IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2003;44:533-539.)
© 2003 by The Association for Research in Vision and Ophthalmology, Inc.
doi:10.1167/iovs.02-0170

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Goto, E.
Right arrow Articles by Tsubota, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Goto, E.
Right arrow Articles by Tsubota, K.

Tear Evaporation Dynamics in Normal Subjects and Subjects with Obstructive Meibomian Gland Dysfunction

Eiki Goto,1,2 Koji Endo,3 Atsushi Suzuki,4 Yoshiaki Fujikura,3 Yukihiro Matsumoto,1,2 and Kazuo Tsubota1,2

1From the Department of Ophthalmology, Tokyo Dental College, Chiba, Japan; the 2Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan; the 3Analytical Research Center, and the 4Health Care Products Research Laboratories No. 2, KAO Corporation, Tokyo, Japan.


    Abstract
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
PURPOSE. To test a newly developed tear evaporimetry system that detects real-time changes in tear evaporation rates and shows the tear film stability in patients with obstructive meibomian gland dysfunction (MGD).

METHODS. A ventilated chamber system with high-sensitivity microbalance sensor was used to evaluate tear evaporation. Tear evaporation rates and dynamic changes in them in response to blinking ("flip heights") were measured. Both were compared in 38 eyes of 22 normal subjects and 32 eyes of 21 patients with obstructive MGD, in a prospective case–control study. The relationship between tear evaporation rates and flip heights to meibomian gland orifice obstruction was also analyzed.

RESULTS. Changes in tear evaporation rates produced by blinking were detected. The tear evaporation rates in the patients’ group were 5.8 ± 2.7(10-7) g/cm2 per second, significantly higher than in normal subjects (4.1 ± 1.4[10-7] g/cm2 per second; P = 0.0008). The flip heights in the obstructive MGD group were 0.58 ± 0.33(10-7) g/cm2 per second, significantly higher than in normal subjects (0.39 ± 0.27[10-7] g/cm2 per second, P = 0.02). The correlations between both tear evaporation rates and flip heights to the meibomian gland orifice obstruction score were statistically significant (P < 0.0001 and P = 0.004, respectively).

CONCLUSIONS. This new system was helpful in differentiating MGD patients from normal subjects. These significantly higher evaporation rates and higher flip heights reflect the unstable tear evaporation and may well indicate unstable tear film in patients with obstructive MGD with abnormal evaporative tear loss.


Tear evaporation has been studied as a major factor in tear dynamics.1 2 3 4 5 6 Tear evaporation measurements, in examinations for dry eye, are recognized as an important technique for differentiating dry eye syndrome subcategories—that is, aqueous tear deficiency (ATD) dry eye and lipid tear deficiency (LTD) dry eye (also known as evaporative dry eye)1 2 3 4 5 6 and for evaluating treatment efficacy.3

The lacrimal glands secrete aqueous tears. They are distributed over the ocular surface by blinking, drain into the lacrimal punctum, and evaporate into the air.7 Aqueous tears are covered by tear lipid secreted by the meibomian glands that spreads to form an oily layer of preocular tear film. Meibomian gland secretion limits evaporative tear loss, provides a barrier function at the lid margin, supplies lubrication during blinking, and maintains an optically smooth surface.7 8 9 10 11 12 13

Tear dynamics have been studied by Schirmer test,14 by the cotton thread test,15 16 with meniscometers,17 with tear evaporimeters,3 4 5 6 by measuring turnover rates by tear clearance and the tear-function index,18 19 20 and by tear interference.21 22 23 24 25 Also, tear stability has been studied with fluorescein tear break-up time (BUT).15 26 27 BUT has been considered a practical method to indicate tear stability. However, the instillation of fluorescein dye is not a fully noninvasive procedure.

In the evaluation of dry eye syndrome with abnormal tear dynamics, despite clear criteria for ATD,14 15 the diagnosis of evaporative dry eye, mainly represented by obstructive meibomian gland dysfunction (MGD)—that is, undetectable by tear measurement of secretion by Schirmer’s test—is made indirectly by examining morphologic changes in the meibomian glands,28 by meibography,29 by semiquantification of ease of meibum (mebomiam gland secretion) expression with digital compression,1 2 by quantification of lid margin meibum by meibometry,22 30 by semiquantification of the presence of tear lipid by tear interference,22 23 31 and by a combination of dye staining and impression cytology,32 or it is inferred by demonstrating rapid tear evaporation.1 2 33

Obstructive MGD is the major cause of lipid tear deficiency and evaporative dry eye and has recently attracted attention as a cause of ocular discomfort.2 15 32 34 Obstructive MGD decreases the lipid supply, which in turn leads to decreased tear stability, loss of lubrication, and damage to the ocular surface epithelium, thus producing symptoms.2 15 32

Tear evaporation measurements are noninvasive, and they are essential for identifying tear dynamics, differentiating between dry eye subcategories including evaporative dry eye, and evaluating results of treatment.1 2 3 4 5 6 15 Human tear evaporation rates have been reported, and differences between the results in normal subjects and patients with dry eye vary with the methods used.3 4 6 Also, humidity-sensing systems in previous reports have a slower response that may not measure quick changes in tear evaporation, and they do not incorporate recent advances in computer technology.

We thought that if we could develop a system to measure tear evaporation with a more rapidly responding humidity sensor and sophisticated software, we would be able to investigate real-time dynamic changes in tear evaporation, which would be more helpful in differentiating dry eye subcategories.15 35 In this article we report the development of a new system to measure tear evaporation rates and dynamic changes by blinking, which represents the stability of the tear film, by using a microbalance, high-sampling–rate humidity sensor, and sophisticated software for real-time measurement and analysis.


    Methods
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Tear Evaporimeter Setup
Tear evaporation from the ocular surface was evaluated by making the following measurements.35 Briefly, the evaporimeter consisted of an eyecup in the form of a ventilated chamber4 5 having a volume of 20 cm3 and tightly covering the eye; air, with known water content and infused into the cup as a tear evaporation carrier by an air compressor at a constant flow rate (150 mL/min), and a quartz crystal sensor (9 MHz A-T cut quartz crystal with 8 mm in diameter and 0.2 mm in thickness), known as the "microbalance," which has high sensitivity to humidity.35 The frequency of the sensor shifts in response to changes in humidity. Evaporation rates were measured by calculating the difference between the water content of the air entering and exiting the cup.35 The instrumental setup and schema are shown in Figures 1A 1B and 1C . Evaporation rates, J (in grams per square centimeter per second), were calculated as follows

(1)
Where {Delta}F, is the frequency shift (in Hertz) between the measured value and the baseline value on the frequency counter, k (in Hertz) is the known frequency shift for a relative humidity change, {rho} (in grams per cubic centimeter) is the water content of air having 100% RH at a given temperature, V (in cubic centimeters per second) is the flow rate of the carrier gas, and A (in square centimeters) is the area measured (Fig. 2) .35 In this study, A and V were 13 cm2 and 2.5 cm3/sec, respectively. Room temperature was fixed at 22°C. Thus, {rho}, V, k, and A are all constants in this setup, and evaporation rates are proportional to {Delta}F, the frequency shift (Fig. 2) .



View larger version (83K):
[in this window]
[in a new window]
 
FIGURE 1. (A) Counterclockwise from the top left: computer with evaporation measurement software, probe, drying unit, gas-flow meter, frequency counter, power supply, and air compressor. (B) Schematic diagram of the air resource, frequency counter, power supply, and personal computer are also shown. Air is dried during passage through a drying unit (20 x 200 mm) containing silica gel. (C) The subject holds the probe as gently as possible without allowing air to leak from the chamber.

 


View larger version (33K):
[in this window]
[in a new window]
 
FIGURE 2. Tear evaporation rates from the ocular surface were calculated by subtracting evaporation rates of the open eye and closed eye: {Delta}J = J (open eye) - J (closed eye). Flip heights are the average height of each flip on the frequency profile. In blinking, when the eye was shut, the flip was descending, and when the eye started to open, the flip was ascending.

 
We measured evaporation rates with the eye closed, with the eye open (natural blinking), and with forced blinking every 5 seconds, twice the normal rate.3 36 To avoid the contribution of evaporation from lid skin, we calculated the differences between open and closed eyes.3 This allowed us to avoid the application of an oily cream around the eyes.5 The tear evaporation rates from the ocular surface ({Delta}J) were defined as the difference between two steady state evaporation rates (5 seconds, average of 20 data points): that with open eye (natural blinking) and with closed eye (transpiration from skin surface). Thus, the evaporation rates from the ocular surface are proportional to the difference in frequency shift (Fig. 2)

(2)
Flip heights (in grams per square centimeter per second), which appeared on the frequency profile of the forced blinking at the steady state, were estimated from the average height of each flip (flip heights in Fig. 2 ). Thus, flip heights can represent small changes in tear evaporation due to blinking. Software developed using commercial software (Visual Basic; Microsoft, Redmond, WA) was programmed for evaporation measurements, records, and analysis (programmed in Windows 98; Microsoft). The data sampling rate was four times a second. Real-time changes in the frequency data appeared on the display of a personal computer in synchrony with this sampling rate, and that allowed us to analyze tear evaporation dynamically.

Examinations of Tears, the Ocular Surface, and Meibomian Glands
The ocular surface was examined by the double-staining method. Preservative-free solution (2 µL) consisting of 1% fluorescein and 1% rose bengal dye was applied to the conjunctival sac.37 The intensity of rose bengal staining of the cornea and conjunctiva was recorded, with a maximum score of 9.14 Fluorescein staining of the cornea was also rated from 0 to 9.38 BUT was then measured three times, and the measurements were averaged.37 The Schirmer test was performed to measure tear secretion.14 18 38 The inclusion criteria for the diagnosis of obstructive MGD were the presence of meibomian gland dropout, poor meibum expression, and lack of active inflammation.1 2 32 A transillumination examination (meibography) was performed with a fiber-optic device (L-3920; Inami, Co., Tokyo, Japan).29 Loss of the visible structure of the meibomian glands (gland dropout) revealed by meibography was considered evidence of obstructive MGD, because this finding has been reported to be a good parameter for obstructive MGD-associated ocular surface changes.1 2 29 The degree of meibomian gland dropout was scored as described previously: grade 0, no gland dropout; grade 1, gland dropout in less than half of the inferior tarsus; and grade 2, gland dropout in more than half of the inferior tarsus.1 2 To assess expression of meibum and obstruction of the meibomian gland orifice, digital pressure was applied on the upper tarsus, and the degree of ease of expression of meibomian secretion (meibum) was evaluated semiquantitatively as follows: grade 0, clear meibum easily expressed; grade 1, cloudy meibum expressed with mild pressure; grade 2, cloudy meibum expressed with more than moderate pressure; and grade 3, meibum cannot be expressed even with intense pressure.1 2

Subjects
We tested 38 eyes of 22 consecutive normal subjects (10 men and 12 women; average age, 39.5 ± 9.5 years) and 32 eyes of 21 patients with obstructive MGD (9 men and 12 women; average age, 46.0 ± 14.4 years). Both eyes or only the right eye were measured.

The normal subjects had clear corneas and conjunctivas (as assessed by slit-lamp biomicroscopy with fluorescein staining), no clinical manifestations, a normal Schirmer test result (23.3 ± 10.3 mm), and a normal meibomian gland orifice obstruction score (0.4 ± 0.5). The patients with obstructive MGD had normal Schirmer test results (21.7 ± 10.5 mm), with vital staining of the corneas or conjunctivas with fluorescein (0.06 ± 0.4) and rose bengal (0.3 ± 0.8), and a short BUT (4.6 ± 3.1 second). The meibography score was 1.2 ± 0.4, and the meibomian orifice obstruction score was 2.2 ± 0.4 in the obstructive MGD group. None of the subjects had any evidence of ocular infection, were contact lens wearers, had had punctal occlusion performed, had blepharospasm or abnormal blinking. Complicated dry eye cases, such as Sjögren syndrome, Stevens-Johnson syndrome, and ocular pemphigoid were also excluded from the study. The research followed the tenets of the Declaration of Helsinki, and informed consent was obtained from all the subjects after explanation of the nature and possible consequences of the study.

Main Outcome Measurement
Tear evaporation rates and flip heights were compared between the two groups. In all subjects, the relationships between meibomian gland orifice obstruction score and both tear evaporation rates and flip heights were analyzed to investigate how the amount of lipid on the lid margin and ocular surface affects the evaporation rates and its dynamic changes.

Tear Evaporation Rates Corrected with Ocular Surface Area
In this report, we adopted the area of the eyecup for the evaporation rate calculation as a fixed value of 13 cm2, for real-time evaporation measurement (equation 1) . Rolando and Refojo reported the tear evaporation rates divided by the exposed ocular surface area photographically.5 We also measured the exposed ocular surface area (A') and palpebral aperture photographically with a charge-coupled device (CCD) camera (PCAM-VUA; NEC Corp., Tokyo, Japan) with image-analysis software (Scion Image, Scion Corp., Frederick, MD) in all 38 eyes of the normal subjects. The area and size of the aperture were measured as follows: an eye of each subject and a scale were taken in the same image. The area of exposed eye surface and the length of its palpebral aperture were measured on the image in the unit of pixel by image analysis. These values were converted to the unit of an actual dimension using the scale. The relationship (linear regression) between the exposed area and the size of the aperture was obtained (Fig. 3) .



View larger version (25K):
[in this window]
[in a new window]
 
FIGURE 3. The exposed ocular surface area and the size of the palpebral aperture were obtained photographically in all 38 eyes of normal Asian subjects.5 Solid and dashed lines: results of linear regression and the 95% confidence interval: y = 0.22x - 0.55, r = 0.901, P < 0.0001. Our results, obtained in Asian eyes were similar with the corresponding values reported by Rolando and Refojo (Western and Asian eyes, y = 0.28x - 0.44, r = 0.991).5

 
As the tear evaporation rates from the ocular surface ({Delta}J) were obtained by subtraction between two steady state evaporation rates, that is, open eye and closed eye3 (equation 2 , which is a different method from Roland and Refojo5 using cream to suppress the evaporation from the skin surface), ocular evaporation rates ({Delta}J') by the exposed ocular surface area (A') was calculated and corrected as follows:

(3)
For all obstructive MGD subjects, we adopted the averaged exposed ocular surface area of all normal subjects for correction, because we had not measured the exposed ocular surface area and the palpebral aperture size.

Statistical Analysis
All data are shown as the mean ± SD. The Mann-Whitney test was applied to tear evaporation rates and comparison of flip heights. Linear regression analysis was applied to relationships with meibomian gland orifice obstruction score. It was also applied to the relationship between exposed ocular surface area and palpebral aperture. P < 0.05 was accepted as statistically significant. Analyses were performed on computer (Instat 3.0 for Mac OS X; Graphpad Software, Inc., San Diego, CA).


    Results
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Tear Evaporation Rates in Representative Cases
Figure 4 shows the profiles of frequency shifts and tear evaporation rates in a representative subject in the normal group (Fig. 4A) and the obstructive MGD group (Fig. 4B) . With the eye closed, the humidity sensor responded to transpiration from the skin and reached a steady state in approximately 10 seconds. With the eye opened (naturally blinking started), the sensor responded to tear evaporation from the ocular surface in addition to skin transpiration, and it reached a steady state after approximately 10 seconds. As shown in Figure 4 , during forced blinking (1 blink/5sec), regular flips of frequency appeared on the profile at a steady state at the same interval as the blinks, and the frequency shifts were higher in the obstructive MGD case.



View larger version (24K):
[in this window]
[in a new window]
 
FIGURE 4. The tear evaporation rates of the normal subject are 4.5 (10-7) g/cm2 per second, and the flip heights are 0.60 (10-7) g/cm2 per second (A). The tear evaporation rates of the patients with obstructive MGD are 7.4 (10-7) g/cm2 per second), and the flip heights are 1.2 (10-7) g/cm2 per second (B).

 
Tear Evaporation Rates and Flip Heights Analysis
Tear evaporation rates by subject group are shown in Figure 5A . The tear evaporation rates (free blinking) of normal subjects were 4.1 ± 1.4 (10-7) g/cm2 per second), and were significantly higher, 5.8 ± 2.7 (10-7) g/cm2 per second, in the obstructive MGD group (Table 1 , P = 0.0008). Tear flip heights by subject group are shown in Figure 5B . The flip heights (at forced blinking every 5 seconds) of the normal subjects were 0.39 ± 0.27 (10-7) g/cm2 per second, and were significantly higher, 0.58 ± 0.33 (10-7) g/cm2 per second, in the obstructive MGD group (Table 1 , P = 0.02). The flip height–evaporation rate ratio was 9.48% in normal subjects and 9.89% in the obstructive MGD group.



View larger version (22K):
[in this window]
[in a new window]
 
FIGURE 5. The tear evaporation rates (A, free blinking) and flip heights (B, forced blinking) in the MGD group were significantly higher than in the normal subjects.

 

View this table:
[in this window]
[in a new window]
 
TABLE 1. Comparison of Our Tear Evaporation Rates with the Values in Literature

 
Relationship between Tear Evaporation Rates and Meibomian Gland Orifice Obstruction Scores
Relationships to the meibomian gland orifice obstruction scores are shown in Figure 6A . A significant correlation was found between meibomian gland orifice obstruction scores and tear evaporation rates (r =.49, P < 0.0001) in all normal subjects and in patients with obstructive MGD.



View larger version (33K):
[in this window]
[in a new window]
 
FIGURE 6. Solid and dotted lines: results of linear regression and the 95% confidence interval, respectively, in (A) and (B). The derived regression function, correlation coefficient (r), and probability are shown.

 
Relationship between Flip Heights and Meibomian Gland Orifice Obstruction Scores
The relationships to meibomian gland orifice obstruction scores are shown in Figure 6B . A significant relationship between meibomian gland orifice obstruction scores and flip heights was found (r = 0.37, P = 0.004) in all normal subjects and in patients with obstructive MGD.

Relationship between the Exposed Ocular Surface Area and the Size of the Palpebral Aperture, Evaporation Rates, and Flip Heights, Corrected with the Exposed Ocular Surface Area
Figure 3 shows the relationship between the area of exposed ocular surface and its palpebral aperture (all Asian eyes). The line in Figure 3 represents the regression results; y = 0.22x - 0.55, r = 0.901, P < 0.0001. Our results, obtained in Asian eyes were similar to the corresponding values reported by Rolando and Refojo (Western and Asian eyes, y = 0.28x - 0.44, r = 0.991).5 When we use the exposed ocular surface area for calculation, the tear evaporation rates (free blinking) of normal subjects were 5.7 ± 1.4 (10-7) g/cm2 per second and were significantly higher, 7.4 ± 2.8 (10-7 x g/cm2 per second, in the obstructive MGD group (Table 1 , P = 0.001). The flip heights (at forced blinking every 5 seconds) of normal subjects were 3.5 ± 2.2 (10-7) g/cm2 per second and those of the obstructive MGD group were significantly higher, 5.7 ± 3.2 (10-7) g/cm2 per second (P = 0.001). The flip height–evaporation rate ratio was 61.55% in normal subjects and 77.18% in the obstructive MGD group, respectively.


    Discussion
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
This study reports a new tear evaporimetry system that uses microbalance technology, which accurately and sensitively detects changes in humidity at a high sampling rate (0.25 seconds) with sophisticated software, and its application to patients with obstructive MGD. This new method for the first time shows dynamic changes in tear evaporation in response to blinking as flip heights, which was analyzed to indicate the differences between normal subjects and patients with obstructive MGD. The results are shown on a computer display by real-time processing. The new method noninvasively generates additional information on the formation and dynamics of the aqueous tear and lipid tear layer. Both the real-time tear evaporation profiles (Figs. 2 4) and dynamic changes in response to blinking (flip heights) are advantages of this system over those described in previous reports (summarized in Table 1 ) to indicate the tear film stability.1 2 3 4 5 6 As shown in Figures 2 4A and 4B , during forced blinking, regular flips of frequency appeared on the profile at a steady state at the same intervals as the blinks. These results indicate that our evaporimeter can detect dynamic changes in blinking, especially in patients with obstructive MGD.

The tear evaporation profile showed that the new measurement system could detect rapid dynamic changes in tear evaporation rates in response to blinking after reaching a steady state. It took approximately 10 seconds to reach a steady state with minimal gas flow, after which flips appeared with blinking.

Significantly increased tear evaporation rates were reported in the obstructive MGD group (Fig. 5A) . Patients with MGD have been reported to have poor lipid levels and higher evaporation rates (Table 1) .1 2 22 23 33 Because we compared the two groups with normal Schirmer test results, these evaporation rates can be considered a direct representation of a function to limit evaporative tear loss in the ocular surface environment. Thus, our results indicated an insufficient amount and spread of tear lipid layer, which leads to abnormal evaporative tear loss and unstable tear film on the ocular surface of patients with obstructive MGD.

The flip heights in the obstructive MGD group were significantly higher than in the normal subjects (Fig. 5B) . The flip height analysis measures dynamic changes in preocular humidity as a result of blinking. If the subject has a normal lipid secretion and it spreads to cover the aqueous layer normally, evaporation rates measured in the eyecup remain stable during blinking. However, if the quality and/or quantity of tear lipid is inadequate, tear evaporation represented by flip heights are more unstable, decreasing with eye closure and spiking when the eye opens because the tear lipid layer is considered responsible for limiting evaporative tear loss and for stable preocular humidity.7 8 9 10 11 39 The flip height–evaporation rate ratio, which indicates the ratio of change of tear evaporation by blinking in total tear evaporation, was 9% to 10% in our system setting. The ratio after the correction using the photographically measured ocular surface area increased to 60% to 80%, which appeared to be affected more by the actual exposed ocular surface area. Recently, Shine and McCulley40 41 42 43 have reported the abnormality in the quality of meibomian lipid in patients with chronic blepharitis. Such a qualitative lipid change may occur in the patients with obstructive MGD as well, and the role of this change with polar and nonpolar lipid composition to abnormal evaporative tear loss could be investigated with the combination of lipid analysis40 41 42 44 45 and clinical tear lipid evaluation22 23 30 34 including tear evaporimetry.

According to the regression analyses (Fig. 6) , tear evaporation rates increased proportionally with the severity of meibomian gland obstruction. Under normal aqueous tear production with normal Schirmer test results, tear evaporation rates correlated with lipid tear status—that is, secretion, spread, and thickness of meibum.1 2 8 33 Flip heights and the severity of meibomian gland orifice obstruction were also found to correlate with lipid status. Thus, dynamic changes in tear evaporation appeared to reflect the severity of the obstruction. Tear evaporation rates and dynamic changes in them may well be affected by the amount of tear lipid on the lid margin and on the ocular surface.

Tear evaporation rates have been reported, by using several methods with different results and data (Table 1) .1 2 3 4 5 6 We concluded that these differences are derived from the different methodology and system setup. Using the closed-chamber system, we have reported tear evaporation rates at 40% ambient humidity.1 2 3 In this report, we used the ventilated-chamber system with 10% to 15% humidity inside the eyecup. Also, we fixed the area of evaporation measurement, compared to that in previous studies, that calculated the area from the palpebral fissure.3 4 5 Strictly speaking, a method should be developed that measures the evaporation from the ocular surface alone. In this study, we also measured the area of exposed ocular surface and the size of palpebral aperture and tried to correct the tear evaporation rate by ocular surface area, but only in normal subjects. The relationship correlated well to findings in the report by Roland and Refojo.5 At this moment, to compare the tear evaporation rates between subjects or at a different time point, it would be better to use the same system setup.

Our study also had some drawbacks. Accurate measurement of the dynamics of tear evaporation requires a quicker responding sensor, because lid blinking was more rapid than our sampling rate.36 However, if we had increased the sampling rate, reliability and accuracy would be lost.

For evaluation and quantification of aqueous and lipid tear production, this system is expected to be useful in combination with noninvasive (i.e., more reliable) methods, such as tear interference, and meibometery, and meniscometery to enhance the accuracy of dry eye diagnosis and classification.15 17 21 22

Our system noninvasively and easily measured ocular surface tear evaporation and its dynamics in response to blinking to show tear stability, and this facilitated differentiation of obstructive MGD from normal eyes, while indicating unstable tear film. This system is also expected to contribute to the evaluation of the treatment of obstructive MGD and evaporative dry eye.


    Footnotes
 
Presented in part at the Third Lacrimal Gland, Tear Film, and Dry Eye Syndrome Conference, Maui, Hawaii, November 2000.

Supported by the Japanese Ministry of Education, Medical School Faculty and Alumni Grants of Keio University Medical Science Fund, and the Hightech Research Center at Tokyo Dental College.

Submitted for publication February 19, 2002; revised August 16, 2002; accepted September 23, 2002.

Commercial relationships policy: E (KE, AS, YF); N (all others).

The publication costs of this article were defrayed in part by page charge payment. This article must therefore be marked "advertisement" in accordance with 18 U.S.C. §1734 solely to indicate this fact.

Corresponding author: Kazuo Tsubota, Department of Ophthalmology, Tokyo Dental College, 5-11-13 Sugano, Ichikawa-shi, Chiba 272-8513, Japan; eikigoto{at}nifty.com.


    References
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 

  1. Shimazaki, J, Goto, E, Ono, M, Shimmura, S, Tsubota, K. (1998) Meibomian gland dysfunction in patients with Sjogren syndrome Ophthalmology 105,1485-1488[CrossRef][Medline][Order article via Infotrieve]
  2. Shimazaki, J, Sakata, M, Tsubota, K. (1995) Ocular surface changes and discomfort in patients with meibomian gland dysfunction Arch Ophthalmol 113,1266-1270[Abstract/Free Full Text]
  3. Tsubota, K, Yamada, M. (1992) Tear evaporation from the ocular surface Invest Ophthalmol Vis Sci 33,2942-2950[Abstract/Free Full Text]
  4. Mathers, WD, Binarao, G, Petroll, M. (1993) Ocular water evaporation and the dry eye: a new measuring device Cornea 12,335-340[CrossRef][Medline][Order article via Infotrieve]
  5. Rolando, M, Refojo, MF. (1983) Tear evaporimeter for measuring water evaporation rate from the tear film under controlled conditions in humans Exp Eye Res 36,25-33[CrossRef][Medline][Order article via Infotrieve]
  6. Hamano, H, Hori, M, Mitsunaga, S. (1980) Application of an evaporimeter to the field of ophthalmology [in Japanese] J Jpn Contact Lens Soc 22,101-107
  7. Holly, FJ. (1980) Tear film physiology Am J Optom Physiol Opt 57,252-257[Medline][Order article via Infotrieve]
  8. Mishima, S, Maurice, DM. (1961) The oily layer of the tear film and evaporation from the corneal surface Exp Eye Res 1,39-45[Medline][Order article via Infotrieve]
  9. Tiffany, JM. (1985) The role of meibomian secretion in the tears Trans Ophthalmol Soc UK 104,396-401
  10. Driver, PJ, Lemp, MA. (1996) Meibomian gland dysfunction Surv Ophthalmol 40,343-367[Medline][Order article via Infotrieve]
  11. Tiffany, JM. (1987) The lipid secretion of the meibomian glands Adv Lipid Res 22,1-62[Medline][Order article via Infotrieve]
  12. Rieger, G. (1992) The importance of the precorneal tear film for the quality of optical imaging Br J Ophthalmol 76,157-158[Abstract/Free Full Text]
  13. Liu, Z, Pflugfelder, SC. (1999) Corneal surface regularity and the effect of artificial tears in aqueous tear deficiency Ophthalmology 106,939-943[CrossRef][Medline][Order article via Infotrieve]
  14. van Bijsterveld, OP. (1969) Diagnostic tests in the Sicca syndrome Arch Ophthalmol 82,10-14[Abstract/Free Full Text]
  15. Lemp, MA. (1995) Report of the National Eye Institute/Industry workshop on Clinical Trials in Dry Eyes CLAO J 21,221-232[Medline][Order article via Infotrieve]
  16. Sakamoto, R, Bennett, ES, Henry, VA, et al (1993) The phenol red thread tear test: a cross-cultural study Invest Ophthalmol Vis Sci 34,3510-3514[Abstract/Free Full Text]
  17. Yokoi, N, Bron, AJ, Tiffany, JM, Kinoshita, S. (2000) Reflective meniscometry: a new field of dry eye assessment Cornea 19,S37-S43[CrossRef][Medline][Order article via Infotrieve]
  18. Xu, KP, Yagi, Y, Toda, I, Tsubota, K. (1995) Tear function index: a new measure of dry eye Arch Ophthalmol 113,84-88[Abstract/Free Full Text]
  19. Ono, M, Yagi, Y, Goto, E, Yang, HY, Tsubota, K. (1998) Evaluation of Schirmer tests by two types of tear clearance tests Adv Exp Med Biol 438,869-873[Medline][Order article via Infotrieve]
  20. Prabhasawat, P, Tseng, SC. (1998) Frequent association of delayed tear clearance in ocular irritation Br J Ophthalmol 82,666-675[Abstract/Free Full Text]
  21. Yokoi, N, Takehisa, Y, Kinoshita, S. (1996) Correlation of tear lipid layer interference patterns with the diagnosis and severity of dry eye Am J Ophthalmol 122,818-824[Medline][Order article via Infotrieve]
  22. Yokoi, N, Mossa, F, Tiffany, JM, Bron, AJ. (1999) Assessment of meibomian gland function in dry eye using meibometry Arch Ophthalmol 117,723-729[Abstract/Free Full Text]
  23. Korb, DR, Greiner, JV. (1994) Increase in tear film lipid layer thickness following treatment of meibomian gland dysfunction Adv Exp Med Biol 350,293-298[Medline][Order article via Infotrieve]
  24. King-Smith, PE, Fink, BA, Fogt, N. (1999) Three interferometric methods for measuring the thickness of layers of the tear film Optom Vis Sci 76,19-32[CrossRef][Medline][Order article via Infotrieve]
  25. Khamene, A, Negahdaripour, S, Tseng, SC. (2000) A spectral-discrimination method for tear-film lipid-layer thickness estimation from fringe pattern images IEEE Trans Biomed Eng 47,249-258[CrossRef][Medline][Order article via Infotrieve]
  26. Holly, FJ. (1973) Formation and rupture of the tear film Exp Eye Res 15,515-525[CrossRef][Medline][Order article via Infotrieve]
  27. Holly, FJ. (1973) Formation and stability of the tear film Int Ophthalmol Clin 13,73-96[Medline][Order article via Infotrieve]
  28. Hykin, PG, Bron, AJ. (1992) Age-related morphological changes in lid margin and meibomian gland anatomy Cornea 11,334-342[Medline][Order article via Infotrieve]
  29. Robin, JB, Jester, JV, Nobe, J, Nicolaides, N, Smith, RE. (1985) In vivo transillumination biomicroscopy and photography of meibomian gland dysfunction: a clinical study Ophthalmology 92,1423-1426[Medline][Order article via Infotrieve]
  30. Chew, CK, Jansweijer, C, Tiffany, JM, Dikstein, S, Bron, AJ. (1993) An instrument for quantifying meibomian lipid on the lid margin: the meibometer Curr Eye Res 12,247-254[Medline][Order article via Infotrieve]
  31. Korb, DR, Baron, DF, Herman, JP, et al (1994) Tear film lipid layer thickness as a function of blinking Cornea 13,354-359[CrossRef][Medline][Order article via Infotrieve]
  32. Lee, SH, Tseng, SC. (1997) Rose bengal staining and cytologic characteristics associated with lipid tear deficiency Am J Ophthalmol 124,736-750[Medline][Order article via Infotrieve]
  33. Mathers, WD. (1993) Ocular evaporation in meibomian gland dysfunction and dry eye Ophthalmology 100,347-351[Medline][Order article via Infotrieve]
  34. Goto, E, Shimazaki, J, Monden, Y, et al (2002) Low-concentration homogenized castor oil eye drops for noninflamed obstructive meibomian gland dysfunction Ophthalmology 109,2030-2035[CrossRef][Medline][Order article via Infotrieve]
  35. Endo, K, Suzuki, N, Hoshi, M, et al (2001) The evaluation of epoxy resin coated quartz crystal humidity sensor and the measurement of water evaporation from human surfaces Hyomen Gijutsu 52,708-712
  36. Tsubota, K, Hata, S, Okusawa, Y, et al (1996) Quantitative videographic analysis of blinking in normal subjects and patients with dry eye Arch Ophthalmol 114,715-720[Abstract/Free Full Text]
  37. Toda, I, Tsubota, K. (1993) Practical double vital staining for ocular surface evaluation (Letter) Cornea 12,366-367[CrossRef][Medline][Order article via Infotrieve]
  38. Tsubota, K, Goto, E, Fujita, H, et al (1999) Treatment of dry eye by autologous serum application in Sjogren’s syndrome Br J Ophthalmol 83,390-395[Abstract/Free Full Text]
  39. Korb, DR, Greiner, JV, Glonek, T, et al (1996) Effect of periocular humidity on the tear film lipid layer Cornea 15,129-134[CrossRef][Medline][Order article via Infotrieve]
  40. Shine, WE, McCulley, JP. (1998) Keratoconjunctivitis sicca associated with meibomian secretion polar lipid abnormality Arch Ophthalmol 116,849-852[Abstract/Free Full Text]
  41. Shine, WE, McCulley, JP. (1991) The role of cholesterol in chronic blepharitis Invest Ophthalmol Vis Sci 32,2272-2280[Abstract/Free Full Text]
  42. Shine, WE, McCulley, JP. (1993) Role of wax ester fatty alcohols in chronic blepharitis Invest Ophthalmol Vis Sci 34,3515-3521[Abstract/Free Full Text]
  43. Shine, WE, McCulley, JP. (1996) Meibomian gland triglyceride fatty acid differences in chronic blepharitis patients Cornea 15,340-346[CrossRef][Medline][Order article via Infotrieve]
  44. Greiner, JV, Glonek, T, Korb, DR, Booth, R, Leahy, CD. (1996) Phospholipids in meibomian gland secretion Ophthalmic Res 28,44-49
  45. Greiner, JV, Glonek, T, Korb, DR, Leahy, CD. (1996) Meibomian gland phospholipids 15,371-375
  46. Rolando, M, Refojo, MF, Kenyon, KR. (1983) Increased tear evaporation in eyes with keratoconjunctivitis sicca Arch Ophthalmol 101,557-558[Abstract/Free Full Text]
  47. Mathers, WD, Lane, JA. (1998) Meibomian gland lipids, evaporation, and tear film stability Adv Exp Med Biol 438,349-360[Medline][Order article via Infotrieve]



This article has been cited by other articles:


Home page
Br J OphthalmolHome page
M Souchier, C Joffre, S Gregoire, L Bretillon, A Muselier, N Acar, J Beynat, A Bron, P D'Athis, and C Creuzot-Garcher
Changes in meibomian fatty acids and clinical signs in patients with meibomian gland dysfunction after minocycline treatment
Br J Ophthalmol, June 1, 2008; 92(6): 819 - 822.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
S. Khanal, A. Tomlinson, A. McFadyen, C. Diaper, and K. Ramaesh
Dry Eye Diagnosis
Invest. Ophthalmol. Vis. Sci., April 1, 2008; 49(4): 1407 - 1414.
[Abstract] [Full Text] [PDF]


Home page
Br J OphthalmolHome page
C Joffre, M Souchier, S Gregoire, S Viau, L Bretillon, N Acar, A M Bron, and C Creuzot-Garcher
Differences in meibomian fatty acid composition in patients with meibomian gland dysfunction and aqueous-deficient dry eye
Br J Ophthalmol, January 1, 2008; 92(1): 116 - 119.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
D. T.-S. Liu, M. A. Di Pascuale, J. Sawai, Y.-Y. Gao, and S. C. G. Tseng
Tear Film Dynamics in Floppy Eyelid Syndrome
Invest. Ophthalmol. Vis. Sci., April 1, 2005; 46(4): 1188 - 1194.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Goto, E.
Right arrow Articles by Tsubota, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Goto, E.
Right arrow Articles by Tsubota, K.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS