|
|
||||||||
1From the Departments of Clinical Pharmacology and 2Ophthalmology, and the 3Institute of Medical Physics, University of Vienna, Austria.
| Abstract |
|---|
|
|
|---|
METHODS. In a randomized, double-masked, placebo-controlled, two-way crossover study in 12 healthy male volunteers the effects of a single dose of 100 mg sildenafil were studied. Subjects received sildenafil or placebo on two different study days. After administration, retinal hemodynamic parameters were measured every 20 minutes. Retinal vessel diameters and retinal blood velocity were assessed with the retinal vessel analyzer and bidirectional laser Doppler flowmetry, respectively. In addition, the response of retinal vessel diameters to stimulation with diffuse flicker light was studied. Blood pressure and intraocular pressure were measured with noninvasive techniques.
RESULTS. Sildenafil had no effect on mean arterial pressure, pulse rate, intraocular pressure, retinal blood velocity, or retinal arterial diameter. However, a significant increase in retinal venous diameters (4.7% ± 3.2%; P = 0.0028 versus placebo) and retinal blood flow 15.7% ± 18.0%; P = 0.029 versus placebo) was observed. Sildenafil had no effect on flicker-induced vasodilation in retinal arteries or veins.
CONCLUSIONS. The data indicate that sildenafil increases retinal venous diameters and retinal blood flow in healthy subjects. By contrast, it does not affect intraocular pressure and flicker-induced retinal vasodilation. Further studies are needed to elucidate whether this drug may be therapeutically used in retinal ischemic disease.
Although there is evidence that PDE-V inhibition has vasodilative effects in coronary arteries, no effect on IOP and optic nerve head blood flow has been observed in previous trials.3 4 Findings concerning the effects of sildenafil citrate on choroidal blood flow have been contradictory. Sildenafil has been shown to increase pulsatile choroidal blood flow,5 whereas foveolar choroidal blood flow, as assessed with laser Doppler flowmetry (LDF), was not affected.6 In the human retina, sildenafil has been shown to induce vasodilation in some7 but not in all8 studies. A study investigating the effect of sildenafil on retinal blood flow, however, had not been conducted.
In phototransduction, illumination activates the G-protein transducin that triggers activation of PDE-V and -VI. The rapid decline in cGMP levels, catalyzed by activation of PDE-V and -VI, closes cGMP-gated cationic channels in the membranes of photoreceptor cells. Photostimulation with diffuse luminance flicker has been shown to increase retinal vessel diameter.9 Hence, one may hypothesize that inhibition of PDE-V and -VI, both induced by sildenafil, may reduce flicker-induced vasodilatation by influencing signal transduction or by increasing cGMP levels in endothelial or smooth muscle cells.
We performed a study investigating the effect of sildenafil on retinal blood flow and flicker-induced retinal vasodilation in healthy subjects. Retinal vessel diameters and retinal blood velocities were measured with a retinal vessel analyzer (RVA; Carl Zeiss Meditec, Jena, Germany) and bidirectional laser Doppler velocimetry (LDV), respectively.
| Methods |
|---|
|
|
|---|
Study Design
Subjects were asked to refrain from alcohol and caffeine for at least 12 hours before trial days and were studied after an overnight fast. The study followed a randomized double masked, placebo-controlled two-way crossover design with sildenafil (100 mg oral sildenafil; Viagra, Pfizer) or matching placebo. To allow for double-masked conditions placebo tablets were identical in appearance, weight and taste with the sildenafil tablets. The washout period between the two study days was at least 4 days.
Description of Study Days
Dilation of the pupil was obtained with tropicamide (Mydriatikum Roche; Hoffmann-La Roche, Vienna, Austria). After a resting period of at least 20 minutes baseline measurements of ocular and systemic hemodynamics were performed. In addition, a 60-second flicker period with an 8-Hz flicker stimulus was scheduled and retinal vessel diameters were measured continuously. Thereafter, subjects received a single dose of 100 mg sildenafil or placebo. Ocular and systemic hemodynamic parameters were measured every 20 minutes over 3 hours and finally after 6 hours. Intraocular pressure (IOP) was measured in the fellow eye with applanation tonometry at baseline, every 60 minutes over 3 hours and after 6 hours. Sixty minutes after administration of sildenafil, vessel diameter were again assessed during flicker stimulation with 8 Hz over 60 seconds. Blood pressure was measured in 10-minute intervals during the entire study period. Pulse rate was monitored continuously. At each measurement cycle, the methods were applied in a predetermined order (RVA, blood pressure and pulse rate, LDV, IOP, if applicable). Measurements with the RVA and LDV were taken over 60 seconds each. Each method was performed by the same experienced observer throughout the study. The studies were performed at the Department of Clinical Pharmacology, Allgemeines Krankenhaus, Vienna.
Methods
Systemic Hemodynamics.
Systolic, diastolic, and mean arterial pressure (SBP, DBP, MAP, respectively) were measured on the upper arm by an automated oscillometric device. Pulse rate (PR) was automatically recorded from a finger pulse oximeter (HP-CMS patient monitor; Hewlett-Packard, Palo Alto, CA).
Applanation Tonometry and Ocular Perfusion Pressure.
The IOP was measured with a Perkins applanation tonometer (Clement Clarke, Edinburgh, UK). Oxybuprocaine hydrochloride with fluorescein was used to anesthetize the cornea.
Retinal Vessel Diameters.
The RVA (Carl Zeiss Meditec) is a commercially available system that comprises a fundus camera (model FF 450; Carl Zeiss Meditec), a video camera, a real-time monitor and a personal computer with analysis software for the accurate determination of retinal arterial and venous diameter.10 Retinal vessel diameters are analyzed in real time with a maximum frequency of 50 Hz. For this purpose, the fundus is imaged onto the charge-coupled device chip of the video camera, and data are stored on a video recorder. Evaluation of the retinal veins was performed on computer and that of arteries from the recorded videotapes.
Due to the absorbing properties of hemoglobin each blood vessel has a specific transmittance profile. Measurement of retinal vessel diameters is based on adaptive algorithms using these specific profiles. If the requirements for the assessment of retinal vessel diameters are not fulfilled anymore, as it occurs during blinks, the system automatically stops the measurement of vessel diameter. As soon as an adequate fundus image is achieved again, measurement of vessel diameters restarts automatically. In the present study, one major superior or inferior temporal retinal branch vein and one corresponding artery were measured. The automatic evaluation software was used to calculate the retinal vessel diameter. With this software, periods of inadequate measurements are automatically removed. The measurement location was within two disc diameters of the neuroretinal rim.
Retinal Blood Velocities and Retinal Blood Flow.
Retinal blood velocities were assessed with a bidirectional fundus camera-based laser Doppler velocimeter (model 4000; Oculix Sarl, Arbaz, Switzerland). The principle of blood flow velocity measurement by LDV is based on the optical Doppler effect. Laser light, which is scattered by moving particles (e.g., erythrocytes) is shifted in frequency. This frequency shift is proportional to the blood flow velocity in the retinal vessel. The maximum Doppler shift corresponds to the center line erythrocyte velocity. With bidirectional LDV the absolute velocity in the retinal vessels can be obtained.11 Measurements of retinal blood velocity were performed in retinal veins only at the same locations as were used for assessment of diameter with the RVA. During the measurements, care was taken that the DC value representing the total reemitted light from the fundus remained within ±15%. Evaluation of the LDV data was performed on computer (NeXT Computer, Redwood, CA), as described previously,12 using a time constant of 0.073. The full period of 60 seconds was taken for evaluation removing periods of eye blinks and saccades, as identified from unstable DC values. Retinal blood flow was calculated based on these measurements of maximum erythrocyte velocity (Velmax). Mean blood velocity (Vel) in retinal veins was calculated as (Velmax/1.6).13 In the present study, only one vein was studied, to allow for the time schedule described earlier. Blood flow through a specific retinal vein can then be obtained as
![]() |
Flicker Stimulation.
The flicker light was delivered through the illumination pathway of the fundus camera. The maximum luminance of the full-field flicker was approximately 2.5 x 10 to 5 µJ/(cm2 · flash). The flash duration was 30 µs. Diffuse luminance flicker was applied for 60 seconds at a frequency of 8 Hz during RVA measurements. Each flicker period was preceded by 60 seconds of baseline recording. To avoid having the flicker light itself interfere with the diameter measurement procedure, the light of the fundus camera and that of the flicker stimulation had to be separated. For this purpose, the following wavelength separation technique was adopted: One interference filter with a center wavelength of 590 nm and a bandwidth of 10 nm was introduced in the illumination pathway of the fundus camera. Hence, the eye was illuminated with light containing wavelengths between 580 and 600 nm. This window was chosen, because in this wavelength range the contrast between blood vessels and the surrounding tissue is optimal. A second matching interference filter was placed in front of the video camera. In addition, a 550-nm low-pass cutoff filter was placed in front of the flicker light source. With this technique the flicker stimulus is clearly perceived by the subject under study, but is not detected with the video camera. This ensures constant contrast in the fundus image throughout the flicker experiments.14
Data Analysis
All statistical analyses were performed on computer (Statistica, ver. 4.5; StatSoft Inc., Tulsa, OK). All outcome variables were calculated for each subject individually and then averaged. The effects of sildenafil on the outcome parameters was assessed with repeated measures ANOVA versus placebo. The interaction between time and treatment was taken as the level of significance to characterize treatment effects. The relative change in hemodynamic parameters induced by sildenafil was calculated. Data are presented as means ± SD. A two-tailed P < 0.05 was considered to indicate significance.
| Results |
|---|
|
|
|---|
|
|
|
|
|
|
| Discussion |
|---|
|
|
|---|
The present study indicates that sildenafil induces retinal vasodilation and increases retinal blood flow in vivo. After single dose administration of 100 mg sildenafil to healthy volunteers we observed a 4.7% increase in retinal venous diameters and a 15.7% increase in retinal blood flow. Results of studies investigating ocular hemodynamic effects of sildenafil are contradictory. In a randomized placebo-controlled crossover study in 15 healthy volunteers, no changes in retinal vessel diameters were observed 1 and 5 hours after administration of sildenafil.8 In this study, digitized monochromatic fundus images were used to measure retinal vessel size. The power in this study to detect a change in retinal vessel diameters of 6.5% was 80%. Considering that the changes in retinal vessel diameters observed in the present study were considerably smaller, these data are compatible. Our data are in keeping with the results from another study,7 in which an increase in retinal venous diameter was observed after 50 mg sildenafil (5.8%) in an open, uncontrolled study in which the same RVA was used as in the present trial. This study also reported a significant increase in retinal arterial diameter (5.8%) that was not observed in the present study. One possible explanation for this discrepancy is that younger subjects were used in the previous study (average age, 31 years). Our study is the first, however, to quantify changes in retinal blood flow after administration of sildenafil and thus the first to show that the increase in venous retinal diameters is accompanied by an increase in retinal perfusion. The lack of effect on red blood cell velocity, however, is compatible with a study using color Doppler imaging, in which no effect of sildenafil on blood velocities in the central retinal artery was observed.16 To speculate on the site of action of sildenafil in the present study is difficult, because we do not have data on the retinal microvasculature. However, our results are compatible with the idea that sildenafil induces vasodilation primarily on retinal microvessels with the observed venous dilation representing a passive secondary response. In this case, retinal venous velocity may well be unchanged, whereas retinal arterial velocity should be increased although not measured in the present study because of lower reproducibility.
Two different studies focused on the effect of sildenafil on choroidal blood flow, but the results were dependent on the methodology used. With LDF, no change in choroidal blood flow was observed in a randomized placebo-controlled study in 15 healthy subjects. This study had the power to detect a change of 20% in choroidal blood flow.6 By contrast, a significant increase in pulsatile ocular blood flow was reported after 50 mg of sildenafil using pneumotonometry.5 17 The reason for the discrepancy between these two studies has yet to be elucidated. One study focused on the effect of sildenafil on optic nerve head blood flow using LDF, again providing a negative result.6
The mechanism underlying the vasodilator effects of sildenafil in the present study remains to be established. In other vascular beds the drug induces vasodilation by enhancing the smooth muscle relaxant effects of nitric oxide (NO).18 19 One may hypothesize that this is also the case in the retina, where nitrates increase retinal vessel diameters after acute and chronic administration.20 21 This is in keeping with the idea that NO plays a key role in ocular blood flow regulation,22 as shown in numerous animal and human experiments. The NO dependence of sildenafilinduced vasodilation in the human retina, however, has not been shown.
In the present study, sildenafil did not alter the response of retinal arteries or veins to diffuse luminance flicker. In the retina, as in the brain, there is a tight coupling between metabolism and activity.9 13 23 24 The increase in optic nerve head blood flow appears to be directly related to activity changes in neural retinal tissue.25 The mechanism underlying the increase in retinal blood flow and retinal vessel diameters during flicker stimulation is hitherto unknown. There is some evidence, however, that NO plays an important role in retinal neurovascular coupling.24 26 Hence, it is somewhat unexpected that sildenafil, which is assumed to act through the L-arginine/NO pathway, does not affect flicker-induced vasodilation. Preserved neurovascular coupling during sildenafil administration, however, may in part explain the mild ocular side-effect profile of the drug.
Changes in blood pressure, pulse rate, and IOP in the present study were small, in keeping with results in several published trials.3 4 27 28 Hence, our results indicate that ocular perfusion pressure remained constant throughout the study period and that the increase in retinal blood flow resulted from direct vasodilation, rather than from changes in systemic hemodynamic parameters.
In conclusion, in our study, sildenafil increased retinal venous diameters and retinal blood flow in healthy subjects. By contrast, it did not affect IOP and flicker-induced retinal vasodilation. Further studies are needed to elucidate whether this drug may be used therapeutically in retinal ischemic disease.
| Footnotes |
|---|
Submitted for publication February 20, 2003; revised June 9, 2003; accepted June 12, 2003.
Disclosure: K. Polak, Pfizer (F); B. Wimpissinger, Pfizer (F); F. Berisha, Pfizer (F); M. Georgopoulos, Pfizer (F); L. Schmetterer, Pfizer (F)
The publication costs of this article were defrayed in part by page charge payment. This article must therefore be marked "advertisement" in accordance with 18 U.S.C.
1734 solely to indicate this fact.
Corresponding author: Leopold Schmetterer, Department of Clinical Pharmacology, Währinger Gürtel 18-20, A-1090 Vienna, Austria; leopoldschmetterer{at}univie.ac.at.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
K. E. Kotliar, B. Mucke, W. Vilser, R. Schilling, and I. M. Lanzl Effect of Aging on Retinal Artery Blood Column Diameter Measured along the Vessel Axis Invest. Ophthalmol. Vis. Sci., May 1, 2008; 49(5): 2094 - 2102. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Harris, L Kagemann, R Ehrlich, Y Ehrlich, C R Lopez, and V A Purvin The effect of sildenafil on ocular blood flow Br. J. Ophthalmol., April 1, 2008; 92(4): 469 - 473. [Abstract] [Full Text] [PDF] |
||||
![]() |
Z. Yuan, T. W. Hein, R. H. Rosa Jr, and L. Kuo Sildenafil (Viagra) Evokes Retinal Arteriolar Dilation: Dual Pathways via NOS Activation and Phosphodiesterase Inhibition Invest. Ophthalmol. Vis. Sci., February 1, 2008; 49(2): 720 - 725. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. H. Abramson, I. S. Rollins, A. Lin, P. Odell, and R. Folberg Tadalafil-Induced Subretinal and Choroidal Hemorrhage in a Patient With an Unsuspected Uveal (Choroidal and Ciliary Body) Melanoma Arch Ophthalmol, July 1, 2006; 124(7): 1058 - 1060. [Full Text] [PDF] |
||||
![]() |
T. M. Lincoln Cyclic GMP and Phosphodiesterase 5 Inhibitor Therapies: What's on the Horizon? Mol. Pharmacol., July 1, 2004; 66(1): 11 - 13. [Full Text] [PDF] |
||||
![]() |
E. Nagel, W. Vilser, and I. Lanzl Age, Blood Pressure, and Vessel Diameter as Factors Influencing the Arterial Retinal Flicker Response Invest. Ophthalmol. Vis. Sci., May 1, 2004; 45(5): 1486 - 1492. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |