IOVS AJP: Heart and Circulatory Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Originally published In Press as doi:10.1167/iovs.08-2302 on August 8, 2008
(Investigative Ophthalmology and Visual Science. 2009;50:214-223.)
© 2009 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.08-2302

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
iovs.08-2302v1
50/1/214    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Strouthidis, N. G.
Right arrow Articles by Burgoyne, C. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Strouthidis, N. G.
Right arrow Articles by Burgoyne, C. F.

Detection of Optic Nerve Head Neural Canal Opening within Histomorphometric and Spectral Domain Optical Coherence Tomography Data Sets

Nicholas G. Strouthidis,1 Hongli Yang,1,2 Brad Fortune,3 J. Crawford Downs,4 and Claude F. Burgoyne1

1From the Optic Nerve Head Research Laboratory, 3Electrodiagnostic Services, and the 4Ocular Biomechanics Laboratory, Devers Eye Institute, Legacy Health System, Portland, Oregon; and the 2Biomedical Engineering Department, Tulane University, New Orleans, Louisiana.

PURPOSE. To assess the ability to detect the neural canal opening (NCO) and its characteristics within three-dimensional (3-D) histomorphometric and 3-D spectral domain optical coherence tomography (SD-OCT) reconstructions of the optic nerve head from nonhuman primate (NHP) eyes.

METHODS. NCO was delineated within 40 radial, sagittal sections of 3-D histomorphometric reconstructions of 44 normal eyes of 38 NHPs, each perfusion fixed at IOP 10 mm Hg, and 3-D SD-OCT (Spectralis; Heidelberg Engineering, Heidelberg, Germany) volumes acquired in vivo from a separate group of 33 normal eyes of 24 NHPs. Within all reconstructions, a least-squares ellipse was fitted to the 80 NCO points. For each eye, the dimensions and plane error (a gauge of planarity) of the fitted ellipse were calculated.

RESULTS. The NCO was successfully delineated within every section of each histomorphometric and SD-OCT reconstruction. Median plane error was similar within histomorphometric and SD-OCT volumes (8 µm, range 4–19, histomorphometry, and 10 µm, range 4–26, SD-OCT) and was small relative to the size of the ellipse. Median histomorphometric ellipse dimensions were 1453 µm (major axis, range 1218–1737) and 1066 µm (minor axis, range 808–1263). Median SD-OCT ellipse dimensions were 1512 µm (major axis, range 1191–1865) and 1060 µm (minor axis, range 772–1248).

CONCLUSIONS. The NCO is biologically continuous and relatively planar within all 3-D histomorphometric and SD-OCT reconstructions. These characteristics support its further evaluation as a reference plane for cross-sectional and longitudinal measurement of optic nerve head structures using 3-D SD-OCT.





This article has been cited by other articles:


Home page
IOVSHome page
N. G. Strouthidis, H. Yang, J. C. Downs, and C. F. Burgoyne
Comparison of Clinical and Three-Dimensional Histomorphometric Optic Disc Margin Anatomy
Invest. Ophthalmol. Vis. Sci., May 1, 2009; 50(5): 2165 - 2174.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by the Association for Research in Vision and Ophthalmology