IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Originally published In Press as doi:10.1167/iovs.08-1881 on June 19, 2008
(Investigative Ophthalmology and Visual Science. 2009;50:560-566.)
© 2009 by The Association for Research in Vision and Ophthalmology, Inc.
doi:10.1167/iovs.08-1881

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Supplementary Table
Right arrow All Versions of this Article:
iovs.08-1881v1
50/2/560    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Glassman, A. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Glassman, A. R.

Comparison of Optical Coherence Tomography in Diabetic Macular Edema, with and without Reading Center Manual Grading from a Clinical Trials Perspective

Adam R. Glassman,1 Roy W. Beck,1 David J. Browning,2 Ronald P. Danis,3 Craig Kollman1 for the Diabetic Retinopathy Clinical Research Network Study Group4

1From the Jaeb Center for Health Research, Tampa, Florida; 2Charlotte Eye Ear Nose and Throat Associates, PA, Charlotte, North Carolina; and the 3Department of Ophthalmology and Visual Sciences, University of Wisconsin, Madison, Wisconsin.

PURPOSE. To analyze the value of reading center error correction in automated optical coherence tomography (OCT; Stratus; Carl Zeiss Meditec, Inc., Dublin, CA) retinal thickness measurements in eyes with diabetic macular edema (DME).

METHODS. OCT scans (n = 6522) obtained in seven Diabetic Retinopathy Clinical Research Network (DRCR.net) studies were analyzed. The reading center evaluated whether the automated center point measurement appeared correct, and when it did not, measured it manually with calipers. Center point standard deviation (SD) as a percentage of thickness, center point thickness, signal strength, and analysis confidence were evaluated for their association with an automated measurement error (manual measurement needed and exceeded 12% of automated thickness). Curves were constructed for each factor by plotting the error rate against the proportion of scans sent to the reading center. The impact of measurement error on interpretation of clinical trial results and statistical power was also assessed.

RESULTS. SD was the best predictor of an automated measurement error. The other three variables did not augment the ability to predict an error using SD alone. Based on SD, an error rate of 5% or less could be achieved by sending only 33% of scans to the reading center (those with an SD ≥ 5%). Correcting automated errors had no appreciable effect on the interpretation of results from a completed randomized trial and had little impact on a trial’s statistical power.

CONCLUSIONS. In DME clinical trials, the error involved with using automated Stratus OCT center point measurements is sufficiently small that results are not likely to be affected if scans are not routinely sent to a reading center, provided adequate quality control measures are in place.





This article has been cited by other articles:


Home page
IOVSHome page
S. R. Sadda, P. A. Keane, Y. Ouyang, J. F. Updike, and A. C. Walsh
Impact of Scanning Density on Measurements from Spectral Domain Optical Coherence Tomography
Invest. Ophthalmol. Vis. Sci., February 1, 2010; 51(2): 1071 - 1078.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
A. Domalpally, B. A. Blodi, I. U. Scott, M. S. Ip, N. L. Oden, A. K. Lauer, P. C. VanVeldhuisen, and for the SCORE Study Investigator Group
The Standard Care vs Corticosteroid for Retinal Vein Occlusion (SCORE) Study System for Evaluation of Optical Coherence Tomograms: SCORE Study Report 4
Arch Ophthalmol, November 1, 2009; 127(11): 1461 - 1467.
[Abstract] [Full Text] [PDF]


Home page
Br J OphthalmolHome page
P A Keane, P S Mand, S Liakopoulos, A C Walsh, and S R Sadda
Accuracy of retinal thickness measurements obtained with Cirrus optical coherence tomography
Br J Ophthalmol, November 1, 2009; 93(11): 1461 - 1467.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
P. A. Keane, S. Liakopoulos, R. V. Jivrajka, K. T. Chang, T. Alasil, A. C. Walsh, and S. R. Sadda
Evaluation of Optical Coherence Tomography Retinal Thickness Parameters for Use in Clinical Trials for Neovascular Age-Related Macular Degeneration
Invest. Ophthalmol. Vis. Sci., July 1, 2009; 50(7): 3378 - 3385.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by the Association for Research in Vision and Ophthalmology