1From the Retina Foundation of the Southwest, Dallas, Texas; the 2Department of Ophthalmology, University of Texas Southwestern Medical Center, Dallas, Texas; and the 3Glaucoma Institute, State University of New York (SUNY) College of Optometry, New York, New York.
| Abstract |
|---|
|
|
|---|
METHODS. Foveal S-cone increment thresholds were measured on adapting backgrounds ranging from 1.17 to 4.17 log troland (Td) and from -0.16 to 3.66 log S-cone trolands (TdS). Within-session variability (slope of the psychometric function) was evaluated in 2 trained and 15 inexperienced normal observers. Testretest variability was evaluated in the 2 trained observers, and interobserver variability in the group of 15 observers. Multiple linear regression was used to model the effects of log luminance, log S-cone adaptation, and second-site polarization (ratio of luminance and S-cone adaptation; log [Td/TdS]).
RESULTS. Testretest variability was lower for conditions with higher levels of S-cone adaptation (F = 9.04, P = 0.013, for the trained observers). Adaptation conditions with lower levels of polarization were associated with lower within-session variability (F = 6.9, P = 0.011; trained observers) and interobserver variability (F = 33.7, P = 0.004; group of 15 observers).
CONCLUSIONS. Variability of S-cone increment thresholds can be reduced by using adaptation conditions with a higher level of S-cone adaptation and/or a more balanced ratio between luminance and S-cone adaptation than is used for SWAP.
An empiric observation has been that SWAP thresholds show higher variability than thresholds from conventional, achromatic, automated perimetry. Testretest variability is higher in SWAP than in achromatic perimetry, both in normal subjects11 and in patients with glaucoma or ocular hypertension.12 13 Also, interobserver variability14 15 is higher in SWAP than in achromatic perimetry, even after correction for preretinal absorption of light from the short-wavelength target. These findings are unfortunate in situations in which statistical significance of quantitative SWAP results is crucial, such as early detection or measuring progression of visual field defects, both in ophthalmic practice and in clinical studies.
The cause of the increased variability in SWAP remains unclear, but may be due either to differences in intrinsic properties between the S-cone pathways and the luminance pathways, or to properties of the test conditions. Of note, review of published S-cone threshold data shows high variability in some studies,11 12 13 14 15 16 but not in all.17 18 19 This suggests that the increased variability in SWAP may be due to the test conditions used to measure S-cone sensitivity rather than to intrinsic properties of the S-cone pathway. In fact, the studies that did not show increased variability in S-conemediated detection thresholds were all performed under conditions of approximately equal adaptation of L-, M-, and S-cones. This is in contrast with SWAP, in which a middle-wavelength background desensitizes (i.e., adapts) the L- and M-cones while leaving the S-cones relatively unadapted.20 As a result, in SWAP, the visual system operates in a range in which S-cone sensitivity is near absolute threshold and, furthermore, in which there is a large imbalance between S-cone adaptation and L- and M-cone adaptation. This imbalance, in turn, could cause the color-opponent "second site" of S-cone visual processing to be considerably polarized,21 22 23 24 which may increase the variability of detection thresholds.
Herein, we present S-cone increment threshold data obtained under a range of adaptation conditions. This study was undertaken in an attempt to determine whether threshold variability can be affected by the level of S-cone adaptation and/or the level of luminance adaptation (adaptation of the L- and M-cones). Based on the results, we suggest that threshold variability can be reduced by measuring S-cone increment thresholds in relatively neutral adaptation conditions (i.e., when there is less imbalance between luminance and S-cone adaptation).
| Methods |
|---|
|
|
|---|
= 200 ms) of the target was produced by the variable attenuator (maximum attenuation 3 log units), and the ND filter wheel provided up to 4 log units of attenuation of the increments. The variable attenuator and the ND filter wheel were controlled by a microcomputer (Apple, Cupertino, CA) equipped with a 12-bit digital-to-analog converter, a timing board (DMA-8), and a digital input-output board (National Instruments, Austin, TX). The two channels were combined by a beam splitter. A chin rest and a rubber eyepiece enabled the observer to maintain a steady viewing position.
Calibration and Units
The retinal illuminance of all monochromatic target and background lights was measured with a photometer and a photometric probe (UDT Sensors, Hawthorne, CA) which together were accurate to within 5% for all visible wavelengths, and expressed in trolands (Td) according to the method of Nygaard and Frumkes.25 The level of adaptation of the S-cones was defined by using the model of Boynton and Kambe26 for cone-specific trolands. This model is based on the Judd standard observer and postulates that equal-energy white of 1 Td retinal illuminance results in S-cone excitation of 1 S-cone troland (1 TdS). S-cone trolands were calculated using equations provided by Miyahara et al.27
Whereas all increment thresholds were measured in fractions (e.g., log[
Td/Td]), we converted the values for variability to a decilog scale (decibel units; 1 dB = 0.1 log), which is the scale commonly used in static perimetry.
Stimuli, Threshold Measurements, and Adaptation Conditions
Increment thresholds were determined for a foveal 460-nm target, presented on a series of monochromatic backgrounds of various wavelengths and intensities. A two-interval forced-choice staircase was used with 20 reversals and a two-down/one-up rule. Target luminance changed in 0.3-log steps until the second reversal and in 0.15-log steps thereafter. This resulted in staircases of typically 80 to 100 trials. Using maximum likelihood estimation, data from each staircase were fit with a three-parameter Weibull psychometric function
![]() |
(75% correct point), slope ß, and upper asymptote
. This combination of staircase method and fitting technique has been shown to provide reliable estimates of threshold.28 Observers adapted to the background for approximately 2 minutes before each staircase. Between staircases, the color and intensity of the background were changed to obtain data for six different adaptation conditions, chosen to span at least a 3-log unit range of luminance adaptation (retinal illuminance ranging from 1.17 to 4.17 log Td) as well as S-cone adaptation states (-0.16 to 3.66 log TdS; Table 1 ). This also provided a range of ratios of luminance and S-cone adaptation. This ratio is termed (second-site) "polarization"21 22 herein, designates luminance adaptation relative to S-cone adaptation, and is expressed as log(Td/TdS). Polarization ranged from 0.51 to 3.29 log(Td/TdS). In the diagram of Figure 1 , where log luminance adaptation is plotted against log S-cone adaptation for each condition, polarization varies along an oblique axis, as indicated. Note that conditions A and B have equal polarization, as do conditions E and F, and that condition D is similar to the conditions used for SWAP.
|
|
Observers
Data are presented from 2 trained normal observers (the authors), and from a group of 15 inexperienced volunteer observers free of cataract or other known eye disease, having normal acuity and contrast sensitivity as measured with the Regan contrast sensitivity charts, and having normal color vision as measured with the Ishihara, SPP-II, FM 100-hue, and Adams desaturated D-15 tests and anomaloscopy. Their age range, 36 to 77 years (mean, 61 ± 10 [SD]), typically is of interest in studies of glaucoma. All observers met the conservative criteria, which ensured detection of the 460-nm target by S-cones without intrusion of the L - M or L + M mechanisms (in condition A) or the rod mechanism (in condition E). Their 460/490 ratio ranged from 0.52 to 0.84 log unit in condition A, and from 0.70 to 1.32 log unit in condition E. Six additional naive observers (age 62 ± 3 years) were tested who met the same clinical inclusion criteria, but their 460/490 ratios were very close to the upper limit (0.46 log unit) for which a red-green opponent (L - M) mechanism may mediate detection of the 460 nm stimulus. For all six observers this was apparently due to a combination of relatively low S-cone sensitivity and relatively high L - M sensitivity. They were excluded from the study.
All measurements were performed on the observers preferred eye. Written informed consent was obtained from all observers. This research followed the tenets of the Declaration of Helsinki and was approved by the Institutional Review Board of the University of Texas Southwestern Medical Center.
Data Analysis
All threshold measurements were expressed in logarithmic units. The effects of age on log threshold were analyzed in the group of 15 observers using one-way analysis of variance (ANOVA).
Three types of variability in S-cone increment thresholds were studied. For a measure of within-session variability, log ß, characterizing the slope of the psychometric function, was determined in the 2 trained observers and in the group of 15 inexperienced observers. Thus, within-session variability reflects short-term fluctuations in sensitivity in a single test location over the time-span of the experimental session. (Note that higher values of log ß correspond to steeper psychometric functions and lower variability.) Testretest variability was defined as the SD of log threshold from five staircases in each condition, expressed in decibels. For each of the two trained observers a full set of staircases was run five times on different days in a time span of 2 weeks, with the order of test conditions randomized on each day. Finally, interobserver variability was defined as the SD of log threshold across the group of 15 observers, expressed in decibels.
It was not possible to treat S-cone adaptation, luminance adaptation, and polarization simultaneously as independent variables because these three are not independent. Therefore, for each type of variability, a multiple linear regression analysis was performed to model the effects of S-cone adaptation, luminance adaptation, and (when possible) observer and age. A backward stepwise regression model determined which of these independent variables were significantly associated with variability at the
= 0.05 level. If both S-cone adaptation and luminance adaptation yielded significant regression coefficients with opposite signs, suggesting a significant effect of polarization, the regression analysis was repeated, with polarization replacing S-cone adaptation and luminance adaptation as the independent variable.
All analyses were performed on computer (MiniTab Statistical Software; Minitab Corp., State College, PA).
| Results |
|---|
|
|
|---|
|
|
|
TestRetest Variability
Testretest variability, defined as the SD of log threshold across five repetitions (expressed in dB), was studied for the two trained observers. Multiple regression of testretest variability on luminance adaptation, S-cone adaptation, and observer indicated a significant effect from S-cone adaptation (t = -2.67, P = 0.028), but not from luminance adaptation (t = 0.04, P = 0.97) or observer (t = 1.33, P = 0.22). Subsequent omission of luminance adaptation and observer from the analysis resulted in the regression equation, Testretest variability (in dB) = 1.03 - 0.17 x (log S-cone adaptation) (F(1,10) = 9.04, P = 0.013), indicating that testretest variability decreases for adaptation conditions with higher levels of S-cone adaptation. This relationship is illustrated in Figure 4 , where the testretest reliability is plotted against S-cone adaptation for each of the six conditions, for each of the two observers.
|
|
| Discussion |
|---|
|
|
|---|
This study was not primarily designed to investigate the effects of aging. Nevertheless, a fairly wide range of ages was present among the observers. Log threshold was found to be associated with age in conditions A, E, and F and to some extent in condition D, with the average amount of threshold increase ranging from 0.116 to 0.210 dB/year (Table 2) . This confirms published findings by Eisner et al.35 for foveal conditions quite similar to our condition D (S-cone increments on a 580-nm, 3.0-log Td background), by Johnson et al.36 for peripheral (central 30°) S-cone increments on low and high intensity broad-band yellow backgrounds, and by Remky et al.37 for perifoveal (central 10°) S-cone increments on a 594-nm, 3.7-log Td background. We must conclude therefore that part of the interobserver variability in the present study is probably explained by age. In addition to the observed increase of log S-cone threshold with age, Johnson et al.36 also reported an increase of interobserver variability in log S-cone threshold data for subjects aged more than 60 years. They attribute this to an increased interobserver variability in lens density.31 We will point out in the discussion to follow, as has been argued before (e.g., Refs. 14 15 20 ), that the magnitude of the effects of interobserver variability in lens density, pupil diameter, and the sensitivity of the cone mechanisms on perimetric thresholds is strongly dependent on the adaptation state of the visual system.
Published data on point-wise normal perimetric variability under conventional, achromatic, adaptation conditions vary among studies, and reported data are on the order of 1 dB for within-session variability,11 38 on the order of 2 dB for testretest variability,11 39 40 and approximately 2 to 5 dB for interobserver variability.14 Variation in the results from different studies is presumably due in part to differences in methods of analysis. More pertinent to our findings, however, is the comparison of normal threshold variability between conventional perimetry and SWAP within single studies, which have shown a 1.6-fold lower within-session variability,11 a 2.1-fold lower testretest variability,11 and a 1.9-fold lower interobserver variability14 for conventional perimetry. These values correspond well with the current findings. The size of the effects observed (i.e., the change in variability across conditions) corresponded to a factor of 1.5 for within-session variability (from 4.0 to 5.8 dB, after converting the parameter ß to the SD [in decibels] of a cumulative Gaussian function41 ; Fig. 3 , inset). Testretest variability varied 2.6-fold (from 0.411.06 dB; Fig. 4 ), and interobserver variability varied 1.8-fold (from 2.14 to 3.86 dB; Fig. 5 ) across conditions.
Typically, psychophysical techniques show less variability when increment thresholds are measured (such as in conventional achromatic perimetry) than when absolute thresholds are measured (such as in dark-adapted perimetry42 43 or in measurements of dark adaptation). Part of the explanation is that, if the visual system operates at an adaptation level at which Webers law holds, increment threshold is proportional to the intensity of the background. As a result, thresholds are only minimally affected by fluctuations in the observers pupil size or cone sensitivity or by variations in lens density across observers. Absolute thresholds, in contrast, are directly affected by all three factors.
The mean threshold data show a pattern similar to that found by Yeh et al.24 When plotted as log S-cone increments as a function of log S-cone adaptation (as in Fig. 2B ), thresholds obtained at a fixed luminance level follow Webers law for relatively high levels of S-cone adaptation (where the data points fall on a line of slope = 1), but not for lower S-cone adaptation levels (where the data level off to fall on a horizontal line). The curves in the Figure 2B are S-cone tvi functions that show the transition from constant threshold behavior at lower S-cone adaptation levels to Weber-like behavior for higher S-cone adaptation levels. For different luminance levels, these S-cone tvi functions are shifted along a 45° angle, which Yeh et al. interpreted in terms of second-site adaptation.
The Yeh et al.24 model was a modification of the chromatic discrimination model of Boynton and Kambe,26 which included gain control mechanisms that allowed fitting color discrimination data from a wider range of retinal illuminance. The Boynton and Kambe model, in turn, built on a long tradition of describing color discrimination thresholds in terms of opponent processing,21 22 44 45 that has been successful in capturing many aspects of classic color discrimination data. Our data are consistent with the data and the model of Yeh et al.,24 and extend them to higher mean retinal illuminances.
SWAP test conditions are close to our condition D (assuming a pupil diameter between 3 and 5 mm; Table 1 , Fig. 1 ) and must therefore be on the horizontal portion of an S-cone tvi function (Fig. 2B) . For SWAP, this implies that the adaptation condition is such that the S-cones are near absolute threshold, and that Webers law does not hold for S-cone increment thresholds. This probably increases variability above the level that might be found in the region where Webers law holds.
The primary purpose of this study was to gain insight into the underlying causes of the relatively high variability in SWAP. The results indicate that lower S-cone threshold variability can be achieved in conditions with higher levels of S-cone adaptation. It is often implicitly assumed that minimizing the variability of a clinical measure is a desirable goal. Indeed, we believe that this is justified for many clinical uses of perimetry, such as early detection or longitudinal measurement of the progression of visual field defects. However, by using adaptation conditions that are in the Weber region, the test becomes less sensitive to any disease action that has equal effects on the stimulus and the adapting field. Only by testing near absolute threshold can such an effect of disease action be observed. On the one hand, for such tests that operate outside the Weber region, it is crucial to control properly for preretinal light absorption and pupil diameter. On the other hand, increasing S-cone adaptation to ensure Weber-like behavior results in a smaller amount of isolation of S-cone mechanisms from L- and M-cone mechanisms. In fact, requirements of isolation and of variability seem to counteract each other, and the choice of S-cone adaptation level should therefore reflect a tradeoff between the two. Currently, SWAP test conditions have been optimized to yield good isolation, thereby producing relatively high variability. This should be kept in mind and, wherever possible, compensated for by increasing the number of stimulus presentations or visual field measurements.
In conclusion, we showed systematic effects of S-cone adaptation and second-site polarization on different types of variability in S-cone increment thresholds. Further research is needed to explore the magnitude of these effects systematically and to extend these findings to perifoveal test conditions relevant for perimetry.
| Footnotes |
|---|
Submitted for publication October 17, 2002; revised April 30, 2003; accepted May 18, 2003.
Disclosure: J. Felius, None; W.H. Swanson, None
The publication costs of this article were defrayed in part by page charge payment. This article must therefore be marked "advertisement" in accordance with 18 U.S.C.
1734 solely to indicate this fact.
Corresponding author: Joost Felius, Retina Foundation of the Southwest, 9900 N. Central Expressway, Suite 400, Dallas, TX 75231; jfelius{at}earthlink.net.
| References |
|---|
|
|
|---|
1 and
3 color mechanisms of Stiles Vision Res 19,293-312[CrossRef][Medline][Order article via Infotrieve]
This article has been cited by other articles:
![]() |
A. Eisner, M. D. Toomey, L. J. Incognito, J. P. O'Malley, and J. R. Samples Contrasting Blue-on-Yellow with White-on-White Visual Fields: Roles of Visual Adaptation for Healthy Peri- or Postmenopausal Women Younger Than 70 Years of Age Invest. Ophthalmol. Vis. Sci., December 1, 2006; 47(12): 5605 - 5614. [Abstract] [Full Text] [PDF] |
||||
![]() |
E D Gilmore, C Hudson, R K Nrusimhadevara, and P T Harvey Frequency of seeing characteristics of the short wavelength sensitive visual pathway in clinically normal subjects and diabetic patients with focal sensitivity loss Br. J. Ophthalmol., November 1, 2005; 89(11): 1462 - 1467. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |