|
|
||||||||
1From the Departamento de Fisiologia, Universidade Federal do Pará, Brazil; and 2Núcleo de Medicina Tropical, Universidade Federal do Pará, Brazil.
| Abstract |
|---|
|
|
|---|
METHODS. The stimuli consisted of horizontal luminance gratings. In the VEP experiments, 0.4, 0.8, 2, 4, 8, and 10 cpd of spatial frequency were used, at 1 Hz square-wave contrast-reversal mode. Eight to 10 Michelson contrasts were used at each spatial frequency. Contrast thresholds were estimated from extrapolation of contrast response functions. Psychophysical sensitivities were obtained with spatial gratings of 0.4, 0.8, 1, 2, 4, 6, 8, and 10 cpd and presented at 1 Hz square-wave contrast-reversal or stationary mode (dynamic and static presentation, respectively). CSF tuning was estimated by calculating the ratio between peak sensitivity and the sensitivity at 0.4 cpd.
RESULTS. In all subjects tested (n = 6), VEP contrast-response functions showed nonlinearitiesnamely, amplitude saturation and double-slope amplitude functions that occurred at low and medium-to-high spatial frequencies, respectively. Mean electrophysiological and psychophysical CSFs peaked at 2 cpd. CSF tuning for electrophysiology and dynamic and static psychophysics were, respectively, 1.08, 1.11, and 1.31. Correlation coefficients (r2) between electrophysiological CSF and dynamic or static psychophysical CSF were, respectively, 0.81 and 0.45.
CONCLUSIONS. Electrophysiological and psychophysical CSFs correlated more positively when temporal presentation was similar. Spatial frequencies higher than 2 cpd showed that at least two visual pathways sum their activities at high contrasts. At low contrast levels, the results suggest that the transient VEP is dominated by the magnocellular (M) pathway.
In this study, we assessed the similarity of the spatial luminance CSF obtained with transient VEP, when compared with that obtained psychophysically with similar stimuli. We also analyzed whether transient VEP amplitudes can be related to visual parallel pathway sensitivities. The transient VEP can be used as an objective tool to study spatial luminance CSF. There was good agreement between the electrophysiological and psychophysical measurements obtained with the same temporal frequency. Our results suggest that the M pathway is the main source of the VEP amplitude, at least at low-luminance contrasts. Some of these results have been presented in abstract form (Souza et al. IOVS 2006;47:ARVO E-Abstract 5379).
| Methods |
|---|
|
|
|---|
Visual Stimulation
We used visual-stimulus software (Psycho ver. 2.6; Cambridge Research Systems, Rochester, UK) to drive a graphic card (VSG 2/3; Cambridge Research Systems). The stimuli were presented on a 20-in. color monitor (FlexScan T662, Eizo, Ishikawa, Japan) with a frame rate of 100 Hz and a spatial resolution of 800 x 600 pixels. Gamma correction was performed with a photometer (OptiCAL OP200E; Cambridge Research Systems).
Visual stimuli were similar throughout the electrophysiological and psychophysical tests, consisting of achromatic horizontal sinusoidal gratings, with CIE1976 chromaticity (u', v') = (0.215, 0.480) and 40 cd/m2 of mean luminance and were presented in a circular patch (5° of visual field). Mean luminance and chromaticity of the background were identical with those used in the grating stimuli. The subjects were placed at a distance of 1 m from the screen monitor. A central cross (1° of visual field) was used as a reference point.
For the electrophysiological experiments, the stimuli were presented in a 1-Hz square-wave contrast-reversal mode. Spatial frequencies were 0.4, 0.8, 2, 4, 8, and 10 cpd. For each spatial frequency, 8 to 10 Michelson contrasts were tested ranging from 0% to 100% after a pseudorandom presentation. For the psychophysical procedures, we added two additional spatial frequencies, 1 and 6 cpd, and performed the tests at two temporal conditions: a 1-Hz square-wave contrast reversal and a stationary stimulation mode, which we will refer to in this study as a dynamic or a static presentation, respectively.
Electrophysiological Procedure
Recordings were performed by using three gold-cup electrodes placed at Oz (active electrode), Fz (reference electrode), and Fpz (ground electrode) according to the International Society of Clinical Electrophysiology of Vision.13 The bioelectric potentials were amplified by 50,000x and online band-pass filtered between 0.5 and 100 Hz by a differential amplifier (MAS800; Cambridge Research Systems). The amplified potentials were digitized by a data-acquisition card (AS-1; Cambridge Research System) at 1 kHz of sample rate, with 12 bits of resolution, controlled by a third-part software (Optima ver. 1.4; Cambridge Research Systems).
For each stimulus, the number of sweeps recorded over time (240960 of 950 ms each) varied according to the contrast and subject amplitude response, to improve the signal-to-noise ratio. Each sweep was submitted offline to a home-made Fourier transform to extract even harmonics between 0.5 and 40 Hz, which were used to synthesize the sweep. A final waveform was obtained by averaging these synthesized sweeps. The P100 amplitude of this final VEP waveform was measured peak-to-baseline and taken as the subject response at each spatial frequency and contrast condition. The contrast threshold for each spatial frequency was estimated by fitting a regression line to the amplitude data as a function of log contrast and extrapolating it to the 0 amplitude level.
Psychophysical Procedure
Both dynamic and static conditions were tested. The spatial frequencies were presented in a pseudorandom sequence set up by software. The subjects controlled the Michelson contrast with a step of 1.15% by using a CB1 interface (Cambridge Research System) connected to a computer. The system allowed us to find their contrast threshold using the method of adjustment. The contrast value in the beginning of each trial was always suprathreshold and randomly selected by the software to avoid intertrial adaptation. For each spatial frequency, subjects contrast sensitivity was estimated from the averaged contrast threshold obtained from six individual trials.
In the dynamic condition, subjects were instructed to consider the flicker detection as an indication of visibility. In the static condition, they were instructed to consider pattern detection as a positive signal of visibility.
| Results |
|---|
|
|
|---|
|
|
|
= 0.05, and post hoc comparisons, Tukey test). Two ranges of even harmonics were identified by using this approach. When the spatial frequency was increased, there was a progressively smaller contribution of lower harmonics and a larger contribution of higher harmonics (see also Refs. 15 16 ). The even harmonics between 2 and 10 Hz had more energy at low spatial frequencies (0.4 and 0.8 cpd) than at intermediate and high spatial frequencies (4, 8, and 10 cpd) (P < 0.01). Conversely, the contribution of even harmonics to the VEP between 16 and 30 Hz was smaller at low spatial frequencies and larger at intermediate and high spatial frequencies, reaching an energy peak at 8 cpd (P < 0.05). The 12- to 14-Hz even harmonics exhibited an intermediate behavior between 2 and 10 Hz and 16 and 32 Hz, whereas the higher harmonics, 34 to 40 Hz, showed a negligible contribution to the VEP waveform that changed little with spatial frequency (P > 0.05).
|
The P100 contrastresponse function has a distinct behavior along the spatial frequency domain. For the lowest spatial frequency tested, 0.4 cpd, the P100 amplitude saturated at high contrasts (Fig. 5A) . This was also observed for 0.8 cpd in most of the individuals (n = 4, not illustrated). At intermediate spatial frequencies, 2- and 4-cpd, double-slope straight-lines were the best descriptors for the P100 contrastresponse function, so that the data points corresponding to the high and low contrasts could be best fitted by two different regression lines (Figs. 5C 5D) . At the highest spatial frequencies tested, 8 and 10 cpd, double-slope functions were also good descriptors, but the differential behavior of the P100 amplitude at low and high contrasts was less marked than at the intermediate spatial frequencies (Figs. 5E 5F) .
|
|
Comparison of Electrophysiological and Psychophysical Results
Statistical analysis was performed using one-way ANOVA (
= 0.05) and post hoc comparisons (Tukey test) to compare the spatial luminance contrast sensitivity estimated for each spatial frequency by using electrophysiological or psychophysical procedures.
There was no difference between electrophysiological contrast sensitivity and dynamic psychophysical contrast sensitivity at 0.4 cpd, but both were significantly different from the static psychophysical contrast sensitivity for this spatial frequency (P < 0.05). At 0.8, 2, and 4 cpd, there was no difference between contrast sensitivity estimated by the three procedures. At 8 and 10 cpd, the psychophysical contrast sensitivity estimated by both dynamic and static procedures were similar (P > 0.05), whereas the electrophysiological contrast sensitivity was significantly lower than both psychophysical contrast sensitivities (P < 0.01).
The correlation coefficient (r2) between mean electrophysiological CSF and mean dynamic psychophysical CSF was 0.81, whereas the r2 between mean electrophysiological CSF and mean static psychophysical CSF was 0.45 (Figs. 6A 6B , respectively).
| Discussion |
|---|
|
|
|---|
A comparison of contrast sensitivity obtained with steady state VEP elicited by sinusoidal spatial gratings at 8 Hz square-wave contrast-reversal with that obtained using psychophysical procedures and the same stimulus conditions showed similar results at all spatial frequencies tested from 1.5 to 35 cpd.1 The CSFs obtained had high peak values reaching approximately 2.5 log units at 2 cpd.
Also, a good correlation was found between steady state VEPs (10 Hz) and psychophysics using a similar procedure.17 CSF peak values ranged between 2 and 2.5 log units at 2 cpd. Both studies1 17 estimated contrast thresholds in the VEP experiments by regressions fitted to the data point and extrapolated to zero amplitude level.
In another study the visual system was stimulated with three different temporal frequencies: 6.6, 10, and 20 Hz presented either in square-wave contrast-reversal or onsetoffset modes.19 Electrophysiological results were compared with the psychophysical ones by using the same stimulus conditions, but with two psychophysical threshold criteria, flicker detection, and pattern detection. It was found that in contrast-reversal mode, VEP recording provided lower contrast sensitivity values than did psychophysical procedures, using both threshold criteria (for instance, 2 vs. 2.5 log units at 2 cpd, respectively), but both CSFs had similar shape with very little attenuation in the low-spatial-frequency range. Electrophysiological CSF obtained with contrastreversal mode was also similar in shape with onsetoffset psychophysical CSF when flicker detection criterion was used. However, when using onsetoffset mode, the electrophysiological CSF had a different shape, with strong attenuation at low spatial frequency, similar to the psychophysical CSF obtained by using pattern detection criterion.
Contrast-reversal grating was also used at a temporal frequency of 6.75 Hz to estimate electrophysiological and psychophysical CSF with 2°, 4°, and 8° grating stimuli centered on the fovea.20 Electrophysiological CSF was obtained with steady state VEP. Moreover, 8° gratings centered on the fovea with a 2° and 4° central occlusion were used to obtain parafoveal electrophysiological and psychophysical CSFs. In general, the electrophysiological contrast sensitivity was lower than the psychophysical one, and the fall-off at low and high spatial frequencies was steeper when VEP was used than when psychophysics was used.
It should be noted that these studies19 20 estimated contrast threshold with VEP by using a different approach than a straight line fitted to the data points (e.g.: Refs. 1 17 , present study). First, the signal-to-noise ratio was determined by the amplitude at the expected response frequency divided by the averaged spectral amplitude across a 3-Hz wide band centered on the second harmonic of the stimulation frequency. In recordings without stimulation, this ratio was <1.25 in 95% of attempts. The VEP was then steadily recorded changing the stimulus contrast until the signal-to-noise ratio crossed the criterion level, the threshold being defined as the contrast 2 or 4 dB below the lowest contrast that exceeded the signal-to-noise ratio criterion level.
Another technique, the so-called swept contrast VEP, combines the use of steady state VEP, visual system stimulation with a constant spatial frequency, and a quick lowering of contrast to measure contrast sensitivity; it minimizes the recording periods to retrieve responses near threshold.21 22 23 24 25 26 Generally, this technique provides lower estimates of contrast sensitivity than do psychophysical and other electrophysiological procedures. A possible explanation for that is the way the contrastresponse function is extrapolated to an estimated noise level to find the contrast threshold.
Despite several studies in which transient VEPs were used to measure contrast sensitivity in mammals (e.g., Refs. 8 27 28 29 ), the study that more directly can be compared with the present one is that by Katsumi et al.7 They measured the electrophysiological CSF by recording transient VEP at 2 Hz contrast-reversal stimulation and compared with psychophysical CSF obtained with static gratings. Psychophysical contrast sensitivity was considerably higher than electrophysiological contrast sensitivity at all spatial frequencies. The psychophysical CSF peak was 2.5 log units at 3 to 6 cpd, whereas the peak of electrophysiological CSF was 1.7 log units at the same spatial frequency range. These differences may be due to the different stimulation methods used by Katsumi et al. in electrophysiology and psychophysics (dynamic versus static stimulation in this study, respectively), as well as the smaller number of averaged sweeps used by them (64 sweeps).
Some of our results support this interpretation: The difference in the CSF tuning values was smallest when comparing CSF tuning values obtained with VEP and dynamic psychophysics. The correlation coefficient (r2) between electrophysiological and psychophysical CSF was higher when the same temporal condition was used and, at least at low spatial frequencies (< 0.8 cpd), there were no significant differences between the VEP and the dynamic psychophysical CSF.
However, one aspect seems to be common to most of the studies that compared psychophysics and electrophysiology for assessing human CSF: Most of the time electrophysiology returns lower values for contrast sensitivity than does psychophysics, never the opposite. We partially found this at high spatial frequencies (>8 cpd). One possible explanation for the psychophysical methods being more sensitive than the electrophysiological ones, might be found in Barlows Neuron Doctrine.30 At threshold, perception might rely on the activity of a few neurons, whereas a large number of active neurons may be needed to exceed the bioelectrical noise and then be recorded in the scalp.
Also, our findings support the hypothesis that the VEP results from the activity of two or more parallel pathways extending from the retina to V1. The cortical response changes in two important aspects when either the spatial frequency or contrast is changed.
First, we found that different harmonic bandwidths contribute differentially to the cortical response in the range of spatial frequency tested (Fig. 4) . This result indicates the existence of at least two different response mechanisms, partially overlapping and partially differentiated between 0.4 and 0.8 and 2 and 10 cpd. The possibility of different visual mechanisms contributing to the VEP has been explored.15 Nine consecutive wavelets have been found superimposed on the conventional VEP by using high-pass filtering (cutoff at 17 Hz). These wavelets were time locked with reversing patterns and tuned at 5 cpd. Later studies indicate that this oscillatory response (>17 Hz) and conventional VEP (<17 Hz) may have different functional roles.16 31 32
Second, we found some nonlinearities in the VEP contrastresponse functions that can be explained by the contribution of retinogeniculocortical pathways with different contrast sensitivities.33 34 35 36 Our results are consistent with a visual pathway highly sensitive to stimulus contrast, such as the magnocellular (M) pathway dominating the VEP at low contrast. Together with the M pathway, the parvocellular (P) and koniocellular (K) pathways are active at high contrasts and may cooperate to generate the VEP at high contrast. At low spatial frequencies, 0.4 to 0.8 cpd, only the M pathway seems to be relevant for the cortical response that saturates at high contrast in the same way as observed in the recording of M cells at the retina and thalamus.
The presence of two limbs in the VEP contrastresponse function was interpreted as being due to differential contribution of cells located in the foveal and parafoveal retinal regions along the range of spatial frequencies tested.1 According to this study, at low spatial frequencies (1.53 cpd) and especially at low contrasts, the VEP arises from the parafoveal region. In the present study, we found double-slope functions in a similar spatial frequency range (24 cpd), but this finding was absent at lower spatial frequencies, 0.4 to 0.8 cpd, where we found a saturation at high contrast instead.
The double-slope, amplitude-contrast function was described as a prominent and general feature of the monkey steady state VEP (4.454.6 Hz of temporal frequency; 0.2319 cpd).6 Also, the double-slope amplitude-contrast function was found in the first and second harmonics when steady state VEPs were obtained with a 6 cpd grating onsetoffset modulated at 7.5 Hz.12 These results were explained by the differential contribution of two visual mechanisms to the VEP at different contrast levels.6 12
We found these nonlinearities in all subjects tested. Figure 7 shows the normalized mean contrastresponse functions from our sample (n = 6) along the spatial frequency and contrast range that we used. It shows some of the information displayed in the Figure 5 , but this time the values represent the normalized mean amplitude for the six subjects tested, instead of the absolute amplitudes as in Figure 5 , to stress the VEP behavior when the visual system is stimulated at different spatial frequencies.14 At low spatial frequencies, 0.4 and 0.8 cpd, P100 amplitude initially shows a slow decrease when contrast is lowered and then decreases more sharply in the low-contrast range. At spatial frequencies between 2 and 10 cpd, P100 amplitude declines quickly at high contrast and then decreases more modestly at low contrast. However, it should be appreciated that the decrease rate at low contrast is very similar for all the spatial frequencies between 0.4 to 8 cpd, with the possible exception of 10 cpd, which shows a higher rate of amplitude decrease than the others. The different behavior of P100 amplitude in high and low contrasts, which was observed for all spatial frequencies tested, justifies the use of only the amplitude values obtained at low contrast to estimate contrast threshold.
|
Our results reinforce those of previous studies showing that the transient VEP is an objective and noninvasive tool for the study of human CSF. We suggest that gratings with medium to low luminance contrasts (<25% of Michelson contrast) can be used to find contrast thresholds along the spatial frequency domain, avoiding the effect of high-contrast nonlinearity.
| Footnotes |
|---|
Supported by Grant CNPq 471815/2004-7 from CNPq-PRONEX/SECTAM-FUNTEC/FADESP 1079, CAPES-PROCAD 0019/01-1, and FINEP Research Grant "Rede Instituto Brasileiro de Neurociência (IBN-Net)" 01.06.0842-00. GSS and BDG received CAPES-PROF fellowships for graduate students. MSF and LCLS are CNPq research fellows.
Submitted for publication January 6, 2007; revised February 24, 2007; accepted May 8, 2007.
Disclosure: G.S. Souza, None; B.D. Gomes, None; C.A. Saito, None; M. da Silva Filho, None; L.C.L. Silveira, None
The publication costs of this article were defrayed in part by page charge payment. This article must therefore be marked "advertisement" in accordance with 18 U.S.C.
1734 solely to indicate this fact.
Corresponding author: Luiz Carlos L. Silveira, Universidade Federal do Pará, Núcleo de Medicina Tropical, Av. Generalíssimo Deodoro 92, 66055-240 Belém-Pará, Brazil; luiz{at}ufpa.br.
| References |
|---|
|
|
|---|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |