IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Originally published In Press as doi:10.1167/iovs.07-1596 on April 17, 2008
(Investigative Ophthalmology and Visual Science. 2008;49:3345-3350.)
© 2008 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.07-1596

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
iovs.07-1596v1
49/8/3345    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Haque, S.
Right arrow Articles by Jones, L.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Haque, S.
Right arrow Articles by Jones, L.

Epithelial Thickness Changes from the Induction of Myopia with CRTH RGP Contact Lenses

Sameena Haque, Desmond Fonn, Trefford Simpson, and Lyndon Jones

From the Centre for Contact Lens Research, School of Optometry, University of Waterloo, Ontario, Canada.

PURPOSE. To investigate changes in epithelial thickness after overnight wear of CRTH rigid gas–permeable (RGP) lenses (Paragon Vision Sciences, Mesa, AZ) for the correction of hyperopia.

METHODS. Twenty subjects wore a +3.50 D hyperopia-correcting CRTH lens on one eye for a single night in an attempt to induce myopia (first study). The untreated eye served as the control. Corneal and epithelial thickness was measured at nine points across the horizontal meridian by OCT. Measurements were obtained the night before lens wear, immediately after lens removal the next morning, and 1, 3, 6, and 12 hours after removal. Measurements were obtained 28 hours later, to observe recovery. Then, the attempted hyperopic corrections of +1.50 and +3.50 D were evaluated, using CRTH lenses in both eyes of 20 subjects for a single night (second study).

RESULTS. All values were compared to baseline unless otherwise stated. In the first study, the treated eye’s central and midperipheral epithelial thickness increased by 21.5% ± 8.6% and 13.3% ± 7.6%, respectively, after lens removal (P < 0.001). The control eye’s central epithelial thickness (CET) increased by 7.1% ± 6.0% (P < 0.05). In the second study, CET increased by 17.6% ± 8.5% (P < 0.001) in the +3.50 D–treated eye and by 13.3% ± 4.8% (P < 0.001) in the +1.50 D–treated eye. Midperipheral epithelial thickening was 5.9% ± 4.7% (P < 0.05) in the +3.50 D–treated eye and 6.0% ± 6.3% (P < 0.05) in the +1.50 D–treated eye.

CONCLUSIONS. CRTH lenses, designed to correct hyperopia, when worn overnight, caused an increase in CET. The amount of epithelial change seemed to differ with modified lens design.








HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the Association for Research in Vision and Ophthalmology