1From the Departments of Biomedical Engineering, 2Ophthalmology, and 3Neurobiology and Physiology, Northwestern University, Evanston, Illinois.
| Abstract |
|---|
|
|
|---|
METHODS. Anesthetized cats underwent retinal argon laser photocoagulation. At least 4 weeks after treatment, PO2-sensitive microelectrodes were used to record intraretinal PO2 profiles from healed photocoagulation lesions in anesthetized cats breathing air. Histopathologic examination of the retinas was used to confirm that the photoreceptors were destroyed and that the inner retinal layers were preserved, though somewhat disorganized, as in human panretinal photocoagulation (PRP).
RESULTS. The retina and tapetum were thinner in the lesioned retina than in the nonphotocoagulated retina. Average PO2 across the inner 50% of the retina was higher (22 ± 10 mm Hg) in photocoagulated retina than in untreated retina (14 ± 7 mm Hg; P < 0.01; n = 13 cats). The minimum PO2 was also significantly higher, whereas choroidal PO2 was significantly lower in the photocoagulated retina than in untreated retina. No significant difference was found in the preretinal vitreous. After lesions, inner retinal PO2 could also be maintained above zero, even in the absence of retinal circulation.
CONCLUSIONS. Previous measurements showed increased PO2 in the preretinal vitreous of rabbits and pigs (but not cats) after photocoagulation of the outer retina. These intraretinal measurements in cats provide further evidence for a chronic increase in inner retinal PO2 in lesioned areas during air breathing.
A leading hypothesis8 9 10 of the mechanism for PRP is that the laser damages photoreceptors, which normally consume large amounts of oxygen.11 12 13 14 This leaves more of the oxygen from the choroid available to diffuse to the inner half of the retina, presumably relieving the inner retina of a possible hypoxia that is thought to be associated with capillary loss15 and that may be linked with regression of neovascularization. The second hypothesis is that photocoagulation brings to balance levels of growth factors involved in either promoting or inhibiting angiogenesis.15 During the development of diabetic retinopathy, this balance is upset and leads to neovascularization. Microarray studies of changes in gene expression in the mouse retina after laser photocoagulation show that this treatment affects genes involved in the regulation of multiple retinal processes, including those involved in angiogenesis.16 17 Of course, it is possible that the altered levels of growth factors are a direct result of the changing PO2 levels.
The evidence supporting the first hypothesis is indirect. To date, most studies have measured only preretinal PO2 after PRP. One might expect vitreal PO2 to increase, but studies in the cat retina have demonstrated increased PO2 only after 100% O2 breathing, not during air breathing.8 18 19 Increased preretinal PO2 was measured during air breathing in rabbits after PRP,20 21 but the rabbit retina has limited circulation and is metabolically different from retinas with a more complete retinal circulation.22 23 Therefore, the relevance of this finding to human PRP is unclear. Increased preretinal PO2 was also measured after photocoagulation in the eyes of miniature pigs with24 and without25 venous occlusion.
Only one intraretinal oxygen profile has been published from the cat retina after PRP, and it was recorded during hyperoxia.18 Intraretinal PO2 was also found to increase in rabbit retina in acute PRP-like lesions.26 These measurements were made on the same day the lesions were placed; hence, the long-term effects of PRP after healing of the lesion, which are more relevant for the clinical situation, were not observed. No studies have been conducted of intraretinal PO2 after PRP under normoxic conditions in vascularized retinas.
Better understanding of the mechanisms of PRP action could allow optimization of the procedure and could lead to development of less invasive and more specific treatments. In this study, we addressed whether inner retinal PO2 is increased after lesions develop that destroy the outer retina. Cat retina is similar to human midperipheral retina, where PRP is performed. Similar to the human midperipheral retina, the cat retina is rod dominated and has a moderately high neuronal density, and its nutritional needs are supplied by a combination of the choroidal and retinal circulations. We used oxygen-sensitive microelectrodes to make PO2 measurements several weeks after producing lesions in or near the area centralis, and we conducted histologic studies to verify that the lesions were similar to those made in humans.
| Methods |
|---|
|
|
|---|
Photocoagulation Procedure
All experimental procedures were conducted in accordance with the ARVO Statement for the Use of Animals in Ophthalmic and Vision Research. Adult cats of both sexes were used in the experiments. Before the laser procedure, cats were preanesthetized with ketamine (2.2–4.4 mg/kg) and butorphanol (0.4 mg/kg) and anesthetized intravenously with 0.35 mL/kg 5% sodium pentothal, or they were anesthetized intramuscularly with 11 mg/kg ketamine and 0.4 mg/kg butorphanol. Sodium pentothal (5%) was then administered intravenously as needed, and the animal was hydrated with 0.9% saline at approximately 20 mL · kg–1 · h–1. The cats temperature was monitored and maintained with a heating blanket. The pupil of one eye was dilated with topical ophthalmic solutions of 2.5% phenylephrine (Neo-Synephrine; Abbott Laboratories, Abbott Park, IL) and 1% tropicamide (Bausch & Lomb, Rochester, NY).
Retinal lesions were produced with an indirect ophthalmoscope using one argon laser (Novus Verdi; Coherent Inc., Santa Clara, CA) at Evanston Hospital or with a slit lamp using another argon laser (Ultima 2000; Coherent Inc.) at Northwestern University. Given that the damage produced with the same energy level varied from retina to retina and even with location on the same retina, we started each procedure with a low power and then increased the level until a change in retinal color was observed after a single laser pulse. This setting was then used to produce all the other lesions in the same retina. The lesions produced in this experiment were histologically similar to PRP lesions seen in human retinas. Specifically, they largely preserved the inner retina and destroyed the photoreceptors.27 We could not assess the functional state of the remaining inner retina in these experiments, and there is no evidence about its condition after PRP in humans. The laser power varied from 200 to 500 mW, and the duration was 0.1 seconds for the first photocoagulator (Novus Verdi; Coherent Inc.). For the second, (Ultima 2000; Coherent Inc.), the power varied from 500 to 800 mW, the duration varied from 0.2 seconds to 0.5 seconds, and the spot size was 500 µm.
Initially, lesions smaller than 500 µm in diameter were placed on the retina (four cats) because this is the lesion size frequently used clinically; however, in later experiments we placed lesions to cover an area of at least 2 mm in diameter because our electrodes penetrated the retina at a 45° angle. The electrode had to be far enough from the edge of a lesion that there would be only one-dimensional PO2 gradients perpendicular to the retinal surface and that the PO2 in the lesion would not be affected by the normal retina at the edge of the lesion. Lesions measuring approximately 2 mm in diameter were made by placing smaller lesions close but separated by a small distance. The goal was to produce a large confluent lesion with uniform damage. Lesions of this type were produced in 14 cats.
Color fundus photographs were taken immediately after the procedure. Animals recovered from anesthesia and were returned to the animal facility until the time of the terminal experiment, which took place at least 4 weeks after the laser procedure.
PO2 Measurements and Histology
Data were obtained from the center of the lesion and from nonphotocoagulated retina on the same section of the same eye in each animal. Intraretinal PO2 was measured in 16 animals, 13 of which were used for analysis. Data from one animal were excluded because we could not visually verify the location of the electrode. Data from two animals were excluded because photocoagulation damaged all the retinal layers.
After PO2 measurements, histologic analysis was performed on all eyes. Nine of the 18 eyes were used for measurements of retinal and tapetal thickness. Qualitatively, the retina was similar in all eyes, but nine were excluded because the histologic processing caused folding or detachment of the retina and the thicknesses were considered unreliable.
The animal preparation for PO2 measurements has been described previously.28 Briefly, the cats were initially anesthetized by intramuscular injection of ketamine (25 mg/kg) and acepromazine (0.12 mg/kg), or they were preanesthetized with intramuscular injection of butorphanol (0.4 mg/kg) and anesthetized by intravenous 5% sodium pentothal (22 mg/kg). Long-term anesthesia was provided by urethane. The cats head was immobilized in a head holder, and the eye was attached to an eye ring. The cat was paralyzed with pancuronium bromide (Pavulon; 0.2 mg · kg–1 · h–1) after surgery and was artificially ventilated. The temperature was kept at 38°C to 39°C. Electrocardiography was performed, and arterial blood pressure and blood gases were monitored throughout the experiment. Blood gases were kept in the normal range (PaO2 >90 mm Hg, PaCO2
30 mm Hg, 7.35 <pHa <7.45) by adjustments of tidal volume, and blood glucose was kept between approximately 80 and 120 mg/dL by intravenous infusions of insulin and glucose.
The pupil was dilated with 1% phenylephrine and 1% atropine. Flurbiprofen ophthalmic solution (0.03%) was applied to block prostaglandin-mediated pupillary constriction. A calibrated PO2 microelectrode was inserted into the eye through a 15-gauge needle and was sealed with a system that allowed movement of the electrode. Two 20-gauge needles containing Ag/AgCl wires were inserted into the vitreous for the recording of the vitreal electroretinogram (ERG) and as a reference for the oxygen electrode.
Double-barreled O2-sensitive microelectrodes were fabricated as previously described.29 One barrel was used to record oxygen, and the second, voltage-sensitive, barrel was used to record the intraretinal ERG.
Intraretinal PO2 measurements were made in normal and lesioned areas of each retina. The retina was penetrated in 3-µm steps. The intraretinal ERG was recorded every 30 to 60 µm in response to diffuse light flashes 2.5 seconds in duration and at an illumination just below b-wave saturation. The choroid/retinal boundary was identified when a transepithelial potential across the retinal pigment epithelium (RPE) was recorded (a negative shift in the voltage trace). In lesioned areas of the retina, the transepithelial potential was usually not present, probably because of the damage to the RPE, so the choroid/retinal boundary was considered to be the point at which PO2 no longer increased. After reaching the choroid, the electrode was withdrawn from the dark-adapted retina at 2 µm/s, generating a PO2 profile across the retina. During withdrawal, the vitreoretinal interface was identified as the location where the ERG recorded by the microelectrode was the same as the vitreal ERG. In the lesioned part of the retina, the ERG was absent, and the end of the profile was determined as described in the Data Analysis section.
Vitreal and microelectrode voltage signals were recorded with unity gain amplifiers (M4A and M707A; WPI, Sarasota, FL). They were referenced to an Ag/AgCl scalp electrode. Current from the oxygen electrode was recorded with a picoammeter (model 614; Keithley Instruments, Cleveland, OH). The output voltage from the picoammeter was fed through an amplifier to a chart recorder and a computer.
In three animals, a retinal artery was mechanically occluded at the time of the acute procedure. A 0.7-mm diameter glass probe with a 0.5- to 0.7-mm ball at the tip was pressed on a small superior branch artery, supplying a lesioned part of the retina, where the vessel arose from the optic disc.30 The occluder was inserted into the eye through a 19-gauge needle, which was held in a manipulator that allowed the positioning of the occluder over the desired vessel. The occluder was advanced with a hydraulic microdrive (model 1207S; David Kopf Instruments, Tujunga, CA). The occlusion was confirmed by visual observation of gaps in the blood in the vessel and by absence of the ERG b-wave in a nonlesioned area.
Before occlusion, profiles were collected from nonphotocoagulated and lesioned parts of the retina. After the artery was occluded, another set of profiles was obtained from the same area of the lesion.
Experiments were terminated by injection of pentobarbital (120 mg/kg), and eyes were fixed in 10% formalin or Davidson fixative and embedded in paraffin. Four-micrometer sections were stained with hematoxylin and eosin, visualized with light microscopy, and photographed. The sections were separated by 50 to 100 µm.
Data Analysis
Histology.
Fundus photographs were used to localize the lesions in histologic sections. All the lesions were analyzed for damage to the retina; in some, the lesion width, thickness of the tapetum, and thickness of the retina were measured. The same parameters were also measured for the nonphotocoagulated retina adjacent to the lesion on the same slide for comparison. On each slide, each parameter was measured three times. Parameters were averaged for each slide, and then the values from all slides were averaged for each lesion. No corrections were made for tissue alterations resulting from processing because paired t-tests were used for statistical analysis.
PO2 Profiles.
The length of the PO2 profile was based on two boundaries, the choroidal/retinal boundary and the retinal/vitreal boundary. The choroidal/retinal boundary was designated where the PO2 changed during withdrawal from its constant value in the choroid to a steep decrease in the outer retina. The retinal/vitreal boundary was based on the ERG, as described. When the electrode was in the lesioned retina, the intraretinal ERG was absent, and it was not possible to determine the retinal thickness by this method. For those profiles, histologic data were used to determine retinal thickness. The thicknesses of the nonphotocoagulated retina (TNH) and the lesioned retina (TLH) were measured. The ratio TLH/TNH then described the relative thicknesses of the two regions. To determine the thickness of the lesioned retina in PO2 profiles, TLP, the above ratio was multiplied by the average thickness of the nonphotocoagulated retina determined from the profiles from the normal part of the retina, TNP, as TLP = TNP x TLH/TNH.
Average inner retinal PO2, minimum PO2, and choroidal PO2 were calculated for each profile, and the values for all profiles corresponding to a particular lesion were averaged. The average inner retinal PO2 was calculated for the inner 50% of the nonphotocoagulated retina. For photocoagulated retina, the inner retina was more than 50% of the total, but, because of the debris or scar layer, the inner retina was generally less than 100% of the retina. To bracket the value for the actual inner retina, the average PO2 was calculated for the inner 50% and for 100% of the lesioned retina.
Paired t-tests were conducted to compare control and lesioned areas. Differences were considered significant for P < 0.05. Data collected from small and large lesions were tested together and are presented in the same figures.
| Results |
|---|
|
|
|---|
|
Histology
Most of the photocoagulation damage was confined to the outer retina (Fig. 2) , which was destroyed. In some cases, the outer retina was replaced by a fibrous glial scar of variable thickness. This glial scar was usually thicker in smaller lesions (Fig. 2A) . In most cases, regardless of whether there was a glial scar, the inner retina was closer to the choroid than in undamaged retina. The inner retina was primarily preserved, but sometimes the inner nuclear layer was disorganized. Because the outer retina was destroyed, the retinal thickness decreased significantly in the photocoagulated areas (141 ± 33 µm) compared with the nonphotocoagulated areas (192 ± 40 µm; P = 0.00002; n = 20 lesions from 9 cats, paired t-test; Fig. 3A) . Only in cat 345 did it appear that the retina increased in thickness after photocoagulation because the glial scar was thicker in this cat. The absolute retinal thickness might have been distorted by processing, but the relative values are reliable because the measurements for control and lesioned retina were made on the same slide.
|
|
Intraretinal PO2
PO2 Profiles with Intact Retinal Circulation.
In nonphotocoagulated retina, PO2 was highest in the choroid, which is an O2 source (Fig. 4A) . Oxygen diffuses through the photoreceptor outer segments and reaches a minimum around the photoreceptor inner segments, which are the region of highest O2 consumption. Frequently, O2 also diffuses toward the outer retina from the inner retina, which in general supplies approximately 10% of the oxygen for the photoreceptors in the dark-adapted retina.31 Consumption in both the photoreceptor outer segments and the outer nuclear layer is negligible.13 As a result, the PO2 profile is a straight line through both these layers. In the inner retina, local PO2 maxima represent the retinal circulation.
|
Several parameters were obtained from the profiles and compared across lesioned and normal retina. The average PO2 was calculated for the inner 50% of normal retina and for both 100% and the inner 50% of the lesioned retina (Fig. 5) . Based on histologic examination, the thickness of the inner retina in the lesion typically fell between those two values.
|
The minimum PO2 for each animal, averaged across profiles, is shown in Figure 6 . In untreated retina, the minimum was low because of the high oxygen consumption rate of the inner segment layer. In the lesioned part of the retina, the photoreceptors were destroyed, so the minimum was significantly higher (17 ± 8 mm Hg) than in the untreated part of the retina (3 ± 4 mm Hg; P << 0.001; n = 13 cats).
|
|
PO2 Profiles with Occluded Retinal Circulation.
In clinically advanced diabetic retinopathy requiring PRP, widespread vascular damage can lead to significant capillary dropout.33 34 We tried to mimic the clinical situation of reduced inner retinal circulation by investigating the more severe case of occluding a retinal artery that supplied part of the retina with a photocoagulation lesion.
We attempted to make measurements in the lesion after arterial occlusion in three animals and were successful in two. We had to produce lesions in an area of the retina supplied by a single small retinal artery that was not paired with a vein at the optic disc so that we could cut off the retinal circulation without producing the hemorrhages that usually occur with a venous occlusion. This was difficult to achieve because the artery decreased in diameter after placement of lesions, presumably because the metabolic needs of the lesioned tissue were supplied to a greater extent by the choroid and because the blood flow through this retinal arteriole was reduced.
Figure 8 shows profiles from different parts of the retina with and without occluded circulation. The profiles from the lesion without retinal circulation had a linear slope at the beginning of the profile, probably corresponding to the debris layer. They also had more curvature than the profiles collected from the lesioned part of the retina with intact retinal circulation. Diffusion theory predicts that this curvature corresponds to the consumption of oxygen. This was not visible in the profiles with intact retinal circulation because the supply and consumption of oxygen overlapped in space. The minimum PO2 in the profiles from the lesion without retinal circulation was lower than in the profiles from the lesioned part of the retina with intact circulation, but it was higher than 0 mm Hg, the value that has been observed previously in nonphotocoagulated retina with an occluded circulation.30
|
|
| Discussion |
|---|
|
|
|---|
Results from the measurements during occlusion provide further support for the hypothesis that PRP relieves inner retinal hypoxia because in lesioned retina, the choroidal supply alone was able to keep average inner retinal PO2 at approximately 10 mm Hg. The presence of a lesion is required for this. Without a lesion, the inner retinal PO2 is essentially zero after occlusion.30
Previous studies, in which intraretinal PO218 45 or preretinal PO28 18 45 was measured in monkeys and cats, found increased PO2 over the photocoagulation lesion only when the animals were breathing 100% O2 and no difference between lesion and control under air breathing. There are several possible explanations for the difference in these studies and our findings. First, the preretinal and retinal PO2 vary across the retina and preretinal vitreous. The measurements reported or used for statistics in previous studies were made at a single point within the retina45 or vitreous, whereas our inner retinal values are averages across the whole thickness of the inner retina. Second, preretinal O2 comes from the retinal circulation, but it reflects oxygenation of the innermost part of the retina, whereas our profiles and the values used for statistical analysis are spatial averages across the retina. The effect of choroidal oxygenation when an animal is breathing air should be largest in the deeper part of the inner retina and smallest at the vitreous. As shown in the results, measurements in the preretinal vitreous in our data did not show significant differences between control and photocoagulated retina. Third, the studies cited were not always successful in recording data from photocoagulated and nonphotocoagulated regions of the retina within the same animal; hence, the number of animals was small.8 45 In one study, the number of measurements rather than the number of animals was used for statistical analysis,18 whereas all our statistics were calculated using paired t-tests. Features of the present study allowed us to detect differences that might have been present in earlier studies but that were obscured by the measurement techniques.
Histologic analysis showed that photocoagulation damaged the photoreceptors and often decreased the distance between the choroid and the inner retina. Both factors contributed to improved oxygen delivery to the inner retina. It is possible that a further increase in inner retinal oxygenation resulted from decreased inner retinal metabolism after the lesion The inner retinal oxygen consumption in two cats for which it was possible to measure this was <1 mL · 100g–1 · min–1, which was smaller than that the average value of 3.5 ± 1.7 mL · 100g–1 · min–1 reported for nonphotocoagulated retina with occluded retinal artery.35 This is suggestive of damage to the inner retina, but that conclusion is tenuous for two reasons. First, the number of animals in which modeling could be performed was small (n = 2). Second, the statistics are further weakened because we were unable to collect profiles from a region with occlusion but without lesions in the same retinas; therefore, the comparison is with data obtained previously. Based on evidence in models of photoreceptor degeneration, we would not have expected the metabolism of the inner retina to change solely because the photoreceptors were missing.36 46 47 However, the loss of photoreceptors in a retinal degeneration model and the destruction of the photoreceptors with a laser, which may cause some damage or disorganization of the inner retina, are different situations. If the values obtained here are indeed lower than inner retinal oxygen consumption in the normal retina, it is likely that the lesioned human retina is similar. No other information is available about any of the functional aspects of the inner retina in humans with PRP or in animal models of PRP.
Another important finding of this study was that photocoagulation consistently decreased choroidal PO2 in the lesion. Although one case study reported damage to the choroid with PRP,48 in general little attention has been paid to the effect of PRP on the choroid. This is surprising because after capillary loss in diabetic retinopathy, the choroid must be the main source of O2. The damage to the choriocapillaris could be inferred from the histologic sections, where the tapetum, through which the choriocapillaris runs, was damaged. Investigation of the effect of photocoagulation on choroidal blood flow by means of indocyanine green dye and microsphere imaging in a separate study (Linsenmeier RA, et al. IOVS 2007;48:ARVO E-Abstract 4167) revealed directly that photocoagulation severely damaged the choriocapillaris. The loss of choriocapillaris in that study was so great that we think the oxygen in the lesioned retina must have come, at least partially, from the larger vessels of the choroid, which remained intact.
Although the cat area centralis is a good model of human peripheral retina, a few important differences might affect the retinal absorbance of laser energy. The cat has a tapetum, and the retinal pigment epithelium (RPE) in this region is nonpigmented, whereas the human retina has no tapetum and a pigmented RPE, which is thought to absorb the energy delivered by the laser.49 50 In cat, this energy is not absorbed by the nonpigmented RPE, but it is probably absorbed by the choroidal melanocytes or by the photoreceptors. For the same laser energy, this might result in different damage to the tissue and different intraretinal conditions, but we have reported data only for lesions in which the outer retina was destroyed and the inner retina was largely intact; this is the same histologic appearance as in human PRP. Because of the differences in cat and human retina, it is possible that the same retinal lesions in cat and human would affect the choriocapillaris differently, but we do not believe this is likely. If the RPE is the major absorber in human retina, it seems likely that the adjacent choriocapillaris is damaged in humans as well.
Most of the results presented here were from measurements made in lesions much larger than those produced in clinical PRP. It is possible that lesion size affects intraretinal PO2 by producing different damage to the tissue; however, we made some measurements in smaller lesions that were consistent with the findings in larger lesions, except for cat 345. In this cat, however, histologic analysis showed that the inner retina was further away from the choroid than in most other animals because of the presence of a thick glial scar (Fig. 2A) , which decreased the amount of oxygen delivered to the inner retina.
In this study we focused on inner retinal oxygenation directly over the lesion. If one conceives of a lesioned region as being a cylinder, with the laser-destroyed photoreceptors at one end of the cylinder and a relatively undamaged inner retina at the other end, it can be seen that there is increased oxygenation within the cylinder. An important question is whether there is significant diffusion of oxygen out of this cylinder that might increase oxygenation in adjacent, undamaged tissue. We could not address this question experimentally because it was difficult to locate the electrode precisely at the edge of a lesion. Such measurements would have been difficult to interpret in any case because they provide only one-dimensional information about O2 gradients, whereas at the edge of the lesion the O2 gradients are expected to be two dimensional. We addressed the question of O2 diffusing out of the lesioned region by mathematical simulations that will be reported separately. However, modeling suggests that the beneficial effect of the lesion extends for only approximately 70 µm lateral to the photocoagulated retina.51
This study shows that PRP increases PO2 levels in the retina, but it does not exclude the possibility that some of the benefit of PRP results from the destruction of cells producing angiogenic factors. It is possible that destruction of those cells combined with increased intraretinal PO2 is responsible for the effectiveness of the treatment. Increased PO2 should decrease production of angiogenic factors. Additionally, no studies have addressed what happens to substrates or metabolites other than oxygen after PRP. Delivery of other substrates and clearance of waste is likely to be impaired in diabetic retinopathy and could be improved after PRP by bringing the inner retina closer to the choroidal circulation.
| Acknowledgements |
|---|
| Footnotes |
|---|
Submitted for publication January 20, 2007; revised April 19, August 10, and September 6, 2007; accepted November 20, 2007.
Disclosure: E. Budzynski, None; J.H. Smith, None; P. Bryar, None; G. Birol, None; R.A. Linsenmeier, None
The publication costs of this article were defrayed in part by page charge payment. This article must therefore be marked "advertisement" in accordance with 18 U.S.C.
1734 solely to indicate this fact.
Corresponding author: Robert A. Linsenmeier, Department of Biomedical Engineering, Northwestern University, 2145 Sheridan Road, Evanston, IL 60208-3107; r-linsenmeier{at}northwestern.edu.