IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


A more recent version of this article appeared on February 1, 2009
(Investigative Ophthalmology and Visual Science. )
© 2008 by The Association for Research in Vision and Ophthalmology, Inc.
doi:10.1167/iovs.08-2364

This Article
Right arrow Full Text (P<P[PDF])
Right arrow All Versions of this Article:
iovs.08-2364v1
50/2/787    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kok, P. H.B.
Right arrow Articles by Verbraak, F. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kok, P. H.B.
Right arrow Articles by Verbraak, F. D.

Article

A Model for the Effect of Disturbances in the Optical Media on the OCT Image Quality

Pauline H.B. Kok 1*, Hille W. Van Dijk 2, Thomas J.T.P. Van den Berg 3, and Frank D. Verbraak 4

1 Ophthalmology, Academic Medical Center, Meibergdreef 9, Amsterdam, 1105AZ, Netherlands
2 Ophthalmology, Academic Medical Center, Amsterdam, Netherlands
3 Ocular Signal Transduction, Netherlands Institute for Neuroscience, Royal academy of the Netherlands, Amsterdam, Netherlands
4 Ophthalmology, Academic Medical Center, Amsterdam, Netherlands; Biomedical Engineering and Physics, Academic Medical Center, Amsterdam, Netherlands

* To whom correspondence should be addressed. E-mail: p.h.kok{at}amc.nl.


   Abstract

PURPOSE. The loss of quality of Optical Coherence Tomography (OCT) images resulting from disturbances in the optical media has been modeled. METHODS. OCT measurements were performed in two healthy volunteers using the StratusOCT. Optical disturbances were approached in three ways simulated with filters. The studied effects were: light attenuation (absorptive and reflective filters), refractive aberrations (defocusing lenses) and light scattering/straylight (scattering filters). The same examiner scanned the subjects with the filters placed in front of the eye. The signal strength (SS) values of the scans were then collected. The strength of the filters were expressed in Optical Density, determined for the 830 nm central wavelength of the OCT, (OD{lambda}=830). RESULTS. A linear relationship has been found between the OD{lambda}=830, of the absorptive and reflective filters and the SS of the corresponding OCT images. Assuming that reduction of light from the OCT scanning spot on the retina is the critical factor, this light loss was determined for the scattering filters and the defocusing lenses. A comparable linear relationship was found between the SS value and the OD{lambda}= 830 of these filters. CONCLUSION. The presented model indicates that the loss of OCT image quality in patients with disturbances in the optical media is explained by attenuation of the light in the OCT scanning spot on the retina. A linear relationship between the SS and the single pass logarithmic attenuation of the OCT signal is shown, according to SS = constant -(9.9 (-9.4 to -10.6) ·OD{lambda}= 830).

Key Words: optical coherence tomography, cataract models, lens opacity




This article has been cited by other articles:


Home page
Br J OphthalmolHome page
G Vizzeri, R N Weinreb, A O Gonzalez-Garcia, C Bowd, F A Medeiros, P A Sample, and L M Zangwill
Agreement between spectral-domain and time-domain OCT for measuring RNFL thickness
Br J Ophthalmol, June 1, 2009; 93(6): 775 - 781.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Copyright © 2008 by the Association for Research in Vision and Ophthalmology