|
|
||||||||
From the Department of Ophthalmology, Nagoya University School of Medicine, Japan.
| Abstract |
|---|
|
|
|---|
METHODS. Conventional white-on-white (W-W) perimetry, blue-on-yellow (B-Y) perimetry, and the FarnsworthMunsell 100-hue test were performed in five patients with CSNB1. Diagnosis of CSNB1 was made by clinical and electrophysiological examinations. Twelve normal, age-matched control subjects and an additional 7 normal, highly myopic subjects were tested.
RESULTS. Color vision was normal in all the CSNB1 patients by the FarnsworthMunsell 100-hue test. B-Y perimetry demonstrated that blue cone sensitivity in CSNB1 was normal in the fixation area, but the mean sensitivities of the entire 60° field, the central 0°-to-15°, and 15°-to-30° ring were significantly decreased compared with the normal and myopic subjects. The sensitivity difference between 15°-to-30° and 0°-to-15° in B-Y perimetry increased significantly in CSNB1 compared with both normal and myopic control subjects.
CONCLUSIONS. Our perimetric results demonstrated that the S-cone function in CSNB1 is preserved only in the fovea and becomes abnormal toward the peripheral retina. This accounts for the normal color vision that tests mainly foveal function and the nonrecordable S-cone ERGs that arise mainly from peripheral retina.
| Introduction |
|---|
|
|
|---|
In CSNB1, the rod b-wave and scotopic threshold response (STR) are absent, whereas the rod a-wave is normal, indicating a dysfunction of the rod ON-bipolar cells.5 Cone-driven ERGs recorded with long-duration stimuli (long-flash photopic ERG) show an extremely reduced b-wave (ON) with a large d-wave (OFF).6 The shape of these ERGs then resemble the ERGs of monkeys after an intravitreal injection of 2-amino-4-phosphonobutyric acid, which blocks the ON synapses on the bipolar cells selectively.7 It has been shown that the principal component of the short-wavelengthsensitive cone (S-cone) ERG is cornea positive.8 9 10 It thus appears reasonable that S-cone ERG is nonrecordable in CSNB1 when stimulated by full-field stimuli.11 12 13 14 These results strongly suggest that there is a selective dysfunction of the ON (depolarizing) bipolar cells in both rod and cone visual pathways in patients with CSNB1.
In spite of the nonrecordable full-field S-cone ERG, it has been reported that the conventional psychophysical color vision tests are essentially normal in CSNB1.11 12 13 The reason for this discrepancy remains unresolved. We hypothesized that this discrepancy arises from the region of the retina tested. In conventional color vision testing, the central retina is examined, and in the full-field ERGs, the responses arise mainly from the peripheral retina. To test this hypothesis, we tested the color vision by the FarnsworthMunsell 100-hue test and performed blue-on-yellow (B-Y) perimetry in five patients with CSNB1.
| Materials and Methods |
|---|
|
|
|---|
Conventional full-field ERGs were recorded after pupil dilatation with 0.5% tropicamide and 0.5% phenylephrine hydrochloride, and 30 minutes of dark adaptation. The rod (scotopic) ERG was recorded with a blue stimulus at an intensity of 5.2 x 10-3 cd/m2. The rodcone mixed single flash (bright white) ERG was recorded with a white stimulus at an intensity of 44.2 cd/m2. The cone and the 30-Hz flicker ERG were recorded with a white stimulus intensity of 4 cd/m2 and 0.9 cd/m2, respectively.
The method for recording S-cone and long- and middle-wavelength-sensitive cone (L-M cone) ERGs has been described previously.15 16 An LED contact lens electrode was used. S-cone ERG was recorded with an LED of 450 nm (intensity, 3.3 log photopic trolands) under yellow background illumination (intensity, 4.8 log photopic trolands; Wratten No. 12, Eastman Kodak, Rochester, NY) from a slide projector. We have shown that the ERGs elicited under these conditions are S-cone mediated.15 The LM cone ERG was also recorded with an LED of 566 nm (stimulus intensity, 3.2 log photopic trolands) under blue background illumination (intensity, 4.1 log photopic trolands; Wratten No.43; Eastman Kodak). The stimulus frequency was 3 Hz with an ON-OFF ratio of 1.0.
The color vision test was performed using the FarnsworthMunsell 100-hue test in all patients with CSNB1.
The normal age-matched control group was composed of 12 subjects (mean age, 25.5 ± 5.1 years; range, 1429 years). The distance spherical refractive error in the tested eye ranged from -1.00 D to -4.00 D (-1.35 ± 2.03, mean ± SD), and the maximum power of the cylinder was -1.50 D. Visual acuity ranged from 20/20 to 20/10.
Because patients with CSNB1 are known to be highly myopic, additional control subjects consisted of seven highly myopic subjects (mean age, 25.6 ± 4.8 years; range, 1732 years). The distance spherical refractive error in the tested eyes ranged from -6.00 D to -11.00 D (-8.2 ± 1.75), and the maximum power of the cylinder was -3.00 D. Visual acuity ranged from 20/20 to 20/16.
All subjects met the inclusion criteria including normal intraocular pressure (<20 mm Hg) and no history of glaucoma or diabetes, congenital color vision defect, ocular surgery, or trauma. In addition, none of the subjects had a family history of glaucoma or diabetes mellitus. Slit lamp examination showed no opacity or yellowing of the crystalline lens.
W-W perimetry and B-Y perimetry were performed using program 30-2 of a Humphrey Field Analyzer (model 750; San Leandro, CA). The subjects pupils were fully dilated with 0.5% tropicamide. All testing was performed with an appropriate near-add. The 30-2 program measures the sensitivity at the fovea and at 76 equally spaced points, 6° apart, which covered the central 27°. We used 75 points for analysis without the two stimulus locations above and below the blind spot. W-W perimetry was performed with a 10-cd/m2 white background and a size III white stimulus, and B-Y perimetry was performed with a 100-cd/m2 yellow background and a size V blue (440 nm) stimulus.
The statistics were calculated on a personal computer (StatView 4.02; Abacus Concepts, Berkeley, CA). We divided the field into two concentric areas; a central 0°-to-15° and a 15°-to-30° band, and compared the mean thresholds of the fovea, the entire field, and the 0°-to-15° and 15°-to-30° bands for both W-W and B-Y perimetry in the three groups. A two-way analysis of variance was used to test the significance of the difference of the sensitivity between the three groups.
The research was conducted in accordance with institutional guidelines and with the tenets of the World Medical Association Declaration of Helsinki. After they received sufficient information, the subjects each provided written, informed consent to participation in the study.
| Results |
|---|
|
|
|---|
|
Color vision defects were not detectable in any patients with the FarnsworthMunsell 100-hue test. The total error scores of the seven normal myopes were 20 to 61 (mean score, 41) and those of the five eyes with CSNB1 ranged from 8 to 92 (mean score, 38). The upper limit of normal reported in the same age range was 100 errors.17
Figure 2 shows the gray scale of W-W and B-Y perimetry in five patients with CSNB1. B-Y perimetry in all cases demonstrated a decrease in sensitivity as the testing areas became more eccentric.
|
To examine the loss in B-Y sensitivity with eccentricity, we compared the ratio of the sensitivities in the 0°-to-15°and 15°-to-30° bands obtained by W-W and B-Y perimetry. The reduction of B-Y sensitivity in CSNB1 with eccentricity was more prominent compared with that in both the normal and the myopic subjects. Although the reduction of W-W sensitivity with eccentricity was also significantly different between CSNB1 and normal subjects, there was no significant difference between CSNB1 and the myopic subjects (Table 1) .
|
| Discussion |
|---|
|
|
|---|
There is some evidence that there is a predominance of S-cone ON units at the ganglion cell level, and the defect in CSNB1 may thus have a more profound effect on the S-cone system.18 Indeed, our patients with CSNB1 showed nondetectable S-cone ERG when stimulated with full-field stimuli, which agrees well with earlier reports.11 12 In spite of the nonrecordable S-cone ERG, the conventional color vision tests were essentially normal, which has been reported by other investigators.11 12 MacKay et al.11 believed that the S-cone ERGs depended on the presence of normal rod function and were therefore not essential for normal color vision. Kamiyama et al.12 reported the absence of S-cone ERGs with normal color vision evaluated by the Farnsworth Panel D-15 test in CSNB1. They compared the S-cone ERGs with a few conventional color vision tests but none of these studies examined the sensitivity of the short-wavesensitive cones in the peripheral retina.
In addition to conventional color vision tests, we assessed the short-wavelength pathway using B-Y automated perimetry. This technique uses a high-luminance yellow background to adapt selectively the green and the red pathways and suppresses rod activity simultaneously. This particular combination of wavelength and luminance of the stimulus and background isolates the short-wavelength system optimally.19 20 With the use of this technique, the S-cone sensitivities were topographically measured over 60° of the central field. The effect of lens absorption should be considered in the assessment of blue sensitivity; however, the foveal S-cone sensitivity showed no significant difference among three groups, which provided evidence against a lens-absorption effect.
We found that the S-cone sensitivity in CSNB1 was preserved normally only in the fovea but then decreased abnormally in the entire measured peripheral field. Because CSNB1 is usually associated with high myopia, as in our present patients, it was essential to take into consideration the S-cone sensitivity of highly myopic eyes, because blue sensitivity has been reported to decrease more significantly with an increase of refractive error.21 This significant depression of blue sensitivity in the peripheral retina in CSNB1 was also supported, even when compared with highly myopic subjects without CSNB1 as control subjects.
Considering the hill of vision, retinal sensitivity decreases with eccentricity from the fovea even in normal subjects according to the results of W-W perimetry (radial effect).22 We calculated the ratio of a central 0°-to-15° sensitivity to 15-to-30° sensitivity for both W-W and B-Y perimetry. The radial effect in B-Y sensitivity was greater in CSNB1 than in the normal and the highly myopic normal control subjects. In W-W perimetry, the radial effect in CSNB1 was more significant compared with normal subjects, but not when compared with the highly myopic normal subjects.
Milam et al.13 touched briefly on the results of B-Y perimetry in two patients with CSNB in their analysis of cutaneous melanomaassociated retinopathy (MAR). They reported that foveal blue sensitivity was reduced by 10 dB in MAR but was completely normal in CSNB. They did not perform conventional color vision tests in the CSNB patients, but it is very interesting that their patients with MAR showed the nonrecordable S-cone ERG with similar pattern of B-Y perimetry. Other studies have reported that there are several pathophysiological similarities between CSNB1 and MAR.23 24 In both disorders, the ON synapse to the bipolar cells in both the rod and cone visual pathways can be exclusively affected. The present results strongly suggest that the topographic abnormalities of the S-cone function in the retina have a similar pattern in both disorders.
Our results indicate that the S-cone function in CSNB1 was preserved only in the fovea and became abnormal toward the peripheral retina. This may explain the discrepancy between normal conventional color vision tests and nonrecordable S-cone ERGs in CSNB1, because the color vision tests are mainly related to the central retinal function, whereas the full-field ERG reflects the activity mainly in the peripheral retina.
| Footnotes |
|---|
Submitted for publication December 23, 1998; revised May 25, 1999; accepted June 24, 1999.
Commercial relationships policy: N.
Corresponding author: Hiroko Terasaki, MD, Department of Ophthalmology, Nagoya University School of Medicine, 65 Tsuruma-cho, Showa-ku, Nagoya 466-0065, Japan. E-mail: terasaki{at}med.nagoya-u.ac.jp
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
N. W. Khan, M. Kondo, K. T. Hiriyanna, J. A. Jamison, R. A. Bush, and P. A. Sieving Primate Retinal Signaling Pathways: Suppressing ON-Pathway Activity in Monkey With Glutamate Analogues Mimics Human CSNB1-NYX Genetic Night Blindness J Neurophysiol, January 1, 2005; 93(1): 481 - 492. [Abstract] [Full Text] [PDF] |
||||
![]() |
L E Allen, I Zito, K Bradshaw, R J Patel, A C Bird, F Fitzke, J R Yates, D Trump, A J Hardcastle, and A T Moore Genotype-phenotype correlation in British families with X linked congenital stationary night blindness Br J Ophthalmol, November 1, 2003; 87(11): 1413 - 1420. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Nakamura, S. Ito, H. Terasaki, and Y. Miyake Novel CACNA1F Mutations in Japanese Patients with Incomplete Congenital Stationary Night Blindness Invest. Ophthalmol. Vis. Sci., June 1, 2001; 42(7): 1610 - 1616. [Abstract] [Full Text] |
||||
![]() |
M Hayashi and S Yamamoto Changes of cone electroretinograms to colour flash stimuli after successful retinal detachment surgery Br J Ophthalmol, April 1, 2001; 85(4): 410 - 413. [Abstract] [Full Text] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |