1From the Centre for Vision Research, Department of Ophthalmology, Westmead Millennium Institute, University of Sydney, Sydney, Australia; the 2Centre for Eye Research Australia, University of Melbourne, Melbourne, Australia; and the 3Singapore Eye Research Institute, Yong Loo Lin School of Medicine, National University of Singapore, Singapore.
| Abstract |
|---|
|
|
|---|
METHODS. The Sydney Childhood Eye Study (SCES) examined 1740 6-year-old children from 34 randomly selected Sydney schools during 2003 and 2004. Retinal arteriolar and venular calibers (central retinal arteriolar [CRAE] and central retinal venular [CRVE] equivalents) were measured from retinal photographs by a standardized computer-assisted method. Associations of retinal vascular caliber with ethnicity and iris color were analyzed.
RESULTS. Of the total participants, 1612 (92.6%) had gradable retinal photographs. CRAE and CRVE were normally distributed, with means (SD) of 163.2 (14.0) and 227.3 (18.3) µm, respectively. Both arteriolar and venular calibers were substantially wider in the East Asian than in the Caucasian children (CRAE, 171.5 µm vs. 160.5 µm; and CRVE, 240.5 µm vs. 222.4 µm; P < 0.0001 for both comparisons). Among the Caucasian children, darker iris color was associated with wider arteriolar and venular caliber: CRAE increased from 157.5 µm in blue eyes to 169.2 µm in dark brown eyes (P for trend < 0.0001), and CRVE increased from 218.4 µm in blue eyes to 230.0 µm in dark brown eyes (P for trend < 0.0001). Among the children with dark brown eyes, there was no significant difference in CRAE between the Caucasian and the East Asian children, although mean CRVE was still approximately 10 µm wider in the East Asian than in the Caucasian children.
CONCLUSIONS. Retinal vessel caliber was wider in the children of East Asian ethnicity. This difference was explained principally by darker iris color. Retinal pigmentation, as approximated by iris color, could be an important source of error in the measurement of retinal vessel caliber. If confirmed, this may affect comparisons of retinal vessel caliber between subjects with different ethnic backgrounds.
There is increasing evidence that retinal vascular caliber may vary between racial and ethnic groups. In the Multi-Ethnic Study of Atherosclerosis (MESA), the blacks and Hispanics had larger retinal arteriolar and venular caliber than the whites and Chinese, despite adjustment for cardiovascular risk factors.5 The Singapore Cohort Study of Risk Factors for Myopia (SCORM) also found significant differences in retinal vascular caliber in Malay, Indian, and Chinese children.10 The underlying reasons for these racial and ethnic differences are unclear and were thought possibly to reflect variations in levels and susceptibility to vascular risk factors (e.g., blood pressure), anthropometric and ocular biometry measures (e.g., axial length), and/or genetic factors.11 12
We now hypothesize that variations in contrast between retinal background color and the vessel edge affect retinal vessel caliber measurements from fundus photographs, and that variations in retinal pigmentation may explain some of the observed racial and ethnic differences. Figure 1 shows fundus photographs from two SCES children. The top photograph is from a blue-eyed Caucasian child and the middle photograph is from a dark brown-eyed East Asian child. The graph shows the pixel density curves over the marked arterioles. The contrast between the vessel edge and retinal background was greater in the blue eye than in the dark brown eye. The slope of the pixel density curve at the vessel edge in the blue eye was also steeper than that in the dark brown eye. As the measurement takes the mid-half value from the curve,13 the gentler slope would give a wider absolute value for this measure.
|
| Methods |
|---|
|
|
|---|
Demographic Data
Demographic data were obtained from a comprehensive 193-item questionnaire sent to parents. Questions covered topics including socioeconomic status, medical and ocular history, and birth history (including birth weight and gestational age). Each childs ethnicity was determined from the ethnicity of both parents. Ethnic groups represented were European Caucasian, East Asian, South Asian (Indian/Pakistani/Sri Lankan), African, Melanesian/Polynesian, Middle Eastern, Indigenous Australian, and South American.
Ocular Examination and Retinal Photography
Iris color was assessed from the undilated pupil of each eye and graded by the observer as blue, hazel-green, tan-brown, or dark brown.
Axial length was measured before cycloplegia with an optical biometer (IOLMaster; Carl Zeiss Meditec, Oberkochen, Germany), using dual-beam partial-coherence interferometry (PCI).16 The average of five measurements was used for analysis.
Cycloplegia was induced by instilling cyclopentolate 1% and tropicamide 1%, 2 drops each, separated by 5 minutes. Phenylephrine 2.5% was also instilled in a small proportion of children, to achieve adequate mydriasis (
6 mm). Autorefraction (RK-F1 autorefractor/keratometer, Canon, Tokyo, Japan) was performed 25 to 30 minutes after the last drop. Five autorefractions were performed automatically. The median measurement obtained by the instrument was used for analyses.
Mydriatic 60° digital photographs of the optic disc and macula of both eyes were taken with a fundus camera (model 60UVI-D10; Canon). Methods used to measure and summarize retinal vascular caliber from the digital retinal photographs have been described elsewhere.1 17 18 Briefly, a computer imaging program (IVAN; University of Wisconsin, Madison, WI) was used to measure the caliber of all retinal vessels located one half to one disc diameter from the optic disc margin in the digital retinal photograph. Using the Knudtson-Hubbard formula,3 we summarized these measurements as central retinal arteriolar (CRAE) and central retinal venular equivalents (CRVE), representing the average arteriolar and venular calibers in the examined eye, respectively. A single grader (BT), masked to participant characteristics, performed all retinal measurements.18 High correlation between the right and left eyes in retinal vascular caliber measurements has been reported.19 Data from the right eyes were used. High intra- and intergrader reproducibility of the retinal vascular measurements obtained with a computer-based program has been reported.1 2
Anthropometric and Blood Pressure Measurements
Anthropometric measurements including height, weight, and waist circumference, were collected for each child.18 Height without shoes was measured with a freestanding height rod (model 220; Seca, North Rocks, NSW, Australia). Weight was measured with an electronic scale (model TBF-300; Tanita, Tokyo, Japan). Body mass index (BMI) was calculated as weight in kilograms divided by height in meters squared.
Sitting blood pressure and heart rate were measured in the right arm with an oscillometric blood pressure recorder (HEM-907; Omron, Sydney, NSW, Australia).18 After the child had 10 minutes of quiet rest, a single measure of blood pressure was taken using an appropriately sized cuff. Mean arterial blood pressure (MABP) was calculated as one third of the systolic (SBP) plus two thirds of the diastolic blood pressure (DBP).
Statistical Analysis
Analyses were performed for the right eye data (SAS ver. 9.1; SAS Institute, Cary, NC).
2 and t-tests were used to compare selected characteristics between subgroups. Multivariate adjusted means for retinal vascular caliber in subgroups were calculated using analysis of covariance. Mixed models were used for additional adjustment for cluster-sampling effects.
| Results |
|---|
|
|
|---|
Table 1 presents selected characteristics of the study population stratified by the two main ethnic groups. The East Asian children were younger and shorter and had lower BMI, lower birthweight, and more myopic refraction than did the European Caucasian children. Almost all (99.3%) of the East Asian children and only 5.5% of the Caucasian children had dark brown iris color. There was no difference in SBP, DBP, and axial length between these two ethnic groups.
|
|
|
10 µm CRAE, 20 µm CRVE) observed between the East Asian (mean CRAE, 171.5 µm; mean CRVE, 240.5 µm) and Caucasian children (mean CRAE, 160.5 µm; mean CRVE, 222.4 µm), P < 0.0001 for both calibers, after multivariate adjustment. Among the European Caucasian children, darker iris color was associated with wider arteriolar and venular caliber (Table 3) . Multivariate adjusted mean CRAE increased from 157.5 µm in blue eyes to 169.2 µm in dark brown eyes (P for trend < 0.0001). Multivariate adjusted mean CRVE increased from 218.4 µm in blue eyes to 230.0 µm in dark brown eyes (P for trend < 0.0001). The findings were similar when children from all ethnic groups were included (Table 3) .
|
|
| Discussion |
|---|
|
|
|---|
10 µm difference in the mean arteriolar and venular caliber between blue eyes and dark brown eyes). Thus, we suggest that the racial–ethnic variation in retinal vessel caliber is principally explained by darker iris color, a proxy for retinal pigmentation.
We further tested our hypothesis using data from the Blue Mountains Eye Study (a population that included 98% European Caucasian adults aged 49+ years) and found similar association between iris color and retinal vascular caliber, although a different computer program, Retinal Analysis,13 was used for the measurements. Both retinal arteriolar and venular calibers were significantly wider (
5 µm difference for both) in persons with dark brown irises than in those with blue irises (P < 0.0001 after controlling for age, gender, BMI, smoking and MABP; Rochtchina E, unpublished data, 2007).
Our study is consistent with and provides a new explanation for the findings in two other studies that examined racial and ethnic differences in retinal vascular caliber. In the MESA study population, the African-Americans and Hispanics, who have darker fundus pigmentation, were reported to have wider mean arteriolar and venular calibers compared with that of the whites and Chinese. Also, the Chinese had wider mean venular caliber than did the whites.5 The SCORM data showed that both retinal arterioles and venules were wider in the Malay or Indian children (who have somewhat darker retinal pigmentation) than in the Chinese children, even after adjustment for age, gender, refraction, and other factors.10 Darker iris color correlates highly with non-Caucasian ethnicity. In our sample, among children with dark brown eyes, only 11% were of European Caucasian ethnicity. We therefore propose that the observed ethnic differences in retinal caliber are likely to be at least partly explained by the different retinal pigment background indicated by various iris colors. Our findings from subgroup analyses of children with dark brown iris color support this hypothesis. Among children with dark brown eyes, we found no difference in the mean arteriolar caliber between European Caucasian and East Asian children. The difference in the mean venular caliber remained significant, with a reduced magnitude (Table 4) .
Our study suggests that a higher level of retinal pigmentation (represented by darker iris color) may reduce the contrast between the background and retinal vessels, making the vessel edge harder to detect with the semiautomatic computer program. This seems likely to result in measurements that exceed the true boundary of the vessel. We are currently planning a fluorescein angiographic comparison study for investigation of this hypothesis.
We should consider alternative hypotheses. It is possible, for example, that the observed relationship between retinal vessel caliber with iris color is in part attributable to genetic differences.20 However, we have no means to determine whether there is a genetic influence.
In summary, darker iris color was found to be associated with wider retinal vascular caliber, as measured with a standardized semiautomated computer program from digital retinal images. Retinal pigmentation, as approximated by iris color, could be an important source of error in the measurement of retinal vessel caliber, and this measurement error may largely explain the observed ethnic differences in retinal vessel caliber. If this measurement error is confirmed by other studies, the effect of contrast may have to be taken into account when comparing retinal vessel caliber among subjects with different ethnic backgrounds.
| Footnotes |
|---|
Submitted for publication February 6, 2007; revised April 4, 2007; accepted February 15, 2008.
Disclosure: E. Rochtchina, None; J.J. Wang, None; B. Taylor, None; T.Y. Wong, None; P. Mitchell, None
The publication costs of this article were defrayed in part by page charge payment. This article must therefore be marked "advertisement" in accordance with 18 U.S.C.
1734 solely to indicate this fact.
Corresponding author: Paul Mitchell, Centre for Vision Research, Department of Ophthalmology University of Sydney, Westmead Hospital, Hawkesbury Rd., Westmead, NSW, 2145, Australia; paul_mitchell{at}wmi.usyd.edu.au.