|
|
||||||||
1From the Departments of Ophthalmology and Visual Sciences and 4Cell Biology and Physiology, the 2Barnes Retina Institute, and the 3Division of Comparative Medicine, Washington University, St. Louis, Missouri.
| Abstract |
|---|
|
|
|---|
METHODS. Young albino rabbits were anesthetized, intubated, and exposed to normoxic, hypoxic, or hyperoxic conditions. The hemoglobin saturation of the blood was monitored with a pulse oximeter, and arterial oxygen levels were measured with a blood gas analyzer. A fiberoptic optical oxygen sensor (optode) was used to determine oxygen levels in different regions of the eye. Oxygen flux across the posterior of the lens was calculated from the measured oxygen gradients in the vitreous chamber.
RESULTS. Oxygen levels in the ocular fluids changed markedly when rabbits breathed air made hypoxic or hyperoxic. Oxygen levels were highest near the retinal vasculature, the iris vasculature, and the inner surface of the central cornea. Compared with nearby regions, oxygen levels were decreased in the aqueous humor closest to the pars plicata of the ciliary body and near the anterior chamber angle. Oxygen levels were generally lower closer to the lens. From the oxygen gradients in the vitreous body, oxygen consumption by the posterior half of the lens was calculated to be 0.2 to 0.4 µL/h under normoxic conditions. Oxygen consumption by the posterior of the lens increased in proportion to the amount of oxygen supplied.
CONCLUSIONS. Intraocular oxygen is mostly derived from the retinal and iris vasculature and by diffusion across the cornea. Freshly secreted aqueous humor and the aqueous humor in the anterior chamber angle are relatively depleted of oxygen. The marked increase in oxygen consumption that occurs when the lens is exposed to increased oxygen is likely to result in the production of higher levels of reactive oxygen species and may provide a link between elevated oxygen levels and the risk of nuclear cataracts.
While maintaining adequate oxygen supply is essential for the retina, the opposite may be true of the lens. The oxygen level measured in the vitreous body of normal rabbit, feline, rat, and human eyes is low, between 8 and 20 mm Hg (
1%3% O2).8 9 10 11 12 13 14 15 Results in reported studies have led to the hypothesis that increased exposure of the lens to oxygen may contribute to nuclear cataract formation.8 12 16 17 18 19 In accord with this hypothesis, vitrectomy leads to rapid-onset nuclear cataracts in humans and is associated with a substantial, long-term increase in oxygen levels near the lens. 8 12
In the present studies, we used an optical oxygen sensor (optode) to measure oxygen levels in the anterior, posterior, and vitreous chambers of rabbits breathing normal, higher or lower partial pressures of oxygen. These data show that intraocular oxygen is derived from several sources. Changes in the level of inspired oxygen leads to changes in the oxygen levels around the lens, which alters its rate of oxidative metabolism.
| Methods |
|---|
|
|
|---|
Anesthesia and Oxygen Delivery
To measure the partial pressure of oxygen in rabbit eyes under conditions that were similar to resting conditions, we first determined the hemoglobin saturation of the blood and the oxygen level in the center of the vitreous body of rabbits maintained in room air (
21% O2), hypoxic conditions (11% O2), or hyperoxic conditions (60% O2). Rabbits were kept in plastic enclosures that were gassed with room air or room air supplemented with the appropriate amount of nitrogen, or oxygen using an oxygen controller (Pro-Ox 110; Biospherix, Redfield, NY). After 2 hours, hemoglobin saturation was recorded and the animals were anesthetized, while still in the modified gas mixture, by intraperitoneal injection of ketamine and xylazine (5 and 35 mg/kg body weight, respectively). As soon as an animal was anesthetized, it was moved to room air, the fiberoptic optode was rapidly inserted through a small puncture wound made in the eye with a 23-gauge needle and positioned in the midvitreous cavity. Because these measurements were made within minutes of anesthesia, the oxygen levels that were recorded approximated the resting oxygen levels in the vitreous body under nonanesthetized conditions. In room air, over a period of 30 minutes after the initial measurements, oxygen levels slowly decreased when animals had been exposed to hyperoxic conditions or increased when animals had been exposed to hypoxic conditions (data not shown).
For studies in which rabbits were maintained for longer periods under defined oxygen conditions, animals were first anesthetized with ketamine-xylazine, and then isoflurane was administered through a mask for 3 to 5 minutes before intubation. A 3-0 cuffed endotracheal tube was inserted and connected to an anesthesia machine (Narkomed 2A; North American Dräger, Louisville, KY). Anesthesia was then maintained with 2% isoflurane. During the oxygen measurements, hemoglobin saturation (SaO2), heart rates, respiratory rates, CO2 inspiration and expiration, and body temperature were monitored (model 1500; Nellcor, Pleasanton, CA). All animals were initially maintained in conditions that resembled normal breathing. They received 20% oxygen, and the rate of respiration was adjusted to keep the SaO2 at the normal level of
97%. The partial pressure of oxygen in different regions of the eye was then measured.
Two types of experiments were performed. In the first series, animals were equilibrated to 20% oxygen, and oxygen levels in the in several regions of the eye were measured. Then, while the same rate of respiration was maintained, the level of inspired oxygen was decreased or increased to 13% or 60%, respectively, for 1 hour, and a second set of measurements was made. In animals exposed to hyperoxia, the hemoglobin rapidly saturated. Under hypoxic conditions, the SaO2 decreased to approximately 75%, which was the level measured in nonanesthetized rabbits maintained in 11% O2. After measurements were made, the animals were killed by overdose of pentobarbital (100 mg/kg).
Oxygen Measurements in Rabbit Eyes
An optical oxygen sensor and probe (Oxylab pO2 optode; Oxford Optronix, Oxford, UK) was used as previously described, to measure oxygen levels in several locations within the eye.8 17 The diameter of the probe is 200 to 220 µm (
25 gauge). Although this probe does not have the same spatial resolution as the microelectrodes used in some studies,5 20 it has the advantage that it does not consume oxygen and is most sensitive at low oxygen levels. To measure oxygen partial pressures in rabbits under circumstances that were as close as possible to physiological, we avoided the use of drugs that might affect ocular blood flow. The pupils were not dilated. To avoid damaging the rabbit lens, which occupies a larger proportion of the globe than in the human eye, we used two sclerotomies. The first was 2.5 mm and the second 6.5 mm posterior to the corneal limbus. These locations are labeled A and B, respectively, in Figure 1 . The first sclerotomy was made with the tip of a 23-gauge needle at position A, the probe was inserted through the sclerotomy and gently moved into the posterior and anterior chambers. Because of the flexibility of the scleral wall in rabbits, the sclera and cortical vitreous sealed around the shaft of the probe, and there was no leakage of fluid or obvious loss of intraocular pressure. Measurements were first taken in the posterior chamber close to the pars plana of the ciliary body (Fig. 1 ; PC1), in the posterior chamber close to the pars plicata of the ciliary body (PC2), in the posterior chamber under the middle of the iris (PC3,) and in the posterior chamber at the edge of the pupil (PC4). The blue light from the tip of the optode was visible under the iris of the albino animals, assisting the positioning of the probe at locations PC3 and PC4. The probe was then positioned in the anterior chamber at the surface of the lens (AC lens), in the center of the anterior chamber (AC center), at the posterior surface of the cornea (AC cornea), and, finally at the anterior chamber angle (AC angle). The probe was then withdrawn to the posterior chamber, and a measurement was made at the equator of the lens (A LEQ). Oxygen measurements were recorded for 2 to 4 minutes at each position. To minimize the distortion of aqueous humor flow, the probe was moved from point to point, slowly and gently, under a surgical microscope. Oxygen readings were repeatable in the same animal by returning to the same point, signifying that the flow of aqueous humor and oxygen metabolism were not disturbed by the measurement procedure. When the oxygen measurements were completed in the anterior of the eye, the probe was removed. The wound site was sealed by a small plug of cortical vitreous, and no aqueous humor leaked out of the eye. A second, posterior sclerotomy was made 6.5 mm from the limbus and the probe was inserted. The partial pressure of oxygen was measured, in sequence, at the central posterior surface of lens (VC lens), in the center of the vitreous chamber (VC center), in the vitreous body just anterior to the central retina (VC retina), and near the equatorial retina on the opposite side of the eye (VC eq). The probe was then withdrawn to measure the oxygen level just posterior to the lens equator (B LEQ). Because bright light can alter the values obtained with the optode, only normal laboratory illumination was used during measurements. We confirmed that this amount of light did not alter the readings by checking oxygen levels with the lights on or off. In the low light that reached the interior of the eye, the blue excitation light at the tip of the probe permitted accurate positioning for each of the oxygen measurements. The mean and SEM of PO2 are reported for each location. IOP decreased by an average of 11% after the second sclerotomy and was at all times within the normal range for rabbits.
|
|
|
Estimation of Oxygen Consumption by the Posterior of the Lens
Oxygen flux across the posterior of the lens was estimated at different concentrations of inspired oxygen from the dimensions of the posterior of whole rabbit eyes that had been sectioned parallel to the optical axis), the oxygen gradients in the vitreous body and the diffusion constant of oxygen in water. These values were used to obtain the flux of oxygen (J) using equation (1) :
![]() | (1) |
Measurement of Oxygen Level Gradients in the Vitreous Body
As described earlier, the oxygen partial pressures measured in several locations at the surface of the retina, in the middle of the vitreous body, and near the posterior surface of the lens at four different levels of inspired oxygen (Tables 2 3 and 4) . Near the retinal surface, the oxygen level varied greatly, depending on the proximity to the retinal vascular "streak" that lies in the horizontal plane of the globe (see Fig. 6 ). We accounted for the unequal distribution of oxygen on the retinal surface in two ways; In the first case, we averaged the oxygen level at all the points that were measured on the retina and used this mean value for the high end of the oxygen gradient. The average value at the posterior of the lens was used for the lower end of the gradient. Because it was not possible to obtain measures of PO2 along the 135° and 225° meridians at the surface of the retina, we used the values from the 45° and 315° meridians twice. We believe that averaging the PO2 at the surface of the retina was warranted, because, as shown in Figure 6 , the variation in retinal oxygen values diminishes greatly by the time the oxygen diffuses into the midvitreous, effectively "averaging" variations in retinal PO2. In a second approach, we calculated the oxygen gradient from the PO2 in the middle of the vitreous and at the posterior surface of the lens.
|
|
|
Surface Area of the Posterior of the Lens and the Inner Retina
The rabbit lens is ellipsoid. Therefore, we determined its perimeter (P) using equation (2) :
![]() | (2) |
Calculations
The PO2 gradients and the average distance from the lens to the retina were entered into equation (1) and corrected for differences in the surface areas of the lens and retina by using a spreadsheet (Excel; Microsoft, Redmond, WA), yielding values for J at different levels of inspired oxygen. Arterial blood saturation and mean oxygen levels at the surface of the retina were directly proportional to inspired oxygen (R2 = 0.98 for both). For convenience, oxygen flux was plotted against inspired oxygen.
| Results |
|---|
|
|
|---|
To obtain measurements of intraocular oxygen levels under baseline and hyperoxic conditions, SaO2 was first stabilized at approximately 97% by regulating the respiratory rate of anesthetized rabbits breathing 20% oxygen. Baseline intraocular oxygen measurements were made and then the inspired gas was increased to 60% oxygen at the same rate of respiration. The SaO2 rapidly saturated and oxygen levels in the intraocular fluids increased. By 60 minutes after increasing the level of oxygen, oxygen levels in the intraocular fluids stabilized and a second set of measurements was made. To obtain intraocular oxygen levels under baseline and hypoxic conditions, oxygen measurements were again made at 97% SaO2 and then the inspired gas was lowered to 12% to 14% oxygen to maintain the SaO2 between 75% and 80%the SaO2 found in rabbits maintained in an atmosphere of 11% oxygen. Oxygen levels in the intraocular fluids were measured 60 minutes after lowering the inspired oxygen.
Oxygen Distribution in the Eyes of Rabbits Maintained at Normal SaO2
Figure 2 shows the mean partial pressure of oxygen in the intraocular fluids of rabbits maintained at SaO2 of 97%. Inspection of the oxygen distribution in these eyes suggests that oxygen enters the eye by several routes. Oxygen levels were high at all locations around the periphery of the eye and decreased toward the lens. Therefore, oxygen is provided to the intraocular fluids by the vascular supply to the retina and iris and from the air by diffusion through the cornea. The standing oxygen gradients observed in the anterior chamber and the vitreous body confirmed the expectation that the rabbit lens is constantly consuming oxygen.
|
A gradient of increasing oxygen level was found in the anterior chamber from the anterior surface of the lens to the central corneal endothelium, suggesting that much of the oxygen in the middle of the anterior chamber comes from diffusion across the cornea. Compared with the levels found beneath the central cornea, the levels of oxygen were unexpectedly low near the anterior chamber angle. This observation suggests that oxygen transmission may be lower or consumption may be higher in this region. To be sure of these levels, measurements were made several times in each rabbit. Care was taken that the eye lids did not cover or approach the peripheral cornea during equilibration or when the measurements were being made, assuring that coverage by the eyelid did not cause a decrease in oxygen diffusion near the angle.
The PO2 in the aqueous humor near the lens equator was less than half of that near the pars plana and pars plicata of the ciliary epithelium and much lower than the levels beneath the iris. Therefore, the cells in the germinative zone of the lens, near the lens equator, appear to be exposed to significantly lower levels of oxygen than the epithelial cells located in more anterior regions of the lens.
Oxygen levels in the vitreous chamber were highest near the posterior retina and declined near the peripheral retina. In these initial measurements, no effort was made to account for the differences in oxygen distribution that occur due to the nonuniform distribution of vessels in the rabbit retina. A more detailed map of oxygen distribution at the surface of the retina is shown in studies described in the following section. A gradient of decreasing oxygen level was present from the surface of the retina to the posterior of the lens.
Oxygen Distribution in the Eyes of Rabbits Breathing Increased or Decreased Oxygen
Breathing 60% oxygen for 60 minutes caused rapid saturation of blood hemoglobin and an increase in the oxygen levels inside the eye (Fig. 3) . The oxygen optode used in these studies was most sensitive to low levels of oxygen and could not reliably measure oxygen levels over 100 mm Hg. The oxygen levels in the eyes of rabbits exposed to 60% oxygen were, in most cases, greater than 100 mm Hg, precluding accurate quantification. Only around the lens (and away from the iris), the sites at which oxygen levels were lowest when animals breathed 20% oxygen, was quantification possible. At these locations, changing from breathing 20% to 60% oxygen caused the PO2 to increase by approximately 5 to more than 12 times the level in animals breathing 20% oxygen (compare Figs. 2 and 3 ).
|
|
|
Much of the rabbit retina is avascular. A narrow band of vessels arises from the optic disc, supplying a horizontal stripe of retinal tissue (Fig 6A) . From the initial measurements and knowledge of the vascular anatomy of the rabbit retina, it was expected that there would be large variations in PO2 over different regions of the retina, depending the proximity of the optode to the vasculature. We felt that accurate estimates of the oxygen gradients across the vitreous body might require detailed knowledge of the PO2 at the surface of the retina. Therefore, maps were made of oxygen level at many locations near the retinal surface (Fig. 6A) . Oxygen measurements were also obtained at five locations within the vitreous body, midway between the retina and the lens (Fig. 6B) . These measurements provided useful information about the PO2 at greater distance from the retina, where local fluctuations in oxygen tension at the retinal surface would be damped by diffusion. PO2 was also measured at four locations at the posterior surface of the lens (Fig. 6B) . The pupils of the rabbit eyes were also dilated for better visualization of the location of the probe in the vitreous chamber and at the retinal surface. The level of inspired oxygen was varied from 12% to 14% and 40%. The PO2 in different regions of the posterior of the eye obtained in animals breathing 20% oxygen are shown in Figs. 6C and 6D . The SaO2 and arterial PO2 of rabbits breathing different levels of oxygen are in Table 1 . PO2 at the retinal surface, midvitreous, and posterior of the lens at each oxygen level are in Tables 2 3 and 4 .
When the average PO2 at the vitreal surface of the retina was used to calculate the oxygen level gradient, the calculated mean flux of oxygen across the posterior surface of the lens was 0.34 µL/h in normoxic conditions (see the Methods section). When the midvitreous-to-lens oxygen level gradient was used for this calculation, oxygen consumption by the posterior half of the lens was 0.21 µL/h. Despite the differences in these values, both methods for estimating the oxygen flux across the posterior of the lens demonstrated that oxygen consumption increased with an increase in the amount of oxygen supplied (Figs. 7) . Although the oxygen consumption calculated from the retina-to-lens gradient was best fit with an exponential (Fig. 7A) , a linear fit to the data was nearly as good (R2 = 0.76 vs. 0.71). Oxygen consumption calculated from the vitreous-to-lens gradient was best described by a linear relationship (Fig. 7B) . The slopes of the lines describing the fluxes of oxygen across the posterior of the lens at different oxygen levels were greater than 1, indicating that oxygen consumption increased more rapidly as oxygen levels increased.
|
| Discussion |
|---|
|
|
|---|
Because the ciliary body is well vascularized, we were surprised to find that oxygen levels were low in the aqueous humor near the pars plicata, the site of origin of the aqueous humor. Although the ciliary epithelium actively transports components of the aqueous humor, our measurements show that little oxygen enters the eye by this path. It seems likely that the abundant mitochondria in the ciliary folds use oxidative metabolism to power transepithelial transport,22 thereby depleting oxygen from the secreted aqueous humor. As the aqueous humor flows beneath the iris, oxygen levels increase, presumably due to diffusion from the iris vasculature.
Oxygen levels were substantially lower in the aqueous humor near the anterior chamber angle than beneath the central cornea. Hypoxia led to a decrease in the oxygen levels in the aqueous humor of the angle, but not in the aqueous humor adjacent to the central cornea. This was surprising, because the anatomy of the cornea in its central and peripheral regions is similar. These observations confirm that oxygen reaches the aqueous humor beneath the central cornea by diffusion from the surrounding air, as suggested previously.21 23 By contrast, the oxygen in the aqueous humor in the angle appears to be derived primarily from the vasculature of the iris, ciliary body, and/or the limbus and not by diffusion across the peripheral cornea. Helbig et al.24 found levels of oxygen near the human angle that were higher than in the present study (45 mm Hg vs. 27 mm Hg). However, they did not compare oxygen levels near the angle to those beneath the central cornea. Therefore, it is not clear whether the relative difference in oxygen distribution between these regions, as detected in rabbits, is also present in humans. The lower oxygen levels near the anterior chamber angle could be relevant to the biology of the cells of the trabecular meshwork and the aqueous humor outflow pathway.
Intraocular Oxygen Levels in Hyperoxia and Hypoxia
Breathing 60% oxygen caused the level of oxygen in most parts of the eye to exceed 100 mm Hg within 1 hour. PO2 at several locations around the lens remained measurable, however. In these locations, oxygen levels increased between 5- and 12-fold. It seems reasonable to ask how an approximate threefold increase in the level of inspired oxygen could lead to disproportionately large increases in PO2 near the surface of the lens. The answer to this question is likely to be related to the unusual way that the rabbit retina deals with exposure to increased oxygen. Under normal oxygen conditions in all species studied, oxygen consumption by the retina leads to a relatively low PO2 in the vitreous near the surface of the retina. In most of these animals (cat, rat, guinea pig, and monkey), increases in blood oxygen levels do not significantly alter preretinal (vitreous) oxygen levels.10 11 15 25 26 27 However, in rabbits, small increases in inspired oxygen above normoxia lead to large relative increases in oxygen levels at the interface of the retina and vitreous.5 20 Because the level of oxygen around the posterior of the lens is largely determined by the diffusion of oxygen from the preretinal vitreous and the consumption of oxygen by the lens, an increase in oxygen at the retinal surface results in an increase in oxygen tension around the posterior of the lens. Therefore, modest increases in inspired oxygen (
3-fold) result in large relative increases in oxygen at the posterior of the lens (5- to 12-fold).
At all levels of inspired oxygen, the level of oxygen near the lens equator was substantially lower than in more anterior regions of the posterior chamber. This means that the germinative zone of the lens epithelium is likely to be exposed to lower levels of oxygen than the central regions of the lens epithelium. We have observed that the rate of proliferation of germinative zone epithelial cells is suppressed by hypoxia in vivo (Shui, et al., manuscript in preparation). Therefore, the normally low level of oxygen near the lens equator may be essential in controlling lens growth.
Consumption of Oxygen by the Lens
The level of oxygen in the intraocular fluids was always lower near the lens than near more peripheral tissues. We used the measured oxygen gradients in the vitreous body to estimate the rate of oxygen consumption by the posterior half of the lens in vivo. We did not attempt to calculate oxygen consumption by the anterior of the lens, because the geometry of the posterior and anterior chambers is complex, and estimates would be complicated by the flow of aqueous humor. Published rates of oxygen consumption by the rabbit lens in vitro vary greatly, ranging between 6.8 to 260 µL O2/g wet weight/h (for review, see Refs. 28 ,29 ). This variability may be due to the relatively low rates of oxygen consumption by lenses, coupled with the insensitivity of some of the methods used to make these measurements and the different levels of ambient oxygen present during the measurement.28 It is also possible that some of this variability was due to damage to the lens that occurred during isolation and differences in the chemical composition between the test solutions and the intraocular fluids. These potential sources of error are avoided by estimating the consumption of oxygen by the lens in vivo.
In normoxic conditions, the flux of oxygen across the posterior half of the lens, calculated using two methods of estimating the oxygen gradients, averaged 0.21 and 0.34 µL per hour. These seem to be reasonable levels, given that a whole adult rabbit lens consumes
1.8 µL O2/h when measured in a well-stirred respirometer in 5% O2.28 Compared with the levels of oxygen normally found around the lens in vivo, 5% oxygen (
38 mm Hg) is actually quite high. Based on our observation that the rate of oxygen consumption increases with increasing oxygen exposure, measuring the oxygen consumption of the lens in 5% oxygen could overestimate the amount of oxygen that is normally consumed by the lens in situ. In addition, we only estimated oxygen consumption by the posterior of the lens. The epithelial cells in the anterior of the lens, because of their higher concentration of mitochondria, would be expected to consume more oxygen than would the posterior fiber cells.30 31
Over most of the range of oxygen levels tested, the rate of oxygen consumption by the posterior of the rabbit lens increased in proportion to the level of inspired oxygen. This behavior is different from that in most tissues. For example, the rabbit retina consumes the same amount of oxygen under normoxic and hyperoxic conditions.5 20 The unusual response of the lens to increased oxygen supply may be related to the fact that lens cells are normally hypoxic, whereas most vascularized tissues are usually provided with ample oxygen. Another normally avascular tissue, cartilage from the epiphyseal region of long bones, shows a proportional increase in oxygen consumption at low oxygen levels, but a hyperbolic (saturating) relationship between oxygen supplied and oxygen consumed at higher oxygen levels.32 33 In the present studies, the oxygen flux across the posterior of the lens increased linearly up to the highest levels tested. We may have been able to saturate the response of the lens to oxygen, had we been able to reach higher oxygen levels. However, the range of the optodes used in our study precluded testing higher oxygen levels. Alternatively, the hyperbolic response of chondrocytes to increasing oxygen may reflect their need to reduce the rate of oxidative metabolism at high oxygen levels, since some chondrocytes will normally be close to the blood supply and exposed to higher levels of oxygen, while cells in the center of the tissue might be quite hypoxic. Fiber cells from adult lenses, due to their normally hypoxic environment and distance from the vascular supply, may not be able to limit their oxygen consumption in the face of higher levels of oxygen.
It is well known that mitochondrial oxidative metabolism produces reactive oxygen species (ROS), including superoxide anion and hydrogen peroxide. The production of ROS by isolated mitochondria increases as a linear function of oxygen tension.34 35 Previous investigators have suggested that ROS contribute to cataract formation.12 36 37 38 39 40 Several studies have suggested that exposure of the lens to elevated intraocular oxygen is a risk factor for nuclear cataracts.8 12 16 17 18 19 The highest levels of intraocular oxygen measured in the present study were similar to those that are typically reached during vitrectomy8 ; oxygen levels are likely to be even higher in patients treated with hyperbaric oxygen therapy. Both treatments are associated with the formation of nuclear cataracts.8 18 19 Therefore, increased production of ROS may explain the association between exposure of the lens to higher levels of oxygen and increased risk of cataract formation.
Our results show that the oxygen levels around the lens can be readily manipulated by altering the level of inspired oxygen. As described earlier, increasing the exposure of the lens to oxygen appears to increase the risk of cataract. Therefore, lowering the levels of oxygen around the lens might protect against nuclear cataract, perhaps by reducing the production of ROS. Based on the data obtained in this study, it should be possible to test this hypothesis in experimental animals by determining whether nuclear cataract formation is decreased in animals breathing lower levels of inspired oxygen.
| Acknowledgements |
|---|
| Footnotes |
|---|
Submitted for publication November 17, 2005; revised December 9, 2005; accepted February 10, 2006.
Disclosure: Y.-B. Shui, None; J.-J. Fu, None; C. Garcia, None; L. K. Dattilo, None; R. Rajagopal, None; S. McMillan, None; G. Mak, None; N.M. Holekamp, None; A. Lewis, None; D.C. Beebe, None
The publication costs of this article were defrayed in part by page charge payment. This article must therefore be marked "advertisement" in accordance with 18 U.S.C.
1734 solely to indicate this fact.
Corresponding author: David C. Beebe, Department of Ophthalmology and Visual Sciences, Washington University, St. Louis, MO 63110; beebe{at}wustl.edu.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
B. J. Ortwerth, J. Bhattacharyya, and E. Shipova Tryptophan Metabolites from Young Human Lenses and the Photooxidation of Ascorbic Acid by UVA Light Invest. Ophthalmol. Vis. Sci., July 1, 2009; 50(7): 3311 - 3319. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Akoyev, S. Das, S. Jena, L. Grauer, and D. J. Takemoto Hypoxia-Regulated Activity of PKC{epsilon} in the Lens Invest. Ophthalmol. Vis. Sci., March 1, 2009; 50(3): 1271 - 1282. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y.-B. Shui, J. M. Arbeit, R. S. Johnson, and D. C. Beebe HIF-1: An Age-Dependent Regulator of Lens Cell Proliferation Invest. Ophthalmol. Vis. Sci., November 1, 2008; 49(11): 4961 - 4970. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Chen, Y.-q. Doughman, S. Gu, A. Jarrell, S.-i. Aota, A. Cvekl, M. Watanabe, S. L. Dunwoodie, R. S. Johnson, V. van Heyningen, et al. Cited2 is required for the proper formation of the hyaloid vasculature and for lens morphogenesis Development, September 1, 2008; 135(17): 2939 - 2948. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y.-B. Shui and D. C. Beebe Age-Dependent Control of Lens Growth by Hypoxia Invest. Ophthalmol. Vis. Sci., March 1, 2008; 49(3): 1023 - 1029. [Abstract] [Full Text] [PDF] |
||||
![]() |
Q. Cheng, T. Nguyen, H. Song, and J. Bonanno Hypoxia Protects Human Corneal Endothelium from Tertiary Butyl Hydroperoxide and Paraquat-Induced Cell Death In Vitro Experimental Biology and Medicine, March 1, 2007; 232(3): 445 - 453. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |