IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2005;46:3208-3213.)
© 2005 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.04-1240

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tamburrelli, C.
Right arrow Articles by Salgarello, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tamburrelli, C.
Right arrow Articles by Salgarello, T.

Underestimate of Tonometric Readings after Photorefractive Keratectomy Increases at Higher Intraocular Pressure Levels

Ciro Tamburrelli, Andrea Giudiceandrea, Agostino Salvatore Vaiano, Carmela Grazia Caputo, Francesca Gullà, and Tommaso Salgarello

From the Institute of Ophthalmology, Catholic University, Rome, Italy.


    Abstract
 Top
 Abstract
 Materials and Methods
 Results
 Discussion
 References
 
PURPOSE. To determine whether tonometric readings of increases in intraocular pressure (IOP) during the water-drinking test (WDT) are affected by variations in central corneal thickness (CCT) induced by photorefractive keratectomy (PRK).

METHODS. Data from 30 randomly selected eyes of 30 patients (18 men and 12 women; mean age, ± SD: 33.9 ± 7.6 years) undergoing bilateral PRK for myopia (–6.57 ± 2.39 D) were obtained. Objective refraction, anterior radius of corneal curvature (R), CCT, and IOP measurements at baseline and at different time intervals after ingestion of 1 L of water within 5 minutes, were performed before and 6 months after PRK. All measured IOPs were recalculated by a correction factor for R and CCT and expressed as corrected intraocular pressure (IOPC) measurements.

RESULTS. The mean R ± SD was 7.84 ± 0.20 and 8.76 ± 0.34 mm, and the mean CCT was 544.83 ± 19.69 and 453.97 ± 29.95 µm, before and after PRK, respectively. The mean IOP at baseline was 15.05 ± 2.78 and 9.83 ± 2.56 mm Hg, and during WDT was 18.32 ± 3.42 and 11.42 ± 3.10 mm Hg at 10 minutes, 18.59 ± 2.99 and 11.54 ± 2.54 mm Hg at 20 minutes, 17.80 ± 2.85 and 10.87 ± 2.22 mm Hg at 30 minutes, 16.35 ± 3.02 and 10.26 ± 2.21 mm Hg at 45 minutes, and 14.90 ± 2.52 and 9.81 ± 2.32 mm Hg at 60 minutes, before and after PRK, respectively. The mean IOPC at baseline was 13.64 ± 2.33 and 13.05 ± 2.98 mm Hg, and during WDT was 16.61 ± 2.77 and 15.08 ± 3.59 mm Hg at 10 minutes, 16.96 ± 2.69 and 15.33 ± 2.96 mm Hg at 20 minutes, 16.10 ± 2.50 and 14.42 ± 2.60 mm Hg at 30 minutes, 14.92 ± 2.72 and 13.62 ± 2.65 mm Hg at 45 minutes, 13.82 ± 2.27 and 13.05 ± 2.55 mm Hg at 60 minutes, before and after excimer laser treatment, respectively. Pre- and postoperative IOPs and percentages of IOP increase differed significantly (P < 0.05), in particular at the peak, as did IOPCs but not the percentages of increase in IOPC, apart from the highest values.

CONCLUSIONS. Corneal changes after PRK for myopia may induce an uneven underestimate of the IOP increases. The inadequacy of a correction factor to compensate for CCT and R at high IOP levels indicates that other biomechanical factors may play a role when the cornea is subjected to dynamic actual IOP variation. Such increase of the well-known underestimate of IOP after PRK at higher actual IOPs may have significant clinical implications in tonometric assessment of subjects at risk of glaucomatous damage.


Recent evidence has stressed the clinical role of the assessment of central corneal thickness (CCT) for correct management of glaucoma,1 2 and pachymetry has been inserted in the current ophthalmologic practice for patients at risk of glaucoma. Indeed, Ehlers et al.3 and later Whitacre et al.4 reported that applanation tonometry provides accurate readings compared with actual intraocular pressure (IOP) only when CCT is 520 µm, whereas thinner and thicker corneas produce underestimations and overestimations of IOP, respectively.5 6 7 8 9 10

Reduction of tonometric readings has been reported in eyes after photorefractive keratectomy (PRK)11 12 13 14 and laser in situ keratomileusis (LASIK).15 16 17 These procedures flatten the anterior corneal surface and reduce CCT proportionally to the extent of myopia,14 18 providing lower IOPs compared with preoperative ones.

In a recent study,19 refractive surgery provided an excellent model for the in vivo study, in the same patient, of the effect of variations in CCT on the IOP readings after the administration of an ocular hypotensive drug. In their sample of myopic patients undergoing PRK, Tamburrelli et al.19 demonstrated that CCT reduction provides an erroneous impression of reduced pharmacologic efficacy, that may be avoided after correction of IOP by a proper nomogram.

The mentioned influence of CCT on IOP reduction readings suggested the present study, in which we evaluated whether similar findings occur in increased IOP as well. Indeed, the misdetection of increased IOP may have negative effects in the clinical management of subjects at risk of glaucomatous damage. To this end, we used the water-drinking test (WDT)20 21 as an in vivo experimental model to induce increased IOP, and the PRK as a surgical means to change corneal parameters, in a study population undergoing refractive surgery for myopia.


    Materials and Methods
 Top
 Abstract
 Materials and Methods
 Results
 Discussion
 References
 
Subjects
In this prospective study, data from 30 consecutive randomly selected eyes of 30 patients (18 men and 12 women; mean age, 33.87 ± 7.63 years; range, 22–51) who were undergoing bilateral PRK treatment for myopia were obtained. All patients were healthy and had open angles on gonioscopy and no evidence of external corneal disease or glaucoma. They were evaluated before and 6 months after the surgical procedure. In both conditions, the baseline examinations included objective refraction evaluation by an autorefractometer (model AR-600; Nidek, Aichi, Japan), mean anterior radius of corneal curvature (R) assessment (Keratron Scout; Optikon, Rome, Italy), central pachymetry readings by an ultrasonic pachymeter (Altair 606 AN; Optikon), and IOP measurements by a noncontact tonometer (model TX-10; Canon Ltd., Tokyo, Japan) according to a previous study.19 IOP measurements were performed on the same schedule between 9 and 11 AM. The mean of three consecutive readings was considered for statistical analysis, and it was rejected if the standard deviation among measurements exceeded 0.4 mm Hg.

The design and performance and experimental procedures were clearly formulated in an experimental protocol, which was approved by the institutional ethics review board and adhered to the tenets of the Declaration of Helsinki. Written, informed consent was obtained from each patient before his or her inclusion in the study and after the goals and methods of the study and the potential side effects that WDT may entail were adequately explained.

After recording of the baseline IOP, the patients were submitted to the WDT according to Nørskov21 They were instructed not to eat or drink after midnight. IOP was measured 10, 20, 30, 45, and 60 minutes after ingestion of 1 L of water within 5 minutes.

Pachymetry was performed after noncontact tonometry to prevent IOP reduction due to its corneal indentation.

Surgery was performed in all patients by one surgeon (CT) with the same technique. Both patients’ eyes were treated at the same session. An uneventful PRK was performed with an excimer laser (Technolas Keracor 217-C; Chiron, Irvine, CA), aiming at emmetropia in all cases. Before photoablation the corneal epithelium was manually removed under topical anesthesia. Postoperative topical antibiotics and artificial tears were routinely used. Topical steroids (fluorometholone acetonide 0.1%, Flarex; Alcon, Fort Worth, TX) were limited to a 7-day therapy at two doses per day.

All patients were regularly followed up in the postoperative period. At the 6-month visit, pachymetric data as well as IOPs at baseline and during WDT were obtained from the subjects, who were required to follow preoperative dietetic instructions.

To minimize the influence of different physical pre- and postoperative conditions of the patients’ corneas, all measured IOPs were recalculated according to Orssengo and Pye22 formula, briefly described elsewhere.19 This formula calculates, in mathematical terms, the corrected IOP (IOPC), dividing IOP readings by a complex correction factor that is dependent on CCT, R, applanated area, and Poisson’s ratio of the cornea.

Absolute IOP and IOPC increases (i.e., the differences between tonometric measurements at each time interval [10, 20, 30, 45, and 60 minutes] during WDT and at baseline), as well as the corresponding percentages were also calculated before and after PRK.

Statistical Analysis
A multivariate analysis of variance (MANOVA) for repeated measures with post hoc adjusted t-tests was performed to compare IOP and IOPC at baseline and during the WDT, pre- and post-PRK. The same analysis was conducted on the percentage increases. Surgery (i.e., before and after PRK) and time (i.e., at baseline and during WDT) were the within-subject factors. A significant (P < 0.05) interaction effect between these two variables was used as an indicator of differences in the shapes of the curves obtained before and after laser treatment. Percentage differences in mean tonometric readings were evaluated by adjusted t-tests, and P ≤ 0.025 was considered statistically significant to compensate for the multiple comparisons. Statistical analysis was performed on computer (SPSS, ver. 12.0.0; SPSS Science, Inc., Chicago, IL).


    Results
 Top
 Abstract
 Materials and Methods
 Results
 Discussion
 References
 
Demographic and clinical data are shown in Table 1 . Mean IOP and IOPC recorded at baseline and at various time intervals during WDT, before and after surgery, are graphically displayed in Figure 1 and presented in detail in Table 2 . After PRK, both IOP and IOPC were lower than before laser treatment. MANOVA showed a significant effect of surgery (F(1,29) = 126.227, P < 0.001, and F(1,29) = 4.954, P = 0.034 for IOP and IOPC, respectively) and time (F(5,25) = 50.437, P < 0.001, and F(5,25) = 20.080, P < 0.001 for IOP and IOPC, respectively) and a significant interaction of surgery and time (F(5,25) = 12.058, P < 0.001, and F(5,25) = 2.924, P = 0.033 for IOP and IOPC, respectively). Post hoc adjusted t-tests detected significant (P ≤ 0.025) differences in mean IOP between pre- and postoperative conditions at all time points, and in the mean IOPC at 20, 30, and 45 minutes during WDT (see Table 2 for probabilities).


View this table:
[in this window]
[in a new window]
 
TABLE 1. Demographic and Clinical Data

 


View larger version (18K):
[in this window]
[in a new window]
 
FIGURE 1. Tonometric readings serially recorded before (time 0) and at different time intervals during the WDT. Error bars, SEM.

 

View this table:
[in this window]
[in a new window]
 
TABLE 2. Measured and Corrected IOP

 
The IOP and IOPC increases from baseline during WDT expressed as an absolute value and percentage are shown in Table 3 . Postoperative absolute as well as percentages of increase in IOP and IOPC during WDT were lower than the preoperative ones, except for the IOP increases at the 60-minute time interval. MANOVA on the percentages of tonometric increase showed a significant effect of surgery (F(1,29) = 4.315, P = 0.047, and F(1,29) = 5.587, P = 0.025 for IOP and IOPC, respectively) and time (F(4,26) = 34.771, P < 0.001, and F(4,26) = 22.147, P < 0.001 for IOP and IOPC, respectively), and a significant interaction of surgery and time on IOP (F(4,26) = 4.365, P = 0.008) but not IOPC readings (F(4,26) = 1.987, P = 0.126). Post hoc adjusted t-tests did not detect significant differences in the mean percentages of IOP and IOPC increase at any time interval between pre- and postoperative conditions, except for the 30-minute time interval (see Table 3 for probabilities).


View this table:
[in this window]
[in a new window]
 
TABLE 3. Measured and Corrected IOP Increase from Baseline at Different Time Intervals during WDT

 

    Discussion
 Top
 Abstract
 Materials and Methods
 Results
 Discussion
 References
 
The relationship between CCT and IOP has been investigated in several studies.3 8 23 24 25 26 27 28 29 30 Under- and overestimate of IOP measurements may respectively occur for thinner or thicker corneas than the "normal" CCT of 520 µm proposed by Ehlers et al.,3 with an average error of 0.7 mm Hg per 10-µm deviation. Such an estimate was derived from a linear relationship between the error of Goldmann applanation tonometry, obtained experimentally by comparison with manometric readings in cannulated in vivo human eyes, and CCT as measured by optical pachymetry. However, different correction factors ranging from 0.11 to 0.71 mm Hg per 10 µm of CCT and different normal CCTs have also been proposed.1 3 4 8 25 26 27 28 29 For instance, Whitacre et al.4 based their formula on CCT data from a regression analysis of 15 eyes, whereas Doughty and Zaman1 examined the meta-analysis of 300 data sets to suggest, for healthy eyes, a correction of 1.1 mm Hg for a 50-µm difference in CCT from the "normal" value of 535 µm. Recently, Shimmyo et al.31 in an observational retrospective cross-sectional study argued that IOP adjustment could not be made with a single ratio or a linear formula, because of a nonlinear relation between Goldmann applanation tonometry readings and its errors; thus, extrapolating from their observations and the data of Ehlers et al.,3 they presented statistical approximation formulas with exponential function to calculate IOP, taking into account CCT by ultrasonic pachymetry, with 550 µm as a statistical norm (average), and corneal curvature. From a different standpoint, Orssengo and Pye22 developed a mathematical model in which the cornea was modeled as a shell, and the theoretical equations for the deformations of a shell due to internal and applanating pressures were combined to model the behavior of the cornea during applanation tonometry. In the past year, two groups have used such a purely theoretical nomogram that takes into account some corneal features, including CCT, to correct tonometric readings.2 19

Increasing clinical interest on the tonometric readings of changes in actual IOP at different CCTs has found in refractive surgery an excellent in vivo model to decrease the CCT and to evaluate the dynamic relationship between CCT and IOP measurements. Specifically, a recent paper on myopic patients who were undergoing bilateral PRK treatment showed that the effect of hypotensive drugs on IOP readings may be underestimated because of measurement errors due to the laser-induced CCT reduction.19 However, to date, no study has been undertaken to investigate the influence of different CCTs on tonometric readings in the opposite condition, (i.e., at increasing actual IOPs). To this end, in a sample of myopic patients who were undergoing excimer laser treatment, we decided to use the WDT as a mean to increase IOP, regardless of its diagnostic or prognostic value for glaucoma detection, because it is a practical test and not related to initial IOP.32 33 34 35 However, several studies have revealed that the WDT results are not reproducible because some factors such as food and fluid intake, volume of fluid to be ingested at the time, scleral rigidity, and the patient’s age, may influence the WDT.36 37 Nevertheless, in the present study we can consider our results reliable, because IOP readings were determined with the same test modalities at each time interval and compared in the same patient before and after PRK.

Although Goldmann applanation tonometry is still considered the standard method of IOP measurement, we used noncontact tonometry because it is practical, it avoids epithelial corneal alterations related to the applanation, and it needs neither topical anesthesia nor skilled physicians. In addition, this method has been demonstrated to be reproducible when the mean of three measurements is used38 and accurate when compared with the Goldmann tonometer in normal eyes.39 In this regard, a recent report has shown no significant difference between measurements even in patients undergoing PRK and LASIK, and for each degree of treated myopia, even if noncontact tonometry readings were slightly higher.40

In agreement with previous studies on decreased IOP measurements after PRK and LASIK,11 12 13 14 15 16 17 18 this study showed a statistically significant IOP decrease after excimer laser treatment at baseline as well as during WDT. However, in our patient sample, this reduction was not constant at the different time intervals during WDT, with increasing reductions toward the peak at the 20-minute time interval, and successive decreasing reductions up to the 60-minute time interval (see Fig. 1 ), which is when the effect of WDT should end, as suggested by previous studies.34 36 Similarly, when evaluating the absolute IOP increases during WDT, the mean postoperative increases were lower than before PRK, except for the values obtained when the IOP returned to baseline after 60 minutes. After individual normalization of IOP increases by comparison with baseline, the percentages of increase were still significantly different between the pre- and postoperative conditions (see MANOVA results), in particular, at the 30-minute time interval (see post hoc analysis in Table 3 ). Finally, our findings show that the corneal changes induced by PRK for myopia may underestimate IOP increase, mainly at high values.

Despite data correction for both CCT and R, the mean postoperative IOPCs remained significantly lower than preoperative ones across the time points (see MANOVA results), differing at 20, 30, and 45 minutes during WDT (P ≤ 0.025, see post hoc analysis in Table 3 ). More interesting and different from the IOP increases, the mean percentage of IOPC increase revealed a similar behavior across the time intervals in the pre- and postoperative conditions (see MANOVA results and Table 3 ). Nonetheless, the significant effect of the isolate surgery factor on these data seems to indicate the inability of the Orssengo and Pye22 nomogram to fully correct the tonometric readings when actual IOP increases (see Fig. 1 ). In this respect, the lack of statistical significance (by post hoc analysis) at the peak values, apart from the 30-minute time interval, might be accounted for by too conservative statistics (see Table 3 ).

In the present study, the purely theoretical formula of Orssengo and Pye22 was chosen because formulas derived from experimental or retrospective analysis of normal corneas may not be fully applicable to our study population, whose CCT and R were significantly modified by PRK. The inadequacy of this formula when the cornea is placed under dynamic actual IOP variation may depend, at least in part, on decreased corneal thickness and related changes in biomechanical properties14 as well as the high IOP level induced by WDT.

Physical corneal properties are largely governed by the structure of the stromal extracellular matrix, the bulk of which in human cornea comprises collagen fibrils arranged in approximately 300 to 500 parallel lamellae.41 Fibrils within a lamella are parallel to each other and to the corneal surface, but run uninterrupted from limbus to limbus at angles in relation to fibrils in adjacent lamellae.42 This collagen network, specifically the diameter of collagen fibrils, their orientation in relation to the applied force, and the collagen content of the tissue, all determine the cornea’s tensile strength.43 44 In a mathematical formula,43 the tensile strength of the tissue ({sigma}t)—that is, the stress at which the tissue breaks—is determined by

where ß is the volume fraction of the tissue that is occupied by collagen, (1 –ß) is the volume fraction occupied by the ground substance (i.e., stromal matrix elements other than fibrillar collagen, ignoring the volume of the cells), and {sigma}f and {sigma}g are the tensile strengths of the fibrils and of the ground substance, respectively, at the fibril critical length. Such a length represents the minimum fibril length required for effective tissue reinforcement, and it is related to the {sigma}f, the fibril radius and the shear stress exerted on a fibril by the ground substance.43

The higher packing density of collagen fibrils physiologically observed in the prepupillary cornea, and thus the increased collagen volume fraction with reduced fibril spacing, is necessary to maintain tissue strength,45 bearing in mind that the cornea is thinner centrally.46 47 In this way, for {sigma}f > {sigma}g in the equation, increasing the volume fraction of collagen produces a proportional increase in the mechanical strength of the tissue. Such a mechanism could help to preserve dioptric stability in the cornea by helping to maintain surface curvature in the presence of variations in tissue thickness—of course, assuming that corneal collagen fibrils are at least as long as their critical length.45

During myopic PRK, the packed collagen fibrils are photoablated in the central anterior third of the corneal stroma, and morphologic changes in subepithelial keratocytes and in the extracellular matrix occur, even in biomicroscopically clear corneas.48 This postoperative reduction of CCT, mainly related to a decreasing volume fraction of collagen, by determining {sigma}f < {sigma}g in the equation, produces a proportional decrease in the mechanical strength of the tissue. When an applanating force is applied to the cornea, the tonometric reading occurs at the balance between the external force and the sum of the actual IOP and the restoring force due to the stretched fibrils and the ground substance. Thus, we can hypothesize that the decrease in tensile strength after PRK reduces the restoring force that counteracts the applanation during tonometry. Nonetheless, this corneal behavior seems not to depend linearly on CCTs, and other currently unpredictable factors may affect this relation. Hardness or softness of the tissue may be involved and, although no significant correlation has been found between CCT and overall ocular rigidity, alterations in topical corneal rigidity–elasticity properties occurring by photoablative CCT reduction over the applanation area may influence IOP assessment.49 In addition, as ocular rigidity seems not to be significantly altered by refractive status,49 the myopic refraction of our study population should not have implications for our tonometric findings. Moreover, based on our data, this nonlinear effect may be amplified by a high IOP that increases the stress and stretch of an already altered corneal mechanical strength and further decreases the restoring force—thus explaining, at least in part, the increasing reductions of the postoperative increase in IOP during WDT in our study population (see Fig. 1 ). Similarly, an underestimate of IOP in the high-pressure range was recently detected in experimental conditions on human cadaveric eyes.50 In the future, a better comprehension of biomechanical properties of the cornea at different CCTs under different IOP levels may aid in accounting for our results and provide further factors to ameliorate the theoretical Orssengo and Pye’s nomogram.

Finally, our data show a nonlinearity of the tonometric readings at higher IOPs after corneal thinning by PRK for myopia. Nevertheless, this finding cannot be transferred to subjects with physiologically "thin" corneas. Moreover, if further studies on untreated thin corneas confirm our data, significant clinical implications in tonometric assessment of normal subjects and patients with glaucoma may be drawn—that is, eventual IOP peaks may be underestimated or even unrecognized in eyes with low CCT and high R.


    Footnotes
 
Submitted for publication October 20, 2004; revised April 8, 2005; accepted April 13, 2005.

Disclosure: C. Tamburrelli, None; A. Giudiceandrea, None; A.S. Vaiano, None; C.G. Caputo, None; F. Gullà, None; T. Salgarello, None

The publication costs of this article were defrayed in part by page charge payment. This article must therefore be marked "advertisement" in accordance with 18 U.S.C. §1734 solely to indicate this fact.

Corresponding author: Ciro Tamburrelli, Istituto di Oftalmologia, Università Cattolica S. Cuore, Lgo F. Vito 1, 00168 Rome, Italy; citam{at}tiscalinet.it.


    References
 Top
 Abstract
 Materials and Methods
 Results
 Discussion
 References
 

  1. Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol. 2000;44:367–408.[CrossRef][ISI][Medline][Order article via Infotrieve]
  2. Shih CY, Graff Zivin JS, Trokel SL, Tsai JC. Clinical significance of central corneal thickness in the management of glaucoma. Arch Ophthalmol. 2004;122:1270–1275.[Abstract/Free Full Text]
  3. Ehlers N, Bramsen T, Sperling S. Applanation tonometry and central corneal thickness. Acta Ophthalmol. 1975;53:34–43.[Medline][Order article via Infotrieve]
  4. Whitacre MM, Stein RA, Hassanein K. The effect of corneal thickness on applanation tonometry. Am J Ophthalmol. 1993;115:592–596.[ISI][Medline][Order article via Infotrieve]
  5. Morad Y, Sharon E, Hefetz L, Nemet P. Corneal thickness and curvature in normal tension glaucoma. Am J Ophthalmol. 1998;125:164–168.[CrossRef][ISI][Medline][Order article via Infotrieve]
  6. Emara BY, Tingey DP, Probst LE, Motolko MA. Central corneal thickness in low-tension glaucoma. Can J Ophthalmol. 1999;34:319–324.[ISI][Medline][Order article via Infotrieve]
  7. Copt RP, Thomas R, Mermoud A. Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma. Arch Ophthalmol. 1999;117:14–16.[Abstract/Free Full Text]
  8. Johnson M, Kass MA, Moses RA, Grodzki WJ. Increased corneal thickness simulating elevated intraocular pressure. Arch Ophthalmol. 1978;96:664–665.[Abstract]
  9. Argus WA. Ocular hypertension and central corneal thickness. Ophthalmology. 1995;102:1810–1812.[ISI][Medline][Order article via Infotrieve]
  10. Herndon LW, Choudhri SA, Cox T, Damji KF, Shields MB, Allingham RR. Central corneal thickness in normal, glaucomatous, and ocular hypertensive eyes. Arch Ophthalmol. 1997;115:1137–1141.[Abstract]
  11. Shipper I, Senn P, Thomann U, Suppiger M. Intraocular pressure after excimer laser photorefractive keratectomy for myopia. J Refract Surg. 1995;11:366–370.[ISI][Medline][Order article via Infotrieve]
  12. Chatterjee A, Shah S, Bessant DA, et al. Reduction in intraocular pressure after excimer laser photorefractive keratectomy; correlation with pretreatment myopia. J Cataract Refract Surg. 1997;104:355–359.
  13. Faucher A, Grègoire J, Blondeau P. Accuracy of Goldmann tonometry after refractive surgery. J Cataract Refract Surg. 1997;23:832–838.[ISI][Medline][Order article via Infotrieve]
  14. Mardelli PG, Piebenga LW, Whitacre MM, Siegmund KD. The effect of excimer laser photorefractive keratectomy on intraocular pressure measurements using the Goldmann applanation tonometer. Ophthalmology. 1997;104:945–948.[ISI][Medline][Order article via Infotrieve]
  15. Emara B, Probst LE, Tingey DP, et al. Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusis. J Cataract Refract Surg. 1998;24:1320–1325.[ISI][Medline][Order article via Infotrieve]
  16. Fournier AV, Podtetenev M, Lemire J, et al. Intraocular pressure change measured by Goldmann tonometry after laser in situ keratomileusis. J Cataract Refract Surg. 1998;24:905–910.[ISI][Medline][Order article via Infotrieve]
  17. Zadok D, Tran DB, Twa M, et al. Pneumotonometry versus Goldmann tonometry after laser in situ keratomileusis for myopia. J Cataract Refract Surg. 1999;25:1344–1348.[CrossRef][ISI][Medline][Order article via Infotrieve]
  18. Gartry DS. Treating myopia with excimer laser: the present position. BMJ. 1995;310:979–985.[Abstract/Free Full Text]
  19. Tamburrelli C, Vaiano AS, Salgarello T, Caputo CG, Scullica L. Tonometric changes of latanoprost-induced intraocular pressure reduction after photorefractive keratectomy. Invest Ophthalmol Vis Sci. 2004;45:846–850.[Abstract/Free Full Text]
  20. Leydhecker W. The water-drinking test. Br J Ophthalmol. 1950;34:457–479.[Free Full Text]
  21. Nørskov K. The water provocative test. Acta Ophthalmol. 1967;45:57–67.[Medline][Order article via Infotrieve]
  22. Orssengo GJ, Pye DC. Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo. Bull Math Biol. 1999;61:551–572.[CrossRef][ISI][Medline][Order article via Infotrieve]
  23. Ehlers N. On corneal thickness and intraocular pressure. II. A clinical study on the thickness of the corneal stroma in glaucomatous eyes. Acta Ophthalmol (Copenh). 1970;48:1107–1112.
  24. Whitacre MM, Stein R. Sources of error with use of Goldmann-type tonometers. Surv Ophthalmol. 1993;38:1–30.[CrossRef][Medline][Order article via Infotrieve]
  25. Wolfs RC, Klaver CC, Vingerling JR, Grobbee DE, Hofman A, de Jong PT. Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study. Am J Ophthalmol. 1997;123:767–772.[ISI][Medline][Order article via Infotrieve]
  26. Bron AM, Creuzot-Garcher C, Goudeau-Boutillon S, d’Athis P. Falsely elevated intraocular pressure due to increased central corneal thickness. Graefes Arch Clin Exp Ophthalmol. 1999;237:220–224.[CrossRef][ISI][Medline][Order article via Infotrieve]
  27. Shah S, Spedding C, Bhojwani R, Kwartz J, Henson D, McLeod D. Assessment of the diurnal variation in central corneal thickness and intraocular pressure for patients with suspected glaucoma. Ophthalmology. 2000;107:1191–1193.[CrossRef][ISI][Medline][Order article via Infotrieve]
  28. Mills RP. If intraocular pressure measurement is only an estimate-then what?. Ophthalmology. 2000;107:1807–1808.[CrossRef][ISI][Medline][Order article via Infotrieve]
  29. Singh RP, Goldberg I, Graham SL, Sharma A, Mohsin M. Central corneal thickness, tonometry, and ocular dimensions in glaucoma and ocular hypertension. J Glaucoma. 2001;10:206–210.[CrossRef][ISI][Medline][Order article via Infotrieve]
  30. Lleò A, Marcos A, Calatayud M, Alonso L, Rahhal SM, Sanchis-Gimeno JA. The relationship between central corneal thickness and Goldmann applanation tonometry. Clin Exp Optom. 2003;86:104–108.[Medline][Order article via Infotrieve]
  31. Shimmyo M, Ross AJ, Moy A, Mostafavi R. Intraocular pressure, Goldmann applanation tension, corneal thickness, and corneal curvature in Caucasians, Asians, Hispanics, and African Americans. Am J Ophthalmol. 2003;136:603–613.[CrossRef][ISI][Medline][Order article via Infotrieve]
  32. Rasmissa KE, Jorgensen HA. Diagnostic value of the water drinking test in early detection of simple glaucoma. Acta Ophthalmol. 1976;54:160–166.[Medline][Order article via Infotrieve]
  33. Mehra KS. Water drinking provocative test. Ann Ophthalmol. 1979;11:223–224.[Medline][Order article via Infotrieve]
  34. Diestelhorst M, Krieglstein GK. The effect of the water-drinking test on aqueous humor dynamics in healthy volunteers. Graefes Arch Clin Exp Ophthalmol. 1994;232:145–147.[Medline][Order article via Infotrieve]
  35. Brubaker RF. Targeting outflow facility in glaucoma management. Surv Ophthalmol. 2003;48(suppl. 1)S17–S20.
  36. Spaeth GL. The water drinking test: indications that factors other than osmotic considerations are involved. Arch Ophthalmol. 1967;77:50–58.[Medline][Order article via Infotrieve]
  37. Roth JA. Inadequate diagnostic value of the water-drinking test. Br J Ophthalmol. 1974;58:55–61.[Free Full Text]
  38. Myers KJ, Scott CA. The non-contact ("air-puff") tonometer: variability and corneal staining. Am J Optom Physiol Opt. 1975;52:36–46.[ISI][Medline][Order article via Infotrieve]
  39. Shields MB. The non-contact tonometer: its value and limitations. Surv Ophthalmol. 1980;24:211–219.[CrossRef][ISI][Medline][Order article via Infotrieve]
  40. Montés-Micó R, Charman WN. Intraocular pressure after excimer laser myopic refractive surgery. Ophthalmic Physiol Opt. 2001;21:228–235.[CrossRef][ISI][Medline][Order article via Infotrieve]
  41. Maurice DM. The structure and transparency of the corneal stroma. J Physiol. 1957;136:263–286.[Free Full Text]
  42. Maurice DM. The cornea and sclera. Davson H eds. The Eye. Vegetative Physiology and Biochemistry. 1984;1b:1–158. Academic Press Orlando, FL.
  43. Hukins DWL, Aspden RM. Composition and properties of connective tissues. Trends Biochem Sci. 1985;10:260–264.[CrossRef]
  44. Jeronimidis G, Vincent JFV. Composite materials. Hukins DWL eds. Connective Tissue Matrix. 1984;187–210. Macmillan London.
  45. Boote C, Dennis S, Newton RH, Puri H, Meek KM. Collagen fibrils appear more closely packed in the prepupillary cornea: optical and biomechanical implications. Invest Ophthalmol Vis Sci. 2003;44:2941–2948.[Abstract/Free Full Text]
  46. Martola EL, Baum JL. Central and peripheral corneal thickness. Arch Ophthalmol. 1968;79:28–30.[ISI][Medline][Order article via Infotrieve]
  47. Edmund C. Determination of the corneal thickness profile by optical pachometry. Acta Ophthalmol. 1987;65:147–152.[Medline][Order article via Infotrieve]
  48. Moilanen JAO, Vesaluoma MH, Muller LJ, Tervo TMT. Long-term corneal morphology after PRK by in vivo confocal microscopy. Invest Ophthalmol Vis Sci. 2003;44:1064–1069.[Abstract/Free Full Text]
  49. Pallikaris IG, Kymionis GD, Ginis HS, Kounis GA, Tsilimbaris MK. Ocular rigidity in living human eyes. Invest Ophthalmol Vis Sci. 2005;45:409–414.
  50. Kniestedt C, Nee M, Stamper RL. Dynamic contour tonometry: a comparative study on human cadaver eyes. Arch Ophthalmol. 2004;122:1287–1293.[Abstract/Free Full Text]




This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tamburrelli, C.
Right arrow Articles by Salgarello, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tamburrelli, C.
Right arrow Articles by Salgarello, T.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS