IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Originally published In Press as doi:10.1167/iovs.08-2728 on March 5, 2009
(Investigative Ophthalmology and Visual Science. 2009;50:3378-3385.)
© 2009 by The Association for Research in Vision and Ophthalmology, Inc.
doi:10.1167/iovs.08-2728

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
iovs.08-2728v1
50/7/3378    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Keane, P. A.
Right arrow Articles by Sadda, S. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Keane, P. A.
Right arrow Articles by Sadda, S. R.

Evaluation of Optical Coherence Tomography Retinal Thickness Parameters for Use in Clinical Trials for Neovascular Age-Related Macular Degeneration

Pearse A. Keane,1 Sandra Liakopoulos,1,2 Renu V. Jivrajka,1 Karen T. Chang,1 Tarek Alasil,1 Alexander C. Walsh,1 and Srinivas R. Sadda1

1From the Doheny Image Reading Center, Doheny Eye Institute, Keck School of Medicine of the University of Southern California, Los Angeles, California; and the 2Department for Vitreoretinal Surgery, Center of Ophthalmology, University of Cologne, Germany.

PURPOSE. To investigate the relationship between automated and manually derived measurements of central retinal thickness from optical coherence tomography (OCT) and to determine the relationship between the foveal center point (FCP) and the foveal central subfield (FCS) in neovascular age-related macular degeneration (AMD).

METHODS. Data were collected from 216 patients with newly diagnosed neovascular AMD, who underwent StratusOCT imaging at diagnosis. Raw StratusOCT images for each patient were analyzed with the publicly available custom software OCTOR, which allows accurate manual grading of OCT B-scans. Manually derived central retinal thickness measurements were compared with measurements obtained from automated StratusOCT analysis. Manually obtained measurements of FCP and FCS were also compared.

RESULTS. The mean (±SD) difference in thickness between automated and manually derived FCP thickness was 7.9 µm (±90.8), but the maximum difference was 455 µm. The limits of agreement (95% confidence interval), between automated and manually obtained FCP thicknesses, were –173.7 µm (lower limit) and 189.6 µm (upper limit), with a coefficient of determination (R2) of 0.49 (P < 0.001). In contrast, the R2 for manually derived FCP and manually derived FCS thickness was 0.94 (P < 0.001), with a smaller mean (±SD) difference in thickness of 13.8 µm (±29.8).

CONCLUSIONS. Manual correction of errors in automated OCT segmentation may be necessary for accurate interpretation of anatomic outcomes for clinical trials of neovascular AMD. In addition, although measurement of FCS remains preferable for assessment of central retinal thickness, accurate measurement of FCP may represent an adequate alternative when FCS is unavailable.





This article has been cited by other articles:


Home page
IOVSHome page
S. R. Sadda, P. A. Keane, Y. Ouyang, J. F. Updike, and A. C. Walsh
Impact of Scanning Density on Measurements from Spectral Domain Optical Coherence Tomography
Invest. Ophthalmol. Vis. Sci., February 1, 2010; 51(2): 1071 - 1078.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by the Association for Research in Vision and Ophthalmology