IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Originally published In Press as doi:10.1167/iovs.08-2459 on February 14, 2009
(Investigative Ophthalmology and Visual Science. 2009;50:2747-2756.)
© 2009 by The Association for Research in Vision and Ophthalmology, Inc.
doi:10.1167/iovs.08-2459

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
iovs.08-2459v1
50/6/2747    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by King-Smith, P. E.
Right arrow Articles by McFadden, G. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by King-Smith, P. E.
Right arrow Articles by McFadden, G. B.

The Contribution of Lipid Layer Movement to Tear Film Thinning and Breakup

P. Ewen King-Smith,1 Barbara A. Fink,1 Jason J. Nichols,1 Kelly K. Nichols,1 Richard J. Braun,2 and Geoffrey B. McFadden3

1From the College of Optometry, Ohio State University, Columbus, Ohio; the 2Department of Mathematical Sciences, University of Delaware, Newark, Delaware; and the 3National Institute of Standards and Technology, Gaithersburg, Maryland.

PURPOSE. To investigate whether the tear film thinning between blinks is caused by evaporation or by tangential flow of the tear film along the surface of the cornea. Tangential flow was studied by measuring the movement of the lipid layer.

METHODS. Four video recordings of the lipid layer of the tear film were made from 16 normal subjects, with the subjects keeping their eyes open for up to 30 seconds after a blink. To assess vertical and horizontal stretching of the lipid layer and underlying aqueous layer, lipid movement was analyzed at five positions, a middle position 1 mm below the corneal center, and four positions respectively 1 mm above, below, nasal, and temporal to this middle position. In addition, in 13 subjects, the thinning of the tear film after a blink was measured.

RESULTS. The total upward movement could be fitted by the sum of an exponential decay plus a slow steady drift; this drift was upward in 14 of 16 subjects (P = 0.002). Areas of thick lipid were seen to expand causing upward or downward drift or horizontal movement. The velocity of the initial rapid upward movement and the time constant of upward movement were found to correlate significantly with tear film thickness but not with tear-thinning rate.

CONCLUSIONS. Analysis indicated that the observed movement of the lipid layer was too slow to explain the observed thinning rate of the tear film. In the Appendix, it is shown that flow under a stationary lipid layer cannot explain the observed thinning rate. It is concluded that most of the observed tear thinning between blinks is due to evaporation.








HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by the Association for Research in Vision and Ophthalmology