safety of a biodegradable collagen-glycosaminoglycan (CG) polymer as the material for scleral buckling in rabbit eyes.

METHODS. Segmental scleral buckling was performed by using a silicone sponge in one eye and a biodegradable CG polymer in the other eye of 20 rabbits. Wound and conjunctival reactions were evaluated by external photographs 1 day and then every week after surgery. Echography was used to evaluate the extent of the buckling effect. Electroretinograms were used to evaluate the retinal function after scleral buckling. Histology and immunohistochemistry were used to check the tissue reaction and distribution of myofibroblasts during wound healing. Scanning electronic microscopy of buckling materials was used to analyze structural changes after episcleral implantation.

RESULTS. Biodegradable collagen initially achieved a buckling effect comparable to a silicone sponge; the buckling effect decreased after 1 month. Within 8 to 12 weeks, the collagen was gradually absorbed. After implantation, the collagen matrix degraded, and the pore size decreased as a result of compression and degradation. In contrast, no major structural changes were observed in silicone sponges, except some cell debris, fibrin, and blood cells were detected inside the porous structure of the sponge. The inflammatory responses were comparable between sponge and collagen in most areas of peribuckling histology. In areas of degraded collagen, a foreign body reaction was observable. Electroretinography revealed no detectable difference in retinal function between control and experimental eyes.

CONCLUSIONS. Biodegradable collagen was used effectively and safely as a material for scleral buckling.








HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the Association for Research in Vision and Ophthalmology