|
|
||||||||
From the Department of Ophthalmology, Nagoya City University Medical School, Nagoya, Japan.
| Abstract |
|---|
|
|
|---|
METHODS. The intrascleral implant (0.5 mm thick and 4 mm in diameter) was made of poly(DL-lactide) containing 25% betamethasone phosphate. The in vitro release of BP from the implant was evaluated by high-performance liquid chromatography (HPLC). The implants were placed into a scleral pocket in the rabbits eye. The concentrations of BP in the aqueous humor, vitreous, and retina-choroid were measured by HPLC. The toxicity and biocompatibility of the implant were evaluated by slit lamp examination, electroretinography, and light microscopy.
RESULTS. In vitro studies demonstrated that the implants released BP in a biphasic pattern for at least 8 weeks. The BP concentrations in the vitreous and the retina-choroid remained within the concentration range capable of suppressing inflammatory responses for more than 8 weeks. The BP concentration was greater in the retina-choroid than in the vitreous. In the aqueous humor, BP was below the detection limit during the observation period. No significant toxicity to the retina was observed. Also, the implant showed good biocompatibility in the eye.
CONCLUSIONS. These results suggest that the intrascleral implant would be a promising system for delivery of steroid to the posterior segment of the eye.
It has been hypothesized that transscleral delivery is an effective method of achieving therapeutic concentrations of drugs in the posterior part of the eye.1 2 3 4 With its large surface area and high degree of hydration, the sclera is permeable to solutes of a wide range of molecular weights.2 4 5 Subconjunctival or peribulbar injection is a means of transscleral drug delivery, and it can provide a higher intravitreous or subretinal concentration of the drug than oral administration.6 7 8 9 However, extensive systemic absorption occurs with this method.
In this study, we used a biodegradable intrascleral implant containing betamethasone phosphate (BP) to evaluate its feasibility as a sustained intraocular drug delivery system. The device was implanted in the scleral pocket. We investigated the in vitro and in vivo release of BP from the implant and the safety of the implant in the rabbit eye.
| Materials and Methods |
|---|
|
|
|---|
Preparation of the Intrascleral Implant
The intrascleral implant was prepared by dissolving 250 mg BP and 750 mg PLA in 20 mL of acetic acid. The resultant solution was frozen at -80°C and lyophilized for 48 hours to obtain a homogeneous cake. Seventy-five milligrams of the cake was placed in a stainless mold for infrared analysis (P/N202-32010; Shimadzu, Kyoto, Japan) and compressed by a press (SSP-10; Shimadzu) under reduced pressure at the weight of 10 tons for 5 minutes. A disc (thickness: 0.5 mm, diameter: 13 mm) was obtained. The disc for an intrascleral implant was then stamped out from this disc. The intrascleral implant weighed approximately 7 mg and was 0.5 mm thick and 4 mm in diameter (Fig. 1) . The intrascleral implant had a BP loading of 25% wt/vol.
|
In Vivo Release Study
We used 20 eyes of 20 pigmented rabbits, weighing 2.0 to 2.5 kg each. The animals were treated in accordance with the ARVO Statement for the Use of Animals in Ophthalmic and Vision Research.
The rabbits were anesthetized with a mixture of xylazine hydrochloride (2 mg/kg) and ketamine hydrochloride (5 mg/kg). The ocular surface was then anesthetized with a topical instillation of 0.4% oxybuprocaine hydrochloride. After the sclera was exposed, a scleral pocket was made at the depth of about one-half the total scleral thickness (
100 µm) with a crescent knife 2 mm from the limbus. The intrascleral implant was inserted in the scleral pocket (Fig. 2) . The scleral and conjunctival wounds were sutured with 7-0 silk. Animals were killed with an overdose of intravenous pentobarbital sodium at 1, 2, 4, and 8 weeks after implantation, and four eyes were immediately enucleated at each time point. The implants and the aqueous humor were retrieved from the enucleated eyes, and the remaining tissues were frozen at -85°C. The vitreous and the retina/choroid were removed by razor from the frozen eyes. The concentrations of BP in the implants and samples of ocular tissues (aqueous humor, vitreous, and retina/choroid) were determined by HPLC.
|
Toxicity Study of the Implant
Clinical Observations.
Slit lamp examination, measurement of intraocular pressure, and indirect ophthalmoscopy were performed to evaluate the possible toxic effect of the implant before implantation and at 1, 2, 4, 8, 12, and 16 weeks after implantation.
Electrophysiological Evaluation.
Scotopic electroretinography (ERG) was performed on both eyes of each of four rabbits at baseline and 1, 2, 4, and 8 weeks after placement of the implant. The electroretinographic responses (ERG-50; Kowa Co., Ltd, Nagoya, Japan) were analyzed by dividing the b-wave amplitude recorded from eyes with the implants by those recorded from the contralateral control eyes.
Histopathologic Examination.
Possible adverse effects of the intrascleral implant on ocular tissues were evaluated by light microscopy. At 16 weeks after implantation, when the implants appeared to have completely degraded, four eyes were enucleated after rabbits were killed with an overdose of pentobarbital sodium. The eyes were immersed in a mixture of 4% glutaraldehyde and 2.5% neutral buffered formalin for 24 hours. Globes were opened at the equator and divided into anterior and posterior segments. The cut specimens were dehydrated, infiltrated, embedded in paraffin, and sectioned with a microtome. Sections were stained with hematoxylin and eosin.
Statistical Analysis
A paired Students t-test was used to compare the ERG b-wave amplitude ratio before and after implantation. Results were considered statistically significant at P < 0.05.
| Results |
|---|
|
|
|---|
|
|
|
Electrophysiological Evaluation
Right-to-left ratios of the scotopic b-wave showed no statistically significant difference between baseline and each time point (P > 0.09; Fig. 6 ).
|
|
| Discussion |
|---|
|
|
|---|
The profile of in vitro BP released from the implant showed a biphasic release pattern, with an initial burst and a second stage derived from diffusional release. This profile was similar to that of a biodegradable plug-shaped scleral implant containing BP, which we previously reported.10 The initial burst may have been due to the rapid release of the drug deposited on the implant surface and in the water channels in the matrix. The second release phase showed slow drug release, possibly controlled by the degradation speed of the polymer. The initial burst was reduced to almost half as much as that of the plug-shaped device with the same loading of the drug. This finding was probably due to the compression process of the implant. During the next diffusive phase, the implant continued releasing BP for approximately 50 days. The drug release could be controlled by changing the drug loading and the molecular weight of the polymers (data not shown), as was seen in biodegradable plug-shaped scleral implants.10 11 12 13 14
In contrast to the in vitro release profile, the in vivo implant released approximately 8% of the drug for 1 week with no initial burst effect. Thereafter, the implant released the drug faster than it did in vitro. The surrounding environment of the implant in the sclera may not be the same sinking condition as that in vitro. At the early stage, water absorption of the implant may be less than that in vitro, resulting in no rapid release of the drug from the implant. In this condition, the water channels may not be well developed in the matrix. Also, the pH inside the implant may decrease, which enhances autocatalysis at the center of the polymer matrix.15 16 17 Finally, the drug may release rapidly after the establishment of communication between the inside and the outside. This difference between in vitro and in vivo conditions has to be taken into consideration in this system.
Transscleral drug delivery has been hypothesized to be an effective means of achieving therapeutic concentrations of drugs in the posterior part of the eye.1 2 3 4 It has been reported that scleral permeability is comparable to that of the corneal stroma.18 As in the corneal stroma, the primary route for solute transport through the sclera is by passive diffusion through an aqueous pathway. The rabbit sclera is permeable to solutes ranging in molecular weight up to 150 kDa, and the permeability declines exponentially with increasing molecular weight and molecular radius.2 In this study, BP permeated the sclera fairly well. BP has a small molecular weight of 516 Da, and the device containing BP was inserted into the scleral pocket, which enhances permeation of BP through the thinned sclera. Olsen et al.19 have reported that the permeation of dexamethasone through the sclera with surgical thinning is significantly higher than through sclera without surgical thinning. The scleral permeability to BP in the rabbit may be higher than that in the human since the rabbit sclera is thinner than the human sclera. However, it has been reported that the scleral permeability to small molecules between human and rabbit is not significantly different.20 The retinal pigment epithelium (RPE), which is the outer blood-retina barrier, is between the choroid and the retina. The RPE has tight junctions of the nonleaky type and has low permeability to many compounds.21 BP may pass through the paracellular spaces by passive diffusion.
The BP levels in the retina/choroid and vitreous showed a slow decline from week 2 to week 8, although the decline in drug release into the intrascleral space was greater over this period. In an intravitreal BP release system using a plug-type implant, BP concentration was higher in the retina/choroid than in the vitreous at all times. Presumably, BP may not distribute by simple diffusion in the eye, and the clearance of the drug in the retina/choroid may be much slower than in the vitreous. Accumulation of the drug in the retina/choroid has to be taken into consideration in intraocular drug delivery systems. Furthermore, in this study, we only measured BP concentrations. Betamethasone phosphate is metabolized into betamethasone by hydrolysis. The disparity between the drug levels in the tissue and drug release from the implant may come from these factors.
McCartney et al.22 have postulated the existence of a transscleral route of corticosteroid penetration into the rabbit eye after subconjunctival injection. Recently, Weijtens et al.6 7 8 reported several series of studies on the concentration of dexamethasone in vitreous and serum by three different administration routes: subconjunctival injection, peribulbar injection, and oral administration. In these studies, dexamethasone disodium phosphate and dexamethasone were used for subconjunctival or peribulbar injection and for oral administration, respectively. Serum levels after subconjunctival and peribulbar injection are comparable to those achieved by a high oral dose. The higher intravitreous concentration after subconjunctival injection or peribulbar injection is caused by diffusion from the serum and additional transscleral diffusion. Betamethasone may show kinetics in the eye similar to those of dexamethasone, because it is a stereoisomer of dexamethasone. Furthermore, its effective concentrations for suppressing various inflammatory processes (0.154.00 µg/mL)23 24 25 26 27 28 are thought to be the same as dexamethasone.
One of the most advantageous aspects of this system is that the device releases the drug continuously in the sclera. It is reported that the lag time for solute diffusion across the sclera is similar to or actually longer than the drug-sclera contact time during conventional administration of the drug.4 Although only part of the drug diffuses across the sclera after subconjunctival or peribulbar injection, most of the drug is absorbed systemically.6 7 8 9 To achieve therapeutic concentration in the vitreous, multiple injections may be needed, resulting in local and general side effects from the drug. This intrascleral sustained drug delivery system would permit drug flux and minimize systemic absorption of the drug by the conjunctival vasculature.
In terms of intraocular steroid delivery systems, a few systems have already been used clinically. Intravitreous sustained delivery devices, which release dexamethasone or fluocinolone acetonide, have been successfully used to treat severe uveitis.29 30 The structure of these devices is very similar to the ganciclovir implant (Vitrasert; Bausch & Lomb Surgical, San Dimas, CA),31 32 in which the drug release rate is controlled by the membrane of poly(vinyl alcohol). The 2-mg fluocinolone acetonide device can release the drug at a constant rate for more than 2.5 years.30 In this system, the kinetics of the drug in the vitreous may be predictable because the drug is released from the device directly in the vitreous humor. In contrast, the kinetics of the drug in our system depends mainly on physical and chemical characteristics of the drug, such as molecular weight or water solubility. Probably, the drugs that can be applied to the intrascleral implant are limited.
In our studies, the scleral implant appeared to be biocompatible. No substantial toxic reactions were observed electrophysiologically or histologically. In conclusion, our results suggest that this new intrascleral drug delivery system involving an implantable biodegradable polymer device may have usefulness in treating vitreoretinal disorders. Because advanced safety and effectiveness of the intrascleral implant must be ensured in clinical application, further investigations are needed.
| Footnotes |
|---|
Submitted for publication April 15, 2002; revised August 12, 2002; accepted September 23, 2002.
Commercial relationships policy: N.
The publication costs of this article were defrayed in part by page charge payment. This article must therefore be marked "advertisement" in accordance with 18 U.S.C.
1734 solely to indicate this fact.
Corresponding author: Yuichiro Ogura, Department of Ophthalmology, Nagoya City University Medical School, Mizuho-ku, Nagoya, Aichi 4678601, Japan; ogura{at}med.nagoya-cu.ac.jp.
| References |
|---|
|
|
|---|
-hydroxy acids) in aqueous media. Part 1: poly(DL-lactic acid) J Mater Sci Mater Med 1,123-130
-hydroxy acids) in aqueous media. Part 2. Degradation of lactide-glycolide copolymers, PLA37.5GA25 and PLA75GA25 J Mater Sci Mater Med 1,131-139
-hydroxy acids) in aqueous media. Part 3. Influence of the morphology of poly(L-lactic acid) J Mater Sci Mater Med 1,198-206[CrossRef]
-interferon messenger RNA J Immunol 133,272-276
, and the IL 2 receptor by human peripheral blood lymphocytes J Immunol 136,4503-4508[Abstract]
This article has been cited by other articles:
![]() |
A. Silva-Cunha, S. L. Fialho, M.-C. Naud, and F. Behar-Cohen Poly-{epsilon}-Caprolactone Intravitreous Devices: An In Vivo Study Invest. Ophthalmol. Vis. Sci., May 1, 2009; 50(5): 2312 - 2318. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. G. Short Safety Evaluation of Ocular Drug Delivery Formulations: Techniques and Practical Considerations Toxicol Pathol, January 1, 2008; 36(1): 49 - 62. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Kim, C. J. Galban, R. J. Lutz, R. L. Dedrick, K. G. Csaky, M. J. Lizak, N. S. Wang, G. Tansey, and M. R. Robinson Assessment of Subconjunctival and Intrascleral Drug Delivery to the Posterior Segment Using Dynamic Contrast-Enhanced Magnetic Resonance Imaging Invest. Ophthalmol. Vis. Sci., February 1, 2007; 48(2): 808 - 814. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. C. Gilger, J. H. Salmon, D. A. Wilkie, L. P. J. Cruysberg, J. Kim, M. Hayat, H. Kim, S. Kim, P. Yuan, S. S. Lee, et al. A novel bioerodible deep scleral lamellar cyclosporine implant for uveitis. Invest. Ophthalmol. Vis. Sci., June 1, 2006; 47(6): 2596 - 2605. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Okabe, H. Kimura, J. Okabe, A. Kato, H. Shimizu, T. Ueda, S. Shimada, and Y. Ogura Effect of Benzalkonium Chloride on Transscleral Drug Delivery Invest. Ophthalmol. Vis. Sci., February 1, 2005; 46(2): 703 - 708. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kato, H. Kimura, K. Okabe, J. Okabe, N. Kunou, and Y. Ogura Feasibility of Drug Delivery to the Posterior Pole of the Rabbit Eye with an Episcleral Implant Invest. Ophthalmol. Vis. Sci., January 1, 2004; 45(1): 238 - 244. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Okabe, H. Kimura, J. Okabe, A. Kato, N. Kunou, and Y. Ogura Intraocular Tissue Distribution of Betamethasone after Intrascleral Administration Using a Non-biodegradable Sustained Drug Delivery Device Invest. Ophthalmol. Vis. Sci., June 1, 2003; 44(6): 2702 - 2707. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |