IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Originally published In Press as doi:10.1167/iovs.07-1556 on March 3, 2008
(Investigative Ophthalmology and Visual Science. 2008;49:3262-3268.)
© 2008 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.07-1556

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
iovs.07-1556v1
49/8/3262    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Wells, A. P.
Right arrow Articles by Sachdev, N.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wells, A. P.
Right arrow Articles by Sachdev, N.

Corneal Hysteresis but Not Corneal Thickness Correlates with Optic Nerve Surface Compliance in Glaucoma Patients

Anthony P. Wells,1,2 David F. Garway-Heath,3 Ali Poostchi,1 Tracey Wong,2 Kenneth C. Y. Chan,2 and Nisha Sachdev2

1From Capital Eye Specialists, Wellington, New Zealand; 2Eye Department, Wellington Hospital, Wellington, New Zealand; and 3Moorfields Eye Hospital and UCL Institute of Ophthalmology NIHR Biomedical Research Centre, London, United Kingdom.

PURPOSE. To investigate relationships between acute intraocular pressure (IOP)–induced optic nerve head surface deformation and corneal hysteresis and thickness in glaucomatous and nonglaucomatous human eyes.

METHODS. This was a prospective experimental study of 100 subjects (38 with glaucoma, 62 without glaucoma). Data collected included spherical equivalent, optic disc diameter, central corneal thickness (CCT), axial length, cylinder, Goldmann IOP, Pascal IOP, and ocular pulse amplitude and ocular response analyzer (ORA) measurements of corneal hysteresis (CH). Elevation of IOP was induced in the right eye of each subject with a modified LASIK suction ring to an average of 64 mm Hg for less than 30 seconds. Heidelberg Retina Tomography II (HRT) was used to map the optic nerve surface before and during IOP elevation. Mean cup depth was calculated using built-in HRT data analysis software. Change in optic disc depth during IOP elevation was calculated for all right eyes, and tests for correlation with the parameters listed were performed.

RESULTS. Both CH and CCT were lower in the glaucoma group (8.8 mm Hg and 532 µm) than in the control group (9.6 mm Hg, P = 0.012; 551 µm, P = 0.011, respectively). There were no statistically significant differences in spherical equivalent, cylinder, axial length, optic disc size, or ocular pulse amplitude between the glaucoma and the control groups. There was no difference between the amount of IOP elevation between the two groups (P = 0.41), and the average difference in mean cup depth between baseline (mean cup depth, 247 µm) and during IOP elevation was 33 µm (29.8 µm in glaucoma and 36.1 µm in control; P = 0.5). Multiple variable analysis, controlling for age and sex, showed that CH was correlated with mean cup depth increase (P = 0.032). This relationship persisted (P = 0.032) after controlling for glaucoma status in addition to age and sex. Other factors, including CCT (P = 0.3), axial length (P = 0.9), ocular pulse amplitude (P = 0.22), and spherical equivalent (P = 0.38), were not significant in this model.

CONCLUSIONS. In the glaucoma patients but not the control patients, CH but not CCT or other anterior segment parameters was associated with increased deformation of the optic nerve surface during transient elevations of IOP. (ClinicalTrials.gov number, NCT00328835.)








HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the Association for Research in Vision and Ophthalmology